Deck 9: Lighting Branch Circuit for the Master Bedroom
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/20
العب
ملء الشاشة (f)
Deck 9: Lighting Branch Circuit for the Master Bedroom
1
Briefly define what is meant by "gangable" boxes.
Gangable boxes can be combined to form larger boxes by removing their side walls and screwing them together.
2
When installing a ceiling paddle fan, the outlet box must be ____.
A) listed and marked as acceptable for fan support
B) metallic
C) secured by four screws
D) all of the above
A) listed and marked as acceptable for fan support
B) metallic
C) secured by four screws
D) all of the above
A
3
The outlet box or outlet box system of a ceiling-suspended fans must not support more than ____ pounds must.
A) 25
B) 35
C) 50
D) 70
A) 25
B) 35
C) 50
D) 70
D
4
The suggested fan size for rooms up to 144 square feet is ____________________ inches, and the suggested fan size for rooms up to 500 square feet is ____________________ inches.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
5
A light dimmer ____ be used as a speed control for a ceiling fan or other motor.
A) should
B) should not
A) should
B) should not
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
6
Sliding glass panels ____ considered to be wall space, the same as any other interior or exterior door.
A) are
B) are not
A) are
B) are not
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
7
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Sliding glass panel
a.Receptacles required
b.Receptacles not required
Sliding glass panel
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
8
When replacing an existing luminaire (fixture) with a ceiling-suspended paddle fan, make sure that the existing outlet box is listed and marked as ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
9
Because a homeowner may later decide to install a ceiling fan at any ceiling outlet box serving a lighting fixture, what precaution or provision for the future do many electricians take during original construction?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
10
During the winter, it is suggested that a paddle fan should ____.
A) push air down
B) draw air up
C) not be used
D) only be used on low
A) push air down
B) draw air up
C) not be used
D) only be used on low
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
11
A raised plaster cover (often called a plaster ring or mud ring) is permitted to increase the maximum number of conductors permitted in an outlet box when it is ____.
A) listed as a box extension
B) by the same manufacturer as the box
C) marked with its cubic-inch volume
D) metallic and capable of being grounded
A) listed as a box extension
B) by the same manufacturer as the box
C) marked with its cubic-inch volume
D) metallic and capable of being grounded
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
12
The selection of outlet boxes and switch boxes is made by the electrician. These decisions are based on Code requirements, space allowances, good wiring practices, and ____.
A) homeowner's preferences
B) common sense
C) city building codes
D) cost
A) homeowner's preferences
B) common sense
C) city building codes
D) cost
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
13
How can you tell whether a metallic or nonmetallic outlet box is suitable for safely supporting a ceiling fan?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
14
Ceiling fan speed can be controlled by ____.
A) pull chain on the fan
B) speed control mounted in a wall box
C) remote control similar to TV/VCR type
D) any of the above
A) pull chain on the fan
B) speed control mounted in a wall box
C) remote control similar to TV/VCR type
D) any of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
15
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Fixed room divider
a.Receptacles required
b.Receptacles not required
Fixed room divider
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
16
Some ceiling fan/light units have one lamp socket, whereas others have ____ lamp sockets.
A) four or five
B) six
C) seven
D) eight to ten
A) four or five
B) six
C) seven
D) eight to ten
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
17
Some types of panels and similar building elements are considered wall space when figuring receptacle spacing, and others are not. Match the following.
a.Receptacles required
b.Receptacles not required
Fixed glass panel
a.Receptacles required
b.Receptacles not required
Fixed glass panel
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
18
Receptacle outlets must be installed in any wall space ____ or more in width.
A) 12 in. (300 mm)
B) 18 in. (450 mm)
C) 24 in. (600 mm)
D) 36 in. (900 mm)
A) 12 in. (300 mm)
B) 18 in. (450 mm)
C) 24 in. (600 mm)
D) 36 in. (900 mm)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
19
Which of the following is NOT a reason that ceiling fans must be specially supported?
A) Weight
B) Torque (twisting motion, particularly when first starting)
C) Safe grounding
D) Vibration
A) Weight
B) Torque (twisting motion, particularly when first starting)
C) Safe grounding
D) Vibration
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
20
Fan speed controllers have internal circuitry that is engineered specifically for use on inductive circuits. Do not use a standard ____________________ to control fan motors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck

