1
Using E-speed film (instead of D-speed film)reduces the radiation exposure to the patient by approximately:
A)25%.
B)50%.
C)75%.
D)nearly 100%.
A)25%.
B)50%.
C)75%.
D)nearly 100%.
50%.
2
Scatter radiation is a form of:
A)useful beam.
B)primary radiation.
C)secondary radiation.
D)None are correct
A)useful beam.
B)primary radiation.
C)secondary radiation.
D)None are correct
useful beam.
3
When using rectangular collimation with the paralleling technique,one must use a (an):
A)bite tab.
B)8-inch FFD.
C)bisecting device.
D)localizing film-holding device.
A)bite tab.
B)8-inch FFD.
C)bisecting device.
D)localizing film-holding device.
localizing film-holding device.
4
To get the diagnostic benefits from radiographs,optimum film viewing requirements include all of the following EXCEPT one.Which one is the EXCEPTION?
A)A darkened room
B)Use of a film mount
C)Lamp on dental unit
D)Use of an illuminating device
A)A darkened room
B)Use of a film mount
C)Lamp on dental unit
D)Use of an illuminating device
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
5
All of the following are recommended selection criteria for radiographic exposure EXCEPT one,which one is the EXCEPTION?
A)Dental history
B)Medical history
C)Caries risk assessment
D)Nutritional assessment
E)Thorough clinical examination
A)Dental history
B)Medical history
C)Caries risk assessment
D)Nutritional assessment
E)Thorough clinical examination
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
6
Open-ended,lead-lined (shielded)rectangles or cylinders,and closed-end,pointed cones are the only types of position-indicating devices (PIDs)that should be used.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
7
Film speed and focal-film distance (FFD)determine the contribution of mAs to the patient's radiation exposure.However,the choice of kV affects the contrast of the film and radiation dose.
A)Both statements are true.
B)Both statements are false.
C)First statement is true,second is false.
D)First statement is false,second is true.
A)Both statements are true.
B)Both statements are false.
C)First statement is true,second is false.
D)First statement is false,second is true.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
8
Identify the radiographic technique that provides less radiation exposure to the thyroid gland and eyes:
A)occlusal technique.
B)bite block technique.
C)paralleling technique.
D)bisecting angle technique.
A)occlusal technique.
B)bite block technique.
C)paralleling technique.
D)bisecting angle technique.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
9
The removal of the long wavelength,low energy x-ray photons from the beam is the job of the:
A)filters.
B)collimator.
C)insulating oil.
D)open-ended cone.
A)filters.
B)collimator.
C)insulating oil.
D)open-ended cone.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
10
All of the following can be produced by tube-head drift EXCEPT one.Which one is the EXCEPTION?
A)Blurred image
B)Cone-cut image
C)Darkened image
D)Distorted image
A)Blurred image
B)Cone-cut image
C)Darkened image
D)Distorted image
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
11
What does ALARA stand for?
A)As low as reasonably assessed
B)As little as reasonably affected
C)As long as reasonably achieved
D)As low as reasonably achievable
A)As low as reasonably assessed
B)As little as reasonably affected
C)As long as reasonably achieved
D)As low as reasonably achievable
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
12
The use of pointed PIDs is prohibited because their use results in:
A)cone cutting.
B)increased scatter radiation.
C)increased primary radiation.
D)greater likelihood of overlapping images.
A)cone cutting.
B)increased scatter radiation.
C)increased primary radiation.
D)greater likelihood of overlapping images.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of the following results in the greatest reduction of radiation to the patient?
A)Low kVp
B)High mA
C)Short developing time
D)Rectangular collimation
A)Low kVp
B)High mA
C)Short developing time
D)Rectangular collimation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
14
When compared to the use of D-speed film digital imaging can reduce the patient's radiation exposure by up to what percent?
A)25%
B)50%
C)80%
D)90%
A)25%
B)50%
C)80%
D)90%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
15
Why is an increased target-receptor distance (FFDs)of up to 16 inches recommended with the paralleling technique?
A)To decrease patient movement
B)To decrease the patient's skin exposure
C)To reduce the possibility of collimator cutoff
D)To compensate for the magnification of the image
A)To decrease patient movement
B)To decrease the patient's skin exposure
C)To reduce the possibility of collimator cutoff
D)To compensate for the magnification of the image
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
16
The collimator limits the size and shape of the x-ray beam to no more than:
A)inches at the skin.
B)Inches at the skin.
C)inches at the skin.
D)Inches at the skin.
A)inches at the skin.
B)Inches at the skin.
C)inches at the skin.
D)Inches at the skin.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
17
Tube-head leakage is the radiation that escapes through the protective shielding of the x-ray tube head.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
18
The primary radiation is collimated by the aluminum filters.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
19
Administrative radiographs are taken to confirm that procedures have been completed.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
20
Mechanical timers are usually inaccurate by at least a quarter second.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck