Deck 3: The Electrocardiograph

ملء الشاشة (f)
exit full mode
سؤال
Signal processing, which occurs inside the ECG machine,

A)amplifies the electrical impulse.
B)directs impulses to the ECG instrument.
C)notifies the operator of input errors.
D)provides an initial interpretation of the tracing.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
You are preparing to conduct a 12-lead ECG on a patient. As you are gathering your supplies, you notice that five of the electrodes are made by one company and the other five electrodes are made by another company. What is your next step?

A)Conduct the 12-lead ECG with the electrodes present.
B)Find a complete set of 10 electrodes that are the same.
C)Tell your immediate supervisor that you couldn't conduct the 12-lead ECG procedure.
D)Tell the patient to come back at another time when you have all the equipment.
سؤال
You are performing a 12-lead ECG on a hospital patient using a portable ECG machine on a cart. As you are conducting the ECG, a red line appears at the bottom of the ECG graph paper. What should you do?

A)Stop the ECG and check the placement of the electrodes.
B)Continue the ECG, but remember to replace the paper before performing the next ECG.
C)Stop the ECG and replace the paper, then resume conducting the ECG.
D)Continue the ECG, but make a note on the ECG tracing that the patient moved during the recording.
سؤال
The Einthoven triangle is formed by the following three limb leads:

A)right arm, left arm, right leg.
B)right leg, left arm, left leg.
C)right arm, left arm, left leg.
D)right leg, left leg, right arm.
سؤال
To obtain a 12-lead ECG tracing, you must apply how many lead wires and electrodes to the patient?

A)8
B)12
C)10
D)3
سؤال
The gain control is normally set at:

A)10 mm/mV.
B)20 mm/mV.
C)5 mm/mV.
D)25 mm/mV.
سؤال
The V2 lead should be placed at the:

A)fourth intercostal space, left sternal border.
B)fifth intercostal space at the midclavicular line.
C)fifth intercostal space, midaxillary line.
D)fourth intercostal space, right sternal border.
سؤال
Which of the following is not considered a bipolar lead?

A)Lead I
B)Lead II
C)aVR
D)Lead III
سؤال
Which of the following is not a type of lead used in a 12-lead ECG?

A)Bipolar
B)Unipolar
C)Chest
D)Abdomen
سؤال
Which type of electrode is preferred for use in a hospital or acute care setting?

A)Disposable electrodes
B)Plastic electrodes
C)Silver electrodes
D)Copper electrodes
سؤال
The ECG graph paper represents time horizontally and voltage vertically. What time and voltage are represented by one large box?

A)0)04 second and 0.1 mV
B)0)20 second and 0.5 mV
C)1 second and 0.4 mV
D)0)5 second and 0.2 mV
سؤال
The leads that make up a 12-lead ECG consist of:

A)6 standard, 3 augmented, and 3 chest leads.
B)3 standard, 3 augmented, and 6 chest leads.
C)6 augmented, 3 standard, and 3 chest leads.
D)4 augmented, 4 standard, and 4 chest leads.
سؤال
Unipolar leads include all the lead types except:

A)standard leads.
B)augmented leads.
C)chest leads.
D)precordial leads.
سؤال
The usual setting for the artifact filter is:

A)10 to 20 Hz.
B)20 to 40 Hz.
C)40 to 150 Hz.
D)100 to 250 Hz.
سؤال
For the proper placement of V3, you must have placed which other two leads on the patient's chest?

A)V2 and V4
B)V2 and V5
C)V5 and V4
D)V4 and V6
سؤال
The V1 lead should be placed at the:

A)fourth intercostal space, left sternal border.
B)fifth intercostal space at the midclavicular line.
C)fifth intercostal space, midaxillary line.
D)fourth intercostal space, right sternal border.
سؤال
Which of the following is not a basic function of the electrocardiograph?

A)Input
B)Signal processing
C)Output display
D)Analysis
سؤال
The most commonly used paper speed on the ECG machine is:

A)40 mm/sec.
B)25 mm/sec.
C)10 mm/sec.
D)50 mm/sec.
سؤال
Often it is difficult to read the ECG tracing if a patient's heart rate is fast. Where should you set the speed control to be able to interpret the ECG tracing more easily?

A)15 mm/sec
B)25 mm/sec
C)50 mm/sec
D)100 mm/sec
سؤال
The ECG waveform is indicative of:

A)how the heart is functioning electrically.
B)abnormal heart valve conditions.
C)the contraction of heart muscles.
D)the heart's pumping capability.
سؤال
When the paper speed is 25 mm/sec, how many boxes are present in a 1-minute recording?

A)150 boxes per minute
B)600 boxes per minute
C)300 boxes per minute
D)450 boxes per minute
سؤال
Computerized interpretation of the ECG tracing:

A)can be used for the actual diagnosis.
B)is usually validated by the technician.
C)must be validated by a physician.
D)replaces the physician's interpretation.
سؤال
Which one of these is not a commonly used method to calculate heart rates?

A)R-R method
B)1500 method
C)1-minute method
D)6-second method
سؤال
Each little box on the ECG paper horizontally represents:

A)0)04 second.
B)0)20 second.
C)1 mV.
D)1 second.
سؤال
A multichannel ECG monitors all 12 leads but usually records how many leads at one time?

A)12 leads
B)3 leads
C)1 lead
D)4 leads
سؤال
When estimating the heart rate with the 6-second method, you locate 6 seconds on a rhythm strip, count the number of complexes, and multiply by:

A)10.
B)60.
C)5)
D)15.
سؤال
The process of studying a current ECG tracing along with older ECGs taken at intervals to note differences in a patient's condition is:

A)multichannel recording.
B)ECG calibration.
C)serial ECG comparison.
D)quality control inspection.
سؤال
How long must the ECG tracing be maintained as part of a patient's medical record?

A)7 years
B)3 years
C)10 years
D)15 years
سؤال
Which of the following is a valid reason to change the speed of the ECG tracing?

A)The patient is a paramedic and requests a different speed.
B)You cannot clearly identify the waves because they are too close together.
C)The patient is having difficulty breathing.
D)The patient has high blood pressure.
سؤال
Which of the following is an advantage of using dot matrix paper instead of the standard grid paper?

A)Dot matrix paper is a heat-transfer paper that does not require ink.
B)Dot matrix paper is less expensive than standard grid paper.
C)Dot matrix paper produces sharper photocopies than standard grid paper.
D)Dot matrix paper is more readily available than standard grid paper.
سؤال
Which heart rate method is the most accurate with regular rhythms?

A)R-R method
B)6-second method
C)1500 method
D)300 method
سؤال
Which method of calculating the heart rate is shown below? <strong>Which method of calculating the heart rate is shown below?  </strong> A)1500 method B)R-R method C)6-second method D)1-minute method <div style=padding-top: 35px>

A)1500 method
B)R-R method
C)6-second method
D)1-minute method
سؤال
The term tachycardia means:

A)fast heart rate.
B)slow heart rate.
C)normal heart rate.
D)absence of heart rate.
سؤال
Which of the following substances can accidentally erase an ECG tracing?

A)Standard copier paper
B)Pencil lead
C)Plastic
D)Cardboard
سؤال
If you attempt to record an ECG and no tracing appears, what should you do?

A)Recheck the lead wires to make sure they are placed correctly.
B)Notify the physician.
C)Switch the arm and leg leads.
D)Stop the procedure and explain to the patient that the machine is malfunctioning.
سؤال
Using the 1500 method, calculate the heart rate. <strong>Using the 1500 method, calculate the heart rate.  </strong> A)40 bpm B)60 bpm C)80 bpm D)20 bpm <div style=padding-top: 35px>

A)40 bpm
B)60 bpm
C)80 bpm
D)20 bpm
سؤال
How many leads does a multichannel recorder monitor at one time?

A)3
B)6
C)10
D)12
سؤال
To perform an ECG with accuracy, the best source to obtain specific information about the machine you are using is to consult:

A)the policy and procedure manual.
B)the manufacturer's instructions.
C)your supervisor.
D)a co-worker.
سؤال
Which method is the only one to be used for irregular rhythms?

A)R-R method
B)6-second method
C)1500 method
D)1-minute method
سؤال
The term bradycardia means:

A)fast heart rate.
B)slow heart rate.
C)normal heart rate.
D)absence of heart rate.
سؤال
Which of the following has enhanced a patient's right to control his or her own health information, making it necessary to handle ECG tracings confidentially?

A)OSHA
B)HIPAA
C)CDC
D)AHA
سؤال
When serial ECGs are performed on a patient, which of the following guidelines should be followed to ensure accurate results?

A)The patient should not move between ECGs.
B)The patient should not eat or drink between ECGs.
C)The electrode placement must be the same for each ECG.
D)The electrodes must be changed for each successive ECG.
سؤال
Which method of estimating heart rate should you use for this tracing, and what is the estimated heart rate? <strong>Which method of estimating heart rate should you use for this tracing, and what is the estimated heart rate?  </strong> A)R-R method, 50 bpm B)1500 method, 58 bpm C)1500 method, 100 bpm D)6-second method, 70 bpm <div style=padding-top: 35px>

A)R-R method, 50 bpm
B)1500 method, 58 bpm
C)1500 method, 100 bpm
D)6-second method, 70 bpm
سؤال
Unwanted marks on an ECG tracing that are not related to the heart's electrical activity are known as:

A)gain.
B)artifact.
C)input.
D)output.
سؤال
The control on the ECG machine that increases or decreases the size of the ECG tracing is the:

A)speed control.
B)artifact filter.
C)gain control.
D)heart rate limit control.
سؤال
Use the R-R method to estimate the heart rate. <strong>Use the R-R method to estimate the heart rate.  </strong> A)27 bpm B)43 bpm C)58 bpm D)75 bpm <div style=padding-top: 35px>

A)27 bpm
B)43 bpm
C)58 bpm
D)75 bpm
سؤال
Use the 1500 method to estimate the heart rate. <strong>Use the 1500 method to estimate the heart rate.  </strong> A)50 bpm B)75 bpm C)100 bpm D)125 bpm <div style=padding-top: 35px>

A)50 bpm
B)75 bpm
C)100 bpm
D)125 bpm
سؤال
ECG machines are calibrated so that:

A)1 cm = 1 second.
B)1 mV = 1 second.
C)1 cm = 1 mV.
D)1 mV = 0.5 cm.
سؤال
Estimate the heart rate using the 1500 method. <strong>Estimate the heart rate using the 1500 method.  </strong> A)100 bpm B)125 bpm C)150 bpm D)160 bpm <div style=padding-top: 35px>

A)100 bpm
B)125 bpm
C)150 bpm
D)160 bpm
سؤال
Which type of electrode is most commonly used to perform an ECG?

A)Carbon
B)Silver
C)Gold
D)Disposable
سؤال
You are preparing to perform an ECG on a patient. When you open a new package of disposable electrodes, you notice that the gel appears to have dried out on some of the electrodes. What should you do?

A)Use them because they are new and the package was sealed.
B)Apply new gel to the electrodes and use them.
C)Consult your supervisor about whether to use the electrodes.
D)Discard the electrodes and open another package.
سؤال
Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds. <strong>Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds.  </strong> A)80 bpm B)100 bpm C)140 bpm D)160 bpm <div style=padding-top: 35px>

A)80 bpm
B)100 bpm
C)140 bpm
D)160 bpm
سؤال
Which of the following conditions can an ECG machine detect if you set up heart rate limits on the machine?

A)Tachycardia
B)Congestive heart failure
C)Myocardial infarction
D)Ischemia
سؤال
Estimate the heart rate using the R-R method. <strong>Estimate the heart rate using the R-R method.  </strong> A)100 bpm B)125 bpm C)150 bpm D)160 bpm <div style=padding-top: 35px>

A)100 bpm
B)125 bpm
C)150 bpm
D)160 bpm
سؤال
Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds. <strong>Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds.  </strong> A)140 B)84 C)120 D)70 <div style=padding-top: 35px>

A)140
B)84
C)120
D)70
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/55
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 3: The Electrocardiograph
1
Signal processing, which occurs inside the ECG machine,

A)amplifies the electrical impulse.
B)directs impulses to the ECG instrument.
C)notifies the operator of input errors.
D)provides an initial interpretation of the tracing.
amplifies the electrical impulse.
2
You are preparing to conduct a 12-lead ECG on a patient. As you are gathering your supplies, you notice that five of the electrodes are made by one company and the other five electrodes are made by another company. What is your next step?

A)Conduct the 12-lead ECG with the electrodes present.
B)Find a complete set of 10 electrodes that are the same.
C)Tell your immediate supervisor that you couldn't conduct the 12-lead ECG procedure.
D)Tell the patient to come back at another time when you have all the equipment.
Find a complete set of 10 electrodes that are the same.
3
You are performing a 12-lead ECG on a hospital patient using a portable ECG machine on a cart. As you are conducting the ECG, a red line appears at the bottom of the ECG graph paper. What should you do?

A)Stop the ECG and check the placement of the electrodes.
B)Continue the ECG, but remember to replace the paper before performing the next ECG.
C)Stop the ECG and replace the paper, then resume conducting the ECG.
D)Continue the ECG, but make a note on the ECG tracing that the patient moved during the recording.
Continue the ECG, but remember to replace the paper before performing the next ECG.
4
The Einthoven triangle is formed by the following three limb leads:

A)right arm, left arm, right leg.
B)right leg, left arm, left leg.
C)right arm, left arm, left leg.
D)right leg, left leg, right arm.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
5
To obtain a 12-lead ECG tracing, you must apply how many lead wires and electrodes to the patient?

A)8
B)12
C)10
D)3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
6
The gain control is normally set at:

A)10 mm/mV.
B)20 mm/mV.
C)5 mm/mV.
D)25 mm/mV.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
7
The V2 lead should be placed at the:

A)fourth intercostal space, left sternal border.
B)fifth intercostal space at the midclavicular line.
C)fifth intercostal space, midaxillary line.
D)fourth intercostal space, right sternal border.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
8
Which of the following is not considered a bipolar lead?

A)Lead I
B)Lead II
C)aVR
D)Lead III
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
9
Which of the following is not a type of lead used in a 12-lead ECG?

A)Bipolar
B)Unipolar
C)Chest
D)Abdomen
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
10
Which type of electrode is preferred for use in a hospital or acute care setting?

A)Disposable electrodes
B)Plastic electrodes
C)Silver electrodes
D)Copper electrodes
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
11
The ECG graph paper represents time horizontally and voltage vertically. What time and voltage are represented by one large box?

A)0)04 second and 0.1 mV
B)0)20 second and 0.5 mV
C)1 second and 0.4 mV
D)0)5 second and 0.2 mV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
12
The leads that make up a 12-lead ECG consist of:

A)6 standard, 3 augmented, and 3 chest leads.
B)3 standard, 3 augmented, and 6 chest leads.
C)6 augmented, 3 standard, and 3 chest leads.
D)4 augmented, 4 standard, and 4 chest leads.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
13
Unipolar leads include all the lead types except:

A)standard leads.
B)augmented leads.
C)chest leads.
D)precordial leads.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
14
The usual setting for the artifact filter is:

A)10 to 20 Hz.
B)20 to 40 Hz.
C)40 to 150 Hz.
D)100 to 250 Hz.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
15
For the proper placement of V3, you must have placed which other two leads on the patient's chest?

A)V2 and V4
B)V2 and V5
C)V5 and V4
D)V4 and V6
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
16
The V1 lead should be placed at the:

A)fourth intercostal space, left sternal border.
B)fifth intercostal space at the midclavicular line.
C)fifth intercostal space, midaxillary line.
D)fourth intercostal space, right sternal border.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
17
Which of the following is not a basic function of the electrocardiograph?

A)Input
B)Signal processing
C)Output display
D)Analysis
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
18
The most commonly used paper speed on the ECG machine is:

A)40 mm/sec.
B)25 mm/sec.
C)10 mm/sec.
D)50 mm/sec.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
19
Often it is difficult to read the ECG tracing if a patient's heart rate is fast. Where should you set the speed control to be able to interpret the ECG tracing more easily?

A)15 mm/sec
B)25 mm/sec
C)50 mm/sec
D)100 mm/sec
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
20
The ECG waveform is indicative of:

A)how the heart is functioning electrically.
B)abnormal heart valve conditions.
C)the contraction of heart muscles.
D)the heart's pumping capability.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
21
When the paper speed is 25 mm/sec, how many boxes are present in a 1-minute recording?

A)150 boxes per minute
B)600 boxes per minute
C)300 boxes per minute
D)450 boxes per minute
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
22
Computerized interpretation of the ECG tracing:

A)can be used for the actual diagnosis.
B)is usually validated by the technician.
C)must be validated by a physician.
D)replaces the physician's interpretation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
23
Which one of these is not a commonly used method to calculate heart rates?

A)R-R method
B)1500 method
C)1-minute method
D)6-second method
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
24
Each little box on the ECG paper horizontally represents:

A)0)04 second.
B)0)20 second.
C)1 mV.
D)1 second.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
25
A multichannel ECG monitors all 12 leads but usually records how many leads at one time?

A)12 leads
B)3 leads
C)1 lead
D)4 leads
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
26
When estimating the heart rate with the 6-second method, you locate 6 seconds on a rhythm strip, count the number of complexes, and multiply by:

A)10.
B)60.
C)5)
D)15.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
27
The process of studying a current ECG tracing along with older ECGs taken at intervals to note differences in a patient's condition is:

A)multichannel recording.
B)ECG calibration.
C)serial ECG comparison.
D)quality control inspection.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
28
How long must the ECG tracing be maintained as part of a patient's medical record?

A)7 years
B)3 years
C)10 years
D)15 years
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
29
Which of the following is a valid reason to change the speed of the ECG tracing?

A)The patient is a paramedic and requests a different speed.
B)You cannot clearly identify the waves because they are too close together.
C)The patient is having difficulty breathing.
D)The patient has high blood pressure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
30
Which of the following is an advantage of using dot matrix paper instead of the standard grid paper?

A)Dot matrix paper is a heat-transfer paper that does not require ink.
B)Dot matrix paper is less expensive than standard grid paper.
C)Dot matrix paper produces sharper photocopies than standard grid paper.
D)Dot matrix paper is more readily available than standard grid paper.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
31
Which heart rate method is the most accurate with regular rhythms?

A)R-R method
B)6-second method
C)1500 method
D)300 method
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
32
Which method of calculating the heart rate is shown below? <strong>Which method of calculating the heart rate is shown below?  </strong> A)1500 method B)R-R method C)6-second method D)1-minute method

A)1500 method
B)R-R method
C)6-second method
D)1-minute method
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
33
The term tachycardia means:

A)fast heart rate.
B)slow heart rate.
C)normal heart rate.
D)absence of heart rate.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
34
Which of the following substances can accidentally erase an ECG tracing?

A)Standard copier paper
B)Pencil lead
C)Plastic
D)Cardboard
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
35
If you attempt to record an ECG and no tracing appears, what should you do?

A)Recheck the lead wires to make sure they are placed correctly.
B)Notify the physician.
C)Switch the arm and leg leads.
D)Stop the procedure and explain to the patient that the machine is malfunctioning.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
36
Using the 1500 method, calculate the heart rate. <strong>Using the 1500 method, calculate the heart rate.  </strong> A)40 bpm B)60 bpm C)80 bpm D)20 bpm

A)40 bpm
B)60 bpm
C)80 bpm
D)20 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
37
How many leads does a multichannel recorder monitor at one time?

A)3
B)6
C)10
D)12
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
38
To perform an ECG with accuracy, the best source to obtain specific information about the machine you are using is to consult:

A)the policy and procedure manual.
B)the manufacturer's instructions.
C)your supervisor.
D)a co-worker.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
39
Which method is the only one to be used for irregular rhythms?

A)R-R method
B)6-second method
C)1500 method
D)1-minute method
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
40
The term bradycardia means:

A)fast heart rate.
B)slow heart rate.
C)normal heart rate.
D)absence of heart rate.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
41
Which of the following has enhanced a patient's right to control his or her own health information, making it necessary to handle ECG tracings confidentially?

A)OSHA
B)HIPAA
C)CDC
D)AHA
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
42
When serial ECGs are performed on a patient, which of the following guidelines should be followed to ensure accurate results?

A)The patient should not move between ECGs.
B)The patient should not eat or drink between ECGs.
C)The electrode placement must be the same for each ECG.
D)The electrodes must be changed for each successive ECG.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
43
Which method of estimating heart rate should you use for this tracing, and what is the estimated heart rate? <strong>Which method of estimating heart rate should you use for this tracing, and what is the estimated heart rate?  </strong> A)R-R method, 50 bpm B)1500 method, 58 bpm C)1500 method, 100 bpm D)6-second method, 70 bpm

A)R-R method, 50 bpm
B)1500 method, 58 bpm
C)1500 method, 100 bpm
D)6-second method, 70 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
44
Unwanted marks on an ECG tracing that are not related to the heart's electrical activity are known as:

A)gain.
B)artifact.
C)input.
D)output.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
45
The control on the ECG machine that increases or decreases the size of the ECG tracing is the:

A)speed control.
B)artifact filter.
C)gain control.
D)heart rate limit control.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
46
Use the R-R method to estimate the heart rate. <strong>Use the R-R method to estimate the heart rate.  </strong> A)27 bpm B)43 bpm C)58 bpm D)75 bpm

A)27 bpm
B)43 bpm
C)58 bpm
D)75 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
47
Use the 1500 method to estimate the heart rate. <strong>Use the 1500 method to estimate the heart rate.  </strong> A)50 bpm B)75 bpm C)100 bpm D)125 bpm

A)50 bpm
B)75 bpm
C)100 bpm
D)125 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
48
ECG machines are calibrated so that:

A)1 cm = 1 second.
B)1 mV = 1 second.
C)1 cm = 1 mV.
D)1 mV = 0.5 cm.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
49
Estimate the heart rate using the 1500 method. <strong>Estimate the heart rate using the 1500 method.  </strong> A)100 bpm B)125 bpm C)150 bpm D)160 bpm

A)100 bpm
B)125 bpm
C)150 bpm
D)160 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
50
Which type of electrode is most commonly used to perform an ECG?

A)Carbon
B)Silver
C)Gold
D)Disposable
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
51
You are preparing to perform an ECG on a patient. When you open a new package of disposable electrodes, you notice that the gel appears to have dried out on some of the electrodes. What should you do?

A)Use them because they are new and the package was sealed.
B)Apply new gel to the electrodes and use them.
C)Consult your supervisor about whether to use the electrodes.
D)Discard the electrodes and open another package.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
52
Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds. <strong>Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds.  </strong> A)80 bpm B)100 bpm C)140 bpm D)160 bpm

A)80 bpm
B)100 bpm
C)140 bpm
D)160 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
53
Which of the following conditions can an ECG machine detect if you set up heart rate limits on the machine?

A)Tachycardia
B)Congestive heart failure
C)Myocardial infarction
D)Ischemia
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
54
Estimate the heart rate using the R-R method. <strong>Estimate the heart rate using the R-R method.  </strong> A)100 bpm B)125 bpm C)150 bpm D)160 bpm

A)100 bpm
B)125 bpm
C)150 bpm
D)160 bpm
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
55
Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds. <strong>Use the 6-second method to estimate the heart rate. Note: This strip represents exactly six seconds.  </strong> A)140 B)84 C)120 D)70

A)140
B)84
C)120
D)70
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 55 في هذه المجموعة.