Deck 7: Radiographic Imaging

ملء الشاشة (f)
exit full mode
سؤال
All of the following are related except

A) source of electrons.
B) means for setting electrons in high-speed motion.
C) a target to stop or suddenly decelerate the electron travel.
D) aluminum filtration material.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Bowel gas in the abdomen is an example of a _____ material,with regard to the X-ray beam.

A) radiopaque
B) radiolucent
C) radiofrequent
D) radioresistant
سؤال
As you position patients for various radiographic procedures,you will occasionally angle the X-ray tube assembly.This intentional use of tube angles is referred to as

A) size distortion.
B) size minification.
C) shape distortion.
D) magnification.
سؤال
The invisible,unprocessed data on an image detector immediately after X-ray exposure forms the _____ image.

A) remnant
B) manifest
C) primary
D) latent
سؤال
A direct capture digital radiography detector uses _____ as the receptor material.

A) silver bromide
B) amorphous silicon
C) amorphous selenium
D) barium fluorohalide
سؤال
The x-radiation that is "left over" and exits the patient to strike the image receptor and create the image is known as _____ radiation.

A) remnant
B) primary
C) scatter and secondary
D) nuclear
سؤال
When radiographic images of patients are created,many exposure variables come into play to produce optimum image quality.Any change in the radiographic image appearance should be the result of

A) the experience and competency of the technologist.
B) the radiation output of the X-ray machine.
C) the patient's medical condition as reflected in the image characteristics.
D) computer processing to enhance image contrast.
سؤال
The component that intercepts the remnant radiation from a patient and creates the radiographic image is the

A) radiographic grid.
B) collimator.
C) image receptor.
D) table top.
سؤال
As you process a radiographic image of the abdomen of a small child,you notice a small ring-like object on the image.It appears this object is in the patient's stomach,which is consistent with the examination history.The ring shows on the X-ray image because of its metallic density.This is the result of

A) attenuation of the X-ray beam by the metallic density of the ring.
B) transmission of the X-ray beam through the soft metal of the ring.
C) electrons from the X-ray tube striking the patient.
D) scatter radiation from the patient.
سؤال
Sub-optimum mAs exposures in CR imaging technology will yield an image that is

A) grainy and demonstrates quantum mottle.
B) magnified and distorted.
C) minified and distorted.
D) overexposed and too dark to interpret.
سؤال
X-ray film imaging has been replaced by

A) computed radiography (CR).
B) direct and indirect digital detector technology.
C) digital radiography (DR)systems.
D) All of the above
سؤال
As you perform a portable chest radiograph,the optimal SID of 40 inches is unattainable because of orthopedic supports over the patient.It is necessary for you to shorten the SID to 34 inches.A professional radiographer should do which of the following?

A) Indicate the shorter SID on the examination notes to the radiologist.
B) Prop the patient up to increase the distance 6 inches from the image receptor.
C) Angle the tube cephalad to compensate for the shorter SID.
D) Use a shorter exposure time to improve resolution.
سؤال
Optimum radiographic image quality is a function of proper exposure technique selection.Given the three sets of mAs calculations that follow,all three should yield the same degree of radiographic exposure to a detector.
Exposure 1: 200 mA ×\times 0.05 ms
Exposure 2: 100 mA ×\times 0.10 ms
Exposure 3: 400 mA ×\times 0.025 ms
This is known as

A) the inverse square law.
B) the kVp/mAs ratio.
C) mA/mAs proportionality.
D) mAs reciprocity.
سؤال
The resolution of an image using thin-film-transistor (TFT)technology is determined by the

A) size of the energy traps.
B) storage phosphor plate dimension.
C) detector pixel size.
D) the scanning frequency of the reader optics.
سؤال
The production of x-radiation that occurs in an X-ray tube requires the movement of negatively charged particles traveling from one side of the tube to the other.This movement of charges must occur in

A) an aqueous medium.
B) a vacuum.
C) a tungsten gas environment.
D) the subnuclear space.
سؤال
There are four primary image quality factors.They are

A) SID,mAs,SOD,and kVp.
B) primary radiation,scatter radiation,secondary radiation,and remnant radiation.
C) contrast,IR exposure or density,distortion,and recorded detail.
D) grids,collimation,filtration,and beam restriction.
سؤال
The total quantity of X-ray photons produced during an exposure is determined by the

A) kVp.
B) SID.
C) milliamperage (mA).
D) mAs.
سؤال
Of all of the energy traveling through the X-ray tube during a radiographic exposure,the largest percentage of this electrical energy is converted to

A) x-radiation.
B) infrared energy.
C) thermal energy (heat).
D) mechanical energy.
سؤال
All of the following are true of computed radiography (CR)except

A) it uses cassettes.
B) the image is recorded on an amorphous silicon imaging plate.
C) the active material in CR plates is barium fluorohalide.
D) the image plates are reusable.
سؤال
The X-ray tube component that stops the stream of electrons and produces the X-ray beam is called the

A) cathode.
B) anode.
C) tetrode.
D) positode.
سؤال
The dynamic display of a patient's anatomy using x-radiation is termed

A) fluoroscopy.
B) tomosynthesis.
C) image intensification.
D) real-time radiography.
سؤال
The loss of radiographic image resolution is often referred to as unsharpness.All of the following contribute to total image unsharpness except the

A) size and shape of the patient's anatomy.
B) pixel size of the image receptor (IR)and monitor display.
C) size and shape of the exposure field (collimation).
D) image geometry factors such as SID,OID,and focal spot size.
سؤال
An effective measure of actual exposure compared to a target exposure value is the use of a(n)

A) S number.
B) deviation index (DI).
C) exposure index (EI).
D) half-value layer.
سؤال
A very effective method for reducing your exposure to radiation during an exposure is to take advantage of distance.You can reduce your exposure by a factor of nine if you

A) double your distance.
B) triple your distance.
C) increase your distance according to the 15% rule.
D) increase your distance directly by a factor of nine.
سؤال
Computers and their software programs are essential to the processing of digital image data for digital X-ray images.This software can compensate for wide variances in radiation exposure to produce an image.Sub-optimum or excessive exposure is compensated for through a process referred to as

A) automatic rescaling.
B) automatic processing.
C) the 15% rule.
D) pixel value optimization.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 7: Radiographic Imaging
1
All of the following are related except

A) source of electrons.
B) means for setting electrons in high-speed motion.
C) a target to stop or suddenly decelerate the electron travel.
D) aluminum filtration material.
D
2
Bowel gas in the abdomen is an example of a _____ material,with regard to the X-ray beam.

A) radiopaque
B) radiolucent
C) radiofrequent
D) radioresistant
B
3
As you position patients for various radiographic procedures,you will occasionally angle the X-ray tube assembly.This intentional use of tube angles is referred to as

A) size distortion.
B) size minification.
C) shape distortion.
D) magnification.
C
4
The invisible,unprocessed data on an image detector immediately after X-ray exposure forms the _____ image.

A) remnant
B) manifest
C) primary
D) latent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
A direct capture digital radiography detector uses _____ as the receptor material.

A) silver bromide
B) amorphous silicon
C) amorphous selenium
D) barium fluorohalide
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
The x-radiation that is "left over" and exits the patient to strike the image receptor and create the image is known as _____ radiation.

A) remnant
B) primary
C) scatter and secondary
D) nuclear
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
When radiographic images of patients are created,many exposure variables come into play to produce optimum image quality.Any change in the radiographic image appearance should be the result of

A) the experience and competency of the technologist.
B) the radiation output of the X-ray machine.
C) the patient's medical condition as reflected in the image characteristics.
D) computer processing to enhance image contrast.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
The component that intercepts the remnant radiation from a patient and creates the radiographic image is the

A) radiographic grid.
B) collimator.
C) image receptor.
D) table top.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
As you process a radiographic image of the abdomen of a small child,you notice a small ring-like object on the image.It appears this object is in the patient's stomach,which is consistent with the examination history.The ring shows on the X-ray image because of its metallic density.This is the result of

A) attenuation of the X-ray beam by the metallic density of the ring.
B) transmission of the X-ray beam through the soft metal of the ring.
C) electrons from the X-ray tube striking the patient.
D) scatter radiation from the patient.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
Sub-optimum mAs exposures in CR imaging technology will yield an image that is

A) grainy and demonstrates quantum mottle.
B) magnified and distorted.
C) minified and distorted.
D) overexposed and too dark to interpret.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
X-ray film imaging has been replaced by

A) computed radiography (CR).
B) direct and indirect digital detector technology.
C) digital radiography (DR)systems.
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
As you perform a portable chest radiograph,the optimal SID of 40 inches is unattainable because of orthopedic supports over the patient.It is necessary for you to shorten the SID to 34 inches.A professional radiographer should do which of the following?

A) Indicate the shorter SID on the examination notes to the radiologist.
B) Prop the patient up to increase the distance 6 inches from the image receptor.
C) Angle the tube cephalad to compensate for the shorter SID.
D) Use a shorter exposure time to improve resolution.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
Optimum radiographic image quality is a function of proper exposure technique selection.Given the three sets of mAs calculations that follow,all three should yield the same degree of radiographic exposure to a detector.
Exposure 1: 200 mA ×\times 0.05 ms
Exposure 2: 100 mA ×\times 0.10 ms
Exposure 3: 400 mA ×\times 0.025 ms
This is known as

A) the inverse square law.
B) the kVp/mAs ratio.
C) mA/mAs proportionality.
D) mAs reciprocity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
The resolution of an image using thin-film-transistor (TFT)technology is determined by the

A) size of the energy traps.
B) storage phosphor plate dimension.
C) detector pixel size.
D) the scanning frequency of the reader optics.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
The production of x-radiation that occurs in an X-ray tube requires the movement of negatively charged particles traveling from one side of the tube to the other.This movement of charges must occur in

A) an aqueous medium.
B) a vacuum.
C) a tungsten gas environment.
D) the subnuclear space.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
There are four primary image quality factors.They are

A) SID,mAs,SOD,and kVp.
B) primary radiation,scatter radiation,secondary radiation,and remnant radiation.
C) contrast,IR exposure or density,distortion,and recorded detail.
D) grids,collimation,filtration,and beam restriction.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
The total quantity of X-ray photons produced during an exposure is determined by the

A) kVp.
B) SID.
C) milliamperage (mA).
D) mAs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
Of all of the energy traveling through the X-ray tube during a radiographic exposure,the largest percentage of this electrical energy is converted to

A) x-radiation.
B) infrared energy.
C) thermal energy (heat).
D) mechanical energy.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
All of the following are true of computed radiography (CR)except

A) it uses cassettes.
B) the image is recorded on an amorphous silicon imaging plate.
C) the active material in CR plates is barium fluorohalide.
D) the image plates are reusable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
The X-ray tube component that stops the stream of electrons and produces the X-ray beam is called the

A) cathode.
B) anode.
C) tetrode.
D) positode.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
The dynamic display of a patient's anatomy using x-radiation is termed

A) fluoroscopy.
B) tomosynthesis.
C) image intensification.
D) real-time radiography.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
The loss of radiographic image resolution is often referred to as unsharpness.All of the following contribute to total image unsharpness except the

A) size and shape of the patient's anatomy.
B) pixel size of the image receptor (IR)and monitor display.
C) size and shape of the exposure field (collimation).
D) image geometry factors such as SID,OID,and focal spot size.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
An effective measure of actual exposure compared to a target exposure value is the use of a(n)

A) S number.
B) deviation index (DI).
C) exposure index (EI).
D) half-value layer.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
A very effective method for reducing your exposure to radiation during an exposure is to take advantage of distance.You can reduce your exposure by a factor of nine if you

A) double your distance.
B) triple your distance.
C) increase your distance according to the 15% rule.
D) increase your distance directly by a factor of nine.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
Computers and their software programs are essential to the processing of digital image data for digital X-ray images.This software can compensate for wide variances in radiation exposure to produce an image.Sub-optimum or excessive exposure is compensated for through a process referred to as

A) automatic rescaling.
B) automatic processing.
C) the 15% rule.
D) pixel value optimization.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.