Deck 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a

ملء الشاشة (f)
exit full mode
سؤال
To determine the minimum amount of CFM needed, multiply the square footage of the house by four.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The NEC requires GFCI protection for ____.

A) hydromassage tubs and all their associated electrical components
B) all receptacles located within 15 ft of the inside wall of a hydromassage tub
C) lighting fixtures located within 5 ft of the inside wall of a hydromassage tub
D) both a and b
سؤال
Never connect the green equipment grounding conductor to the ____________________ branch circuit conductor.
سؤال
Calculate the current rating of a 1,500-watt heat/vent/light unit for a residential bathroom connected to a 120-volt circuit (ignoring power factor).
سؤال
What is a humidistat?
سؤال
Bathroom exhaust fans, vents for clothes dryers, and similar high-humidity sources are never to be vented directly into the ____________________ or other dead spaces.
سؤال
The NEC considers fixed electric space heating to be a continuous load and the rating of the overcurrent device must not be less than 125 percent of the continuous load. What is the rating of the branch circuit for a 1500-watt space heater on a 120-volt circuit?
سؤال
NEC 300.3(B) states that all conductors of the same circuit and, where used, the neutral and all equipment grounding conductors shall be contained within the same ____.

A) raceway
B) cable tray
C) trench, cable, or cord
D) all of the above
سؤال
Whole house vinyl wraps (____) stop airflow through wall cavities, as well as holding out wind-driven rain from getting behind wood, vinyl, brick, and stucco siding.

A) Vinyk
B) Vinawrap
C) Tywrap
D) Tyvek
سؤال
A hydromassage tub is a(n) ____________________ bathtub equipped with a recirculating piping system, pump and associated equipment.
سؤال
Overload protection prevents an exhaust fan motor from burning out if it ____ for any reason.

A) stalls
B) overheats
C) runs too fast
D) both a and b
سؤال
Exhaust fans mounted into end gables or roofs of residences are available with an adjustable temperature control on the ____ of the fan.

A) base
B) frame
C) inside
D) none of the above
سؤال
The NEC allows which of the following disconnecting means for fixed appliances not over 300 volt-amperes or 1/8 horsepower?

A) branch-circuit breaker
B) attachment plug cap
C) separate disconnect switch
D) all of the above
سؤال
NEC 424.3(B) considers fixed electric space heating to be a continuous load.
سؤال
For what purpose are pilot-light switches commonly used?
سؤال
The heat/vent/light is controlled by four switches, one switch each for the heater, the light, the exhaust fan, and the ____________________.
سؤال
Exhaust fan ventilating capability is rated in ____.

A) AMD
B) CFM
C) MRP
D) CMA
سؤال
According, to NEC 250.142(B), NEVER ground an appliance to the ____ grounded circuit conductor.

A) red
B) white
C) blue
D) green
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/18
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 22: Special-Purpose Outlets for the Bathroom Ceiling Heatventlights K J, the Attic Fan L, and the Hydromassage Tub a
1
To determine the minimum amount of CFM needed, multiply the square footage of the house by four.
False
2
The NEC requires GFCI protection for ____.

A) hydromassage tubs and all their associated electrical components
B) all receptacles located within 15 ft of the inside wall of a hydromassage tub
C) lighting fixtures located within 5 ft of the inside wall of a hydromassage tub
D) both a and b
A
3
Never connect the green equipment grounding conductor to the ____________________ branch circuit conductor.
grounded
white
4
Calculate the current rating of a 1,500-watt heat/vent/light unit for a residential bathroom connected to a 120-volt circuit (ignoring power factor).
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is a humidistat?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
6
Bathroom exhaust fans, vents for clothes dryers, and similar high-humidity sources are never to be vented directly into the ____________________ or other dead spaces.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
7
The NEC considers fixed electric space heating to be a continuous load and the rating of the overcurrent device must not be less than 125 percent of the continuous load. What is the rating of the branch circuit for a 1500-watt space heater on a 120-volt circuit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
8
NEC 300.3(B) states that all conductors of the same circuit and, where used, the neutral and all equipment grounding conductors shall be contained within the same ____.

A) raceway
B) cable tray
C) trench, cable, or cord
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
9
Whole house vinyl wraps (____) stop airflow through wall cavities, as well as holding out wind-driven rain from getting behind wood, vinyl, brick, and stucco siding.

A) Vinyk
B) Vinawrap
C) Tywrap
D) Tyvek
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
10
A hydromassage tub is a(n) ____________________ bathtub equipped with a recirculating piping system, pump and associated equipment.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
11
Overload protection prevents an exhaust fan motor from burning out if it ____ for any reason.

A) stalls
B) overheats
C) runs too fast
D) both a and b
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
12
Exhaust fans mounted into end gables or roofs of residences are available with an adjustable temperature control on the ____ of the fan.

A) base
B) frame
C) inside
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
13
The NEC allows which of the following disconnecting means for fixed appliances not over 300 volt-amperes or 1/8 horsepower?

A) branch-circuit breaker
B) attachment plug cap
C) separate disconnect switch
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
14
NEC 424.3(B) considers fixed electric space heating to be a continuous load.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
15
For what purpose are pilot-light switches commonly used?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
16
The heat/vent/light is controlled by four switches, one switch each for the heater, the light, the exhaust fan, and the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
17
Exhaust fan ventilating capability is rated in ____.

A) AMD
B) CFM
C) MRP
D) CMA
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
18
According, to NEC 250.142(B), NEVER ground an appliance to the ____ grounded circuit conductor.

A) red
B) white
C) blue
D) green
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 18 في هذه المجموعة.