Deck 13: Lighting Branch Circuit for the Living Room

ملء الشاشة (f)
exit full mode
سؤال
For track lighting installed in homes, it is not necessary to add ____________________ for the purpose of branch circuit, feeder, or service-entrance calculations.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Lighting track in residential installations must not be installed ____.

A) in damp or wet locations
B) concealed
C) through walls or partitions
D) all of the above
سؤال
In addition to being fastened to the outlet box, the track for track lighting is generally fastened to the ceiling with ____.

A) toggle bolts
B) screws
C) nails
D) both a and b
سؤال
Electronic dimmers for use only to control incandescent lamps are marked with a(n) ____________________ rating.
سؤال
A receptacle below a 4-way switch in the corner of a living room is required because the Code requires that a receptacle be installed in any wall space ____ in. or more in width.

A) 12
B) 24
C) 36
D) 72
سؤال
Lighting track shall be supported twice if the track is not more than ____________________ ft and shall have one additional support for each additional ____________________ ft track.
سؤال
The most common type of dimmer used in residential applications is rated ____ watts, 125 VAC, 60 hertz.

A) 100
B) 250
C) 600
D) 800
سؤال
What are the two basic types of dimmers?
سؤال
Electronic dimmers use triacs to chop the ac sine wave, so some incandescent lamps might ____ because the lamp filament vibrates.

A) buzz
B) hum
C) pulsate
D) whine
سؤال
Lighting track is not permitted to be installed less than ____ above a finished floor unless it is protected against physical damage, or if the track is of the low-voltage type operating at less than 30 volts rms open-circuit voltage.

A) 5 feet
B) 6 feet
C) 6 feet 7 inches (two meters)
D) 7.5 feet
سؤال
Portable lighting track must meet which of the following requirements?

A) It shall not be longer than 8 feet.
B) It shall have have a cord not less than 5 feet permanently attached to the track.
C) It shall have overcurrent protection (fuse or circuit breaker) built into the plug cap.
D) All of the above
سؤال
The Code section that prohibits running track lighting through walls or partitions is NEC ____________________.
سؤال
Lighting track ____ permitted to be installed within a zone extending 3 feet horizontally and 8 feet vertically from the top of a bathtub rim.

A) is
B) is not
سؤال
Describe two features of electronic dimmers.
سؤال
Lighting track in residential installations shall not be cut to length in the field unless permitted by the ____.

A) builder
B) local building codes
C) homeowner
D) manufacturer
سؤال
Two popular types of electronic dimmers are ____.

A) slide and rotate
B) slide and push
C) push and cord
D) rotate and cord
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/16
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 13: Lighting Branch Circuit for the Living Room
1
For track lighting installed in homes, it is not necessary to add ____________________ for the purpose of branch circuit, feeder, or service-entrance calculations.
additional loads
2
Lighting track in residential installations must not be installed ____.

A) in damp or wet locations
B) concealed
C) through walls or partitions
D) all of the above
D
3
In addition to being fastened to the outlet box, the track for track lighting is generally fastened to the ceiling with ____.

A) toggle bolts
B) screws
C) nails
D) both a and b
D
4
Electronic dimmers for use only to control incandescent lamps are marked with a(n) ____________________ rating.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
5
A receptacle below a 4-way switch in the corner of a living room is required because the Code requires that a receptacle be installed in any wall space ____ in. or more in width.

A) 12
B) 24
C) 36
D) 72
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
6
Lighting track shall be supported twice if the track is not more than ____________________ ft and shall have one additional support for each additional ____________________ ft track.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
7
The most common type of dimmer used in residential applications is rated ____ watts, 125 VAC, 60 hertz.

A) 100
B) 250
C) 600
D) 800
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
8
What are the two basic types of dimmers?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
9
Electronic dimmers use triacs to chop the ac sine wave, so some incandescent lamps might ____ because the lamp filament vibrates.

A) buzz
B) hum
C) pulsate
D) whine
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
10
Lighting track is not permitted to be installed less than ____ above a finished floor unless it is protected against physical damage, or if the track is of the low-voltage type operating at less than 30 volts rms open-circuit voltage.

A) 5 feet
B) 6 feet
C) 6 feet 7 inches (two meters)
D) 7.5 feet
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
11
Portable lighting track must meet which of the following requirements?

A) It shall not be longer than 8 feet.
B) It shall have have a cord not less than 5 feet permanently attached to the track.
C) It shall have overcurrent protection (fuse or circuit breaker) built into the plug cap.
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
12
The Code section that prohibits running track lighting through walls or partitions is NEC ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
13
Lighting track ____ permitted to be installed within a zone extending 3 feet horizontally and 8 feet vertically from the top of a bathtub rim.

A) is
B) is not
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
14
Describe two features of electronic dimmers.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
15
Lighting track in residential installations shall not be cut to length in the field unless permitted by the ____.

A) builder
B) local building codes
C) homeowner
D) manufacturer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
16
Two popular types of electronic dimmers are ____.

A) slide and rotate
B) slide and push
C) push and cord
D) rotate and cord
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 16 في هذه المجموعة.