Deck 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating

ملء الشاشة (f)
exit full mode
سؤال
Screwless push-in terminals (i.e., back wiring holes) on receptacles are listed only for use with what type of branch-circuit conductor?
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
On isolated ground receptacles, the metal yoke ____ integrally bonded to the equipment grounding terminal of the receptacle.

A) is
B) is not
سؤال
When using individual conductors in raceway, which insulation color is NOT permitted for the grounded conductor (neutral)?

A) gray
B) white
C) green with three white stripes
سؤال
Snap switches with nonmetallic yokes (straps) have a terminal for the equipment grounding conductor. Using this type of switch provides a means for grounding ____ faceplates when nonmetallic boxes are used.

A) oversize (goof)
B) metal
C) nonmetallic
D) recessed
سؤال
"T"-rated snap switches are intended for what application?
سؤال
The grounded (identified) conductor of 6 AWG or smaller must have an outer finish that is ____.

A) white
B) gray
C) three continuous white stripes
D) any of the above
سؤال
When receptacles or switches have No. 6-32 screws secured to them with small pieces of cardboard, these pieces of cardboard must be ____ when the wiring device is installed in a metal outlet box.

A) left in place
B) removed
C) replaced with metal lock washers
D) none of these
سؤال
From how many locations does four-way switching allow a lighting outlet to be controlled?
سؤال
Describe what NEC 250.148 requires to maintain the continuity of the equipment grounding path.
سؤال
Name at least four kinds of lighting switches.
سؤال
When terminating a receptacle, the white (grounded) conductor is always connected to the ____________________-colored terminal, and the phase (hot) conductor is always connected to the ____________________-colored terminal.
سؤال
The conductors that run between a switched outlet and the switch controlling the outlet are called a(n) ____________________.
سؤال
Phase conductors 6 AWG and smaller ____ permitted to be re-identified as equipment ground conductors using green paint, tape, or other effective means.

A) are
B) are not
سؤال
The NEC requires that switching be done only in ____ conductors.

A) ungrounded
B) designated
C) black
D) red
سؤال
When is a reidentified white conductor NOT permitted?
سؤال
In older existing installations, where an equipment ground does not exist in a metal switch box that is located within reach of a conductive floor such as tile or cement, NEC 404.9(B) requires the use of what kind of faceplate?
سؤال
To avoid inductive heating in metallic raceways, the NEC requires that ____.

A) all circuit conductors be run in the same raceway
B) the grounded (neutral) conductor be oversized
C) the equipment grounding conductor be bonded to the raceway
D) none of these
سؤال
All 125-volt, 15- and 20-ampere receptacles in a dwelling are required to be ____.

A) tamper resistant
B) AFCI protected
C) GFCI protected
D) weather resistant
سؤال
Alternating current, general-use snap switches are UL-listed to control motors rated up to ____ horsepower.

A) 1/2
B) 3/4
C) 2
D) as marked on the switch
سؤال
The long slot on a 15-ampere, 125-volt, receptacle is the ____ conductor.

A) grounded
B) phase "hot"
C) equipment-grounding
D) traveler
سؤال
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
14 AWG copper
سؤال
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
12 AWG copper
سؤال
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
10 AWG copper
سؤال
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
a.Equipment grounding conductor
b.Hot (phase) conductor
c.Grounded (white) conductor
Silver-colored screw
سؤال
Match the following switch types with the correct number of terminals for each.
a.Two terminals
b.Four terminals
c.Three terminals
Three-way switch
سؤال
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
a.Equipment grounding conductor
b.Hot (phase) conductor
c.Grounded (white) conductor
Green hexagonal screw
سؤال
Match the following switch types with the correct number of terminals for each.
a.Two terminals
b.Four terminals
c.Three terminals
Four-way switch
سؤال
A 4-way switch does not have "ON" and "OFF" markings. Four-way switches are connected to the "____________________" between two 3-way switches. One 3-way switch is fed by the ____________________; the other 3-way switch is connected to the load.
سؤال
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
The common point on a wye-connected polyphase system or the mid-point on a single phase system is the _________________________.
سؤال
Match the following switch types with the correct number of terminals for each.
a.Two terminals
b.Four terminals
c.Three terminals
Single-pole switch
سؤال
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
a.Equipment grounding conductor
b.Hot (phase) conductor
c.Grounded (white) conductor
Brass-colored screw
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/31
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 5: Conductor Identification, Switch Control of Lighting Circuits, Bondinggrounding of Wiring Devices, Induction Heating
1
Screwless push-in terminals (i.e., back wiring holes) on receptacles are listed only for use with what type of branch-circuit conductor?
These terminals are used with solid 14 AWG copper conductors.
2
On isolated ground receptacles, the metal yoke ____ integrally bonded to the equipment grounding terminal of the receptacle.

A) is
B) is not
B
3
When using individual conductors in raceway, which insulation color is NOT permitted for the grounded conductor (neutral)?

A) gray
B) white
C) green with three white stripes
C
4
Snap switches with nonmetallic yokes (straps) have a terminal for the equipment grounding conductor. Using this type of switch provides a means for grounding ____ faceplates when nonmetallic boxes are used.

A) oversize (goof)
B) metal
C) nonmetallic
D) recessed
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
5
"T"-rated snap switches are intended for what application?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
6
The grounded (identified) conductor of 6 AWG or smaller must have an outer finish that is ____.

A) white
B) gray
C) three continuous white stripes
D) any of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
7
When receptacles or switches have No. 6-32 screws secured to them with small pieces of cardboard, these pieces of cardboard must be ____ when the wiring device is installed in a metal outlet box.

A) left in place
B) removed
C) replaced with metal lock washers
D) none of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
8
From how many locations does four-way switching allow a lighting outlet to be controlled?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
9
Describe what NEC 250.148 requires to maintain the continuity of the equipment grounding path.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
10
Name at least four kinds of lighting switches.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
11
When terminating a receptacle, the white (grounded) conductor is always connected to the ____________________-colored terminal, and the phase (hot) conductor is always connected to the ____________________-colored terminal.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
12
The conductors that run between a switched outlet and the switch controlling the outlet are called a(n) ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
13
Phase conductors 6 AWG and smaller ____ permitted to be re-identified as equipment ground conductors using green paint, tape, or other effective means.

A) are
B) are not
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
14
The NEC requires that switching be done only in ____ conductors.

A) ungrounded
B) designated
C) black
D) red
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
15
When is a reidentified white conductor NOT permitted?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
16
In older existing installations, where an equipment ground does not exist in a metal switch box that is located within reach of a conductive floor such as tile or cement, NEC 404.9(B) requires the use of what kind of faceplate?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
17
To avoid inductive heating in metallic raceways, the NEC requires that ____.

A) all circuit conductors be run in the same raceway
B) the grounded (neutral) conductor be oversized
C) the equipment grounding conductor be bonded to the raceway
D) none of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
18
All 125-volt, 15- and 20-ampere receptacles in a dwelling are required to be ____.

A) tamper resistant
B) AFCI protected
C) GFCI protected
D) weather resistant
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
19
Alternating current, general-use snap switches are UL-listed to control motors rated up to ____ horsepower.

A) 1/2
B) 3/4
C) 2
D) as marked on the switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
20
The long slot on a 15-ampere, 125-volt, receptacle is the ____ conductor.

A) grounded
B) phase "hot"
C) equipment-grounding
D) traveler
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
21
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
14 AWG copper
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
22
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
12 AWG copper
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
23
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
10 AWG copper
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
24
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
a.Equipment grounding conductor
b.Hot (phase) conductor
c.Grounded (white) conductor
Silver-colored screw
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
25
Match the following switch types with the correct number of terminals for each.
a.Two terminals
b.Four terminals
c.Three terminals
Three-way switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
26
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
a.Equipment grounding conductor
b.Hot (phase) conductor
c.Grounded (white) conductor
Green hexagonal screw
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
27
Match the following switch types with the correct number of terminals for each.
a.Two terminals
b.Four terminals
c.Three terminals
Four-way switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
28
A 4-way switch does not have "ON" and "OFF" markings. Four-way switches are connected to the "____________________" between two 3-way switches. One 3-way switch is fed by the ____________________; the other 3-way switch is connected to the load.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
29
Specify the maximum overcurrent protection permitted for following the circuit conductor sizes:
a.15 amperes
b.20 amperes
c.30 amperes
The common point on a wye-connected polyphase system or the mid-point on a single phase system is the _________________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
30
Match the following switch types with the correct number of terminals for each.
a.Two terminals
b.Four terminals
c.Three terminals
Single-pole switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
31
Receptacles have several screw terminals for the attachment of circuit conductors. Match the following screws with their intended conductor.
a.Equipment grounding conductor
b.Hot (phase) conductor
c.Grounded (white) conductor
Brass-colored screw
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.