Deck 32: Standby Power Systems

ملء الشاشة (f)
exit full mode
سؤال
Where the normal power main service disconnecting means is located inside of the home, some electrical inspectors will require that a disconnect for the standby power from the generator be installed near the back door of the home.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Because generators produce a certain level of ____________________ when running, you will want to check with your building authorities to make sure the generator you choose is in compliance with local codes that might be applicable.
سؤال
For home installations, transfer switches may be ____________________ or double-pole, double throw (DPDT), depending on how the type of system is being installed.
سؤال
How must a transfer switch connected to the line side of the main service disconnect be listed?
سؤال
Standby power conductors and normal power conductors must not be run in the same raceway or enclosure.
سؤال
Actual wiring of a typical standby generator consists of ____ ungrounded conductor(s) and one grounded "neutral" conductor.

A) one
B) two
C) three
D) four
سؤال
What must a transfer switch must do in such a way that there is no feedback from the generator to the utility system?
سؤال
The conductors that run from the standby generator to the transfer switch and to the generator panelboard that contains the branch-circuit overcurrent devices shall be sized not less than ____ percent of the generator's nameplate current rating.

A) 80 percent
B) 115 percent
C) 125 percent
D) 150 percent
سؤال
The term separately derived system as defined in NEC Article 100 means that the transfer equipment must break all system conductors from the generator, including the neutral.
سؤال
If a homeowner has a generator without GFCI protection, a listed ____________________ that has GFCI protection may be used.
سؤال
NEC 590.6(A)(3) requires that all 125 volt and 125/250 volt, single-phase, 15-, 20-, and 30 ampere receptacle outlets that are a part of a ____ kW or smaller portable generator shall have listed groundfault circuit interrupter protection for personnel.

A) 10
B) 15
C) 25
D) 50
سؤال
Which loads in a house are homeowners typically concerned about continuing to have power in the event of a power outage?
سؤال
The generator for a standby power system is permanently installed on a concrete pad at a suitable location outside of the home.
سؤال
Generators for home use are generally rated in ____________________.
سؤال
A transfer switch shifts power from the normal utility source to the ____________________.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 32: Standby Power Systems
1
Where the normal power main service disconnecting means is located inside of the home, some electrical inspectors will require that a disconnect for the standby power from the generator be installed near the back door of the home.
False
2
Because generators produce a certain level of ____________________ when running, you will want to check with your building authorities to make sure the generator you choose is in compliance with local codes that might be applicable.
noise
decibels
3
For home installations, transfer switches may be ____________________ or double-pole, double throw (DPDT), depending on how the type of system is being installed.
3-pole double throw
TPDT
3-pole double throw (TPDT)
4
How must a transfer switch connected to the line side of the main service disconnect be listed?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
Standby power conductors and normal power conductors must not be run in the same raceway or enclosure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
Actual wiring of a typical standby generator consists of ____ ungrounded conductor(s) and one grounded "neutral" conductor.

A) one
B) two
C) three
D) four
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
What must a transfer switch must do in such a way that there is no feedback from the generator to the utility system?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
The conductors that run from the standby generator to the transfer switch and to the generator panelboard that contains the branch-circuit overcurrent devices shall be sized not less than ____ percent of the generator's nameplate current rating.

A) 80 percent
B) 115 percent
C) 125 percent
D) 150 percent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
The term separately derived system as defined in NEC Article 100 means that the transfer equipment must break all system conductors from the generator, including the neutral.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
If a homeowner has a generator without GFCI protection, a listed ____________________ that has GFCI protection may be used.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
NEC 590.6(A)(3) requires that all 125 volt and 125/250 volt, single-phase, 15-, 20-, and 30 ampere receptacle outlets that are a part of a ____ kW or smaller portable generator shall have listed groundfault circuit interrupter protection for personnel.

A) 10
B) 15
C) 25
D) 50
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
Which loads in a house are homeowners typically concerned about continuing to have power in the event of a power outage?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
The generator for a standby power system is permanently installed on a concrete pad at a suitable location outside of the home.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
Generators for home use are generally rated in ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
A transfer switch shifts power from the normal utility source to the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.