Which scanner allows for continuous rotation of the X-ray tube while the patient moves simultaneously through the gantry aperture?

A) Third-generation conventional scanner
B) Fourth-generation conventional scanner
C) Spiral/helical scanner
D) Dynamic volume scanner
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
CT detectors generate a signal that represents the attenuation as the ray moves across the slice. This signal is called:

A) a view sample.
B) an acquisition sample.
C) a profile.
D) a data sample.
سؤال
Which X-ray generator is used in modern CT scanners?

A) Single-phase half-wave rectified
B) Single-phase full-wave rectified
C) High-frequency generator
D) Three-phase, six-pulse generator
سؤال
Compared with conventional CT scanners, slip-ring scanners offer all of the following advantages except:

A) removal of cable wraparound.
B) elimination of start-stop action.
C) capacity for interrupted acquisition protocols.
D) minimal interscan delays.
سؤال
Which CT scanner is based on a fan-beam geometry and complete rotation of the X-ray tube and detectors?

A) First-generation scanner
B) Second-generation scanner
C) Third-generation scanner
D) Fourth-generation scanner
سؤال
A single ray in computed tomography (CT) is:

A) a beam of X-rays emanating from the X-ray tube.
B) a single straight line path of an X-ray beam.
C) the total attenuation as measured by the detector.
D) a collection of beams gathered by the detector.
سؤال
Which generation of scanners, also called dual-source CT scanners, consists of two X-ray tubes and two sets of detectors?

A) Third generation
B) Fourth generation
C) Fifth generation
D) Sixth generation
سؤال
In which scanner is the apex of the fan beam located outside the detector?

A) Third-generation scanner
B) Fourth-generation scanner
C) Fifth-generation scanner
D) Sixth-generation scanner
سؤال
Which of the following is classified as a high-speed CT scanner?

A) Third-generation scanner
B) Fourth-generation scanner
C) Spiral/helical CT scanner
D) Fifth-generation CT scanner
سؤال
Which scanner is based on slip-ring technology?

A) Third-generation conventional scanner
B) Fourth-generation conventional scanner
C) Spiral/helical scanner
D) Fifth-generation scanner
سؤال
The scanner that uses an electron gun to "shoot" electrons toward a target ring is the:

A) fifth-generation scanner.
B) fourth-generation scanner.
C) third-generation scanner.
D) spiral/helical scanner.
سؤال
In one type of fourth-generation CT scanner, the tilting action of the detector ring is referred to as:

A) slip-ring technology.
B) nutating.
C) spiral scanning.
D) helical scanning.
سؤال
Fourth-generation CT scanners are characterized by:

A) rotate-translate motion and parallel beam geometry.
B) rotate-translate motion and fan-beam geometry.
C) fan-beam geometry and continuous rotation of X-ray tube and detectors
D) fan-beam geometry and complete rotation of X-ray tube around a stationary ring of detectors
سؤال
Which of the following X-ray tubes is most likely used in spiral/helical CT scanners?

A) A tungsten target fixed anode tube
B) A tungsten target rotating anode tube
C) A molybdenum target rotating anode tube
D) A rotating anode tube with a rhenium tungsten disk
سؤال
Which of the following refers to the size, shape, motion, and path traced by the X-ray beam as it scans the patient?

A) Beam geometry
B) Projection profile
C) Data acquisition
D) Detector tracing
سؤال
Electromechanical devices made up of rings and brushes to transmit electrical energy across a rotating interface are called:

A) target rings.
B) slip rings.
C) spiral rings.
D) helical rings.
سؤال
A view in CT is:

A) a specific way in which the patient is positioned with respect to the detectors.
B) the total attenuation as measured by the detector.
C) a collection of rays for one translation across the object.
D) a single straight line path of an X-ray beam.
سؤال
The total number of data samples per scan or per slice in CT is the:

A) number of data samples per view times the number of views.
B) number of views.
C) number of detectors plus the number of data samples per detector.
D) number of data samples per view plus the number of views.
سؤال
Which of the following refers to a method by which the patient is systematically scanned by the X-ray tube and detectors to collect enough information for image reconstruction?

A) Beam geometry
B) Data acquisition
C) Sampling
D) Projection reconstruction
سؤال
Which scanner results in a volume of the patient being scanned during a single breath-hold (rather than a single slice of tissue)?

A) Spiral/helical scanner
B) Seventh-generation scanner
C) Second-generation scanner
D) First-generation scanner
سؤال
Which of the following methods does not affect sampling information?

A) Closely packed detectors
B) Milliamperage-seconds (mAs)
C) Slice thickness
D) Double-dynamic focus
سؤال
Which of the following is commonly used in gas-ionization CT detectors?

A) Xenon
B) Oxygen
C) Neon
D) Helium
سؤال
What detector innovation allows for acquisition of both low and high energies for every exposure in CT imaging?

A) Stellar detector
B) Third-generation detector
C) Photon counting detector
D) Dual-layer detector
سؤال
What provides doubling sampling by obtaining two overlapping slices for each detector row per 360-degree rotation?

A) z-flying focal spot technique
B) Double-dynamic focus
C) Quarter-shifted detection
D) Aliasing method
سؤال
The following crystals have been used in scintillation CT detectors except:

A) bismuth germinate.
B) calcium tungstate.
C) calcium fluoride.
D) sodium iodide (NaI).
سؤال
Photodiodes are now used in CT scintillation detectors.
سؤال
Which of the following refers to the ability of the CT detector to capture, absorb, and convert X-ray photons into electrical energy?

A) Efficiency
B) Stability
C) Response time
D) Dynamic range
سؤال
The data acquisition system (DAS) performs each of the following functions except:

A) measures the transmitted radiation beam.
B) encodes these measurements into binary data.
C) powers the rotating components of the gantry.
D) transmits the binary data to the computer.
سؤال
The speed with which a CT detector can detect an X-ray event and recover to detect another event is the:

A) response time.
B) stability.
C) efficiency.
D) dynamic range.
سؤال
The ratio of the largest signal to the smallest signal measured by a CT detector is the:

A) response time.
B) dynamic range.
C) efficiency.
D) stability.
سؤال
The purpose of collimation in CT is each of the following except:

A) create an homogenous beam.
B) to protect the patient.
C) to ensure a constant beam width at the detector.
D) to reduce scatter radiation.
سؤال
The slice thickness in CT is determined by the:

A) focal spot.
B) anode.
C) collimator height.
D) collimator width.
سؤال
All of the following are radiation beams produced by an X-ray tube designed for CT except:

A) homogeneous beam.
B) heterogeneous beam.
C) polychromatic beam.
D) polyenergetic beam.
سؤال
What category of multirow detector array utilizes an isotropic design?

A) Adaptive array detectors
B) Matrix array detectors
C) Unilateral array detectors
D) Identical array detectors
سؤال
Gas-ionization CT detectors convert X-ray photons into electrical signals with no light conversion process in-between.
سؤال
Which detector characteristic refers to the steadiness of the detector response?

A) Efficiency
B) Stability
C) Response time
D) Dynamic range
سؤال
What style of filter is common in CT filtration because it compensates for the difference in beam path length through the axial plane of the object such that a more uniform fluence can be delivered to the detector?

A) Straight filter
B) Bowtie filter
C) Cone filter
D) Star filter
سؤال
What design of collimation is influenced by the size of the focal spot?

A) Prepatient collimation
B) Postpatient collimation
C) Predetector collimation
D) Postdetector collimation
سؤال
The main purpose of a filter used in CT is to:

A) reduce the intensity of the beam at the detector.
B) make the beam less uniform at the detector.
C) decrease the mean energy at the detector.
D) protect the patient.
سؤال
Scintillation detectors convert X-ray photons to light and subsequently to electrical signals.
سؤال
Afterglow refers to the persistence of the image even after the radiation has been turned off.
سؤال
Adaptive section collimation is a design to overcome overscanning, an issue of exposing the patient outside the imaged range which occurs for spiral CT with multirow detectors at the start and the end of the scan.
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Ionization detector

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
سؤال
Multirow CT detectors fall into two categories, namely, matrix array detectors and pixel array detectors.
سؤال
The change of attenuation and thickness data into transmission measurement is called efficiency conversion.
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Scintillation

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
سؤال
Seventh-generation scanners use flat-panel digital area detectors.
سؤال
Contactless slip-ring design uses a conductive wire as its sliding contact.
سؤال
Optoelectronics refers to the use of lens and light diodes to facilitate data transmission.
سؤال
Gas-ionization detectors are prone to afterglow problems.
سؤال
Sixth-generation scanners are referred to as the cine CT scanner because of its high-speed acquisition for imaging the heart and circulation.
سؤال
The configuration of the dual-row detector system results in faster volume coverage compared with single-row CT systems.
سؤال
Streaking artifacts are the result of too many samples being measured by the detectors.
سؤال
Gas-ionization chambers were first introduced in second-generation scanners.
سؤال
The overall goal of the electron-beam CT (EBCT) scanner is to produce low-resolution images of moving organs that are free of artifacts caused by motion.
سؤال
First-generation scanners were first to use fan-beam geometry.
سؤال
High-frequency generators use a low-frequency inverter circuit to convert the low-voltage current from the main power supply to the high-voltage current required by the CT X-ray tube.
سؤال
The Straton X-ray tube was designed by Toshiba Medical Systems.
سؤال
Anistrophic is a term used to describe detector channels that are equal in size.
سؤال
The high-voltage generators of slip-ring scanners are located in the gantry.
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Filtration

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Slip-ring design

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Detector electronics

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Semiconductor

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
سؤال
Please match the following data acquisition concepts. All answer selections will be used just once.

Collimation

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/65
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 4: Data Acquisition Concepts
1
Which scanner allows for continuous rotation of the X-ray tube while the patient moves simultaneously through the gantry aperture?

A) Third-generation conventional scanner
B) Fourth-generation conventional scanner
C) Spiral/helical scanner
D) Dynamic volume scanner
Spiral/helical scanner
2
CT detectors generate a signal that represents the attenuation as the ray moves across the slice. This signal is called:

A) a view sample.
B) an acquisition sample.
C) a profile.
D) a data sample.
a profile.
3
Which X-ray generator is used in modern CT scanners?

A) Single-phase half-wave rectified
B) Single-phase full-wave rectified
C) High-frequency generator
D) Three-phase, six-pulse generator
High-frequency generator
4
Compared with conventional CT scanners, slip-ring scanners offer all of the following advantages except:

A) removal of cable wraparound.
B) elimination of start-stop action.
C) capacity for interrupted acquisition protocols.
D) minimal interscan delays.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
5
Which CT scanner is based on a fan-beam geometry and complete rotation of the X-ray tube and detectors?

A) First-generation scanner
B) Second-generation scanner
C) Third-generation scanner
D) Fourth-generation scanner
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
6
A single ray in computed tomography (CT) is:

A) a beam of X-rays emanating from the X-ray tube.
B) a single straight line path of an X-ray beam.
C) the total attenuation as measured by the detector.
D) a collection of beams gathered by the detector.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which generation of scanners, also called dual-source CT scanners, consists of two X-ray tubes and two sets of detectors?

A) Third generation
B) Fourth generation
C) Fifth generation
D) Sixth generation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
8
In which scanner is the apex of the fan beam located outside the detector?

A) Third-generation scanner
B) Fourth-generation scanner
C) Fifth-generation scanner
D) Sixth-generation scanner
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
9
Which of the following is classified as a high-speed CT scanner?

A) Third-generation scanner
B) Fourth-generation scanner
C) Spiral/helical CT scanner
D) Fifth-generation CT scanner
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
10
Which scanner is based on slip-ring technology?

A) Third-generation conventional scanner
B) Fourth-generation conventional scanner
C) Spiral/helical scanner
D) Fifth-generation scanner
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
11
The scanner that uses an electron gun to "shoot" electrons toward a target ring is the:

A) fifth-generation scanner.
B) fourth-generation scanner.
C) third-generation scanner.
D) spiral/helical scanner.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
12
In one type of fourth-generation CT scanner, the tilting action of the detector ring is referred to as:

A) slip-ring technology.
B) nutating.
C) spiral scanning.
D) helical scanning.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
13
Fourth-generation CT scanners are characterized by:

A) rotate-translate motion and parallel beam geometry.
B) rotate-translate motion and fan-beam geometry.
C) fan-beam geometry and continuous rotation of X-ray tube and detectors
D) fan-beam geometry and complete rotation of X-ray tube around a stationary ring of detectors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
14
Which of the following X-ray tubes is most likely used in spiral/helical CT scanners?

A) A tungsten target fixed anode tube
B) A tungsten target rotating anode tube
C) A molybdenum target rotating anode tube
D) A rotating anode tube with a rhenium tungsten disk
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
15
Which of the following refers to the size, shape, motion, and path traced by the X-ray beam as it scans the patient?

A) Beam geometry
B) Projection profile
C) Data acquisition
D) Detector tracing
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
16
Electromechanical devices made up of rings and brushes to transmit electrical energy across a rotating interface are called:

A) target rings.
B) slip rings.
C) spiral rings.
D) helical rings.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
17
A view in CT is:

A) a specific way in which the patient is positioned with respect to the detectors.
B) the total attenuation as measured by the detector.
C) a collection of rays for one translation across the object.
D) a single straight line path of an X-ray beam.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
18
The total number of data samples per scan or per slice in CT is the:

A) number of data samples per view times the number of views.
B) number of views.
C) number of detectors plus the number of data samples per detector.
D) number of data samples per view plus the number of views.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
19
Which of the following refers to a method by which the patient is systematically scanned by the X-ray tube and detectors to collect enough information for image reconstruction?

A) Beam geometry
B) Data acquisition
C) Sampling
D) Projection reconstruction
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
20
Which scanner results in a volume of the patient being scanned during a single breath-hold (rather than a single slice of tissue)?

A) Spiral/helical scanner
B) Seventh-generation scanner
C) Second-generation scanner
D) First-generation scanner
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
21
Which of the following methods does not affect sampling information?

A) Closely packed detectors
B) Milliamperage-seconds (mAs)
C) Slice thickness
D) Double-dynamic focus
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
22
Which of the following is commonly used in gas-ionization CT detectors?

A) Xenon
B) Oxygen
C) Neon
D) Helium
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
23
What detector innovation allows for acquisition of both low and high energies for every exposure in CT imaging?

A) Stellar detector
B) Third-generation detector
C) Photon counting detector
D) Dual-layer detector
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
24
What provides doubling sampling by obtaining two overlapping slices for each detector row per 360-degree rotation?

A) z-flying focal spot technique
B) Double-dynamic focus
C) Quarter-shifted detection
D) Aliasing method
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
25
The following crystals have been used in scintillation CT detectors except:

A) bismuth germinate.
B) calcium tungstate.
C) calcium fluoride.
D) sodium iodide (NaI).
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
26
Photodiodes are now used in CT scintillation detectors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
27
Which of the following refers to the ability of the CT detector to capture, absorb, and convert X-ray photons into electrical energy?

A) Efficiency
B) Stability
C) Response time
D) Dynamic range
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
28
The data acquisition system (DAS) performs each of the following functions except:

A) measures the transmitted radiation beam.
B) encodes these measurements into binary data.
C) powers the rotating components of the gantry.
D) transmits the binary data to the computer.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
29
The speed with which a CT detector can detect an X-ray event and recover to detect another event is the:

A) response time.
B) stability.
C) efficiency.
D) dynamic range.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
30
The ratio of the largest signal to the smallest signal measured by a CT detector is the:

A) response time.
B) dynamic range.
C) efficiency.
D) stability.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
31
The purpose of collimation in CT is each of the following except:

A) create an homogenous beam.
B) to protect the patient.
C) to ensure a constant beam width at the detector.
D) to reduce scatter radiation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
32
The slice thickness in CT is determined by the:

A) focal spot.
B) anode.
C) collimator height.
D) collimator width.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
33
All of the following are radiation beams produced by an X-ray tube designed for CT except:

A) homogeneous beam.
B) heterogeneous beam.
C) polychromatic beam.
D) polyenergetic beam.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
34
What category of multirow detector array utilizes an isotropic design?

A) Adaptive array detectors
B) Matrix array detectors
C) Unilateral array detectors
D) Identical array detectors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
35
Gas-ionization CT detectors convert X-ray photons into electrical signals with no light conversion process in-between.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
36
Which detector characteristic refers to the steadiness of the detector response?

A) Efficiency
B) Stability
C) Response time
D) Dynamic range
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
37
What style of filter is common in CT filtration because it compensates for the difference in beam path length through the axial plane of the object such that a more uniform fluence can be delivered to the detector?

A) Straight filter
B) Bowtie filter
C) Cone filter
D) Star filter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
38
What design of collimation is influenced by the size of the focal spot?

A) Prepatient collimation
B) Postpatient collimation
C) Predetector collimation
D) Postdetector collimation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
39
The main purpose of a filter used in CT is to:

A) reduce the intensity of the beam at the detector.
B) make the beam less uniform at the detector.
C) decrease the mean energy at the detector.
D) protect the patient.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
40
Scintillation detectors convert X-ray photons to light and subsequently to electrical signals.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
41
Afterglow refers to the persistence of the image even after the radiation has been turned off.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
42
Adaptive section collimation is a design to overcome overscanning, an issue of exposing the patient outside the imaged range which occurs for spiral CT with multirow detectors at the start and the end of the scan.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
43
Please match the following data acquisition concepts. All answer selections will be used just once.

Ionization detector

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
44
Multirow CT detectors fall into two categories, namely, matrix array detectors and pixel array detectors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
45
The change of attenuation and thickness data into transmission measurement is called efficiency conversion.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
46
Please match the following data acquisition concepts. All answer selections will be used just once.

Scintillation

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
47
Seventh-generation scanners use flat-panel digital area detectors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
48
Contactless slip-ring design uses a conductive wire as its sliding contact.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
49
Optoelectronics refers to the use of lens and light diodes to facilitate data transmission.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
50
Gas-ionization detectors are prone to afterglow problems.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
51
Sixth-generation scanners are referred to as the cine CT scanner because of its high-speed acquisition for imaging the heart and circulation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
52
The configuration of the dual-row detector system results in faster volume coverage compared with single-row CT systems.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
53
Streaking artifacts are the result of too many samples being measured by the detectors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
54
Gas-ionization chambers were first introduced in second-generation scanners.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
55
The overall goal of the electron-beam CT (EBCT) scanner is to produce low-resolution images of moving organs that are free of artifacts caused by motion.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
56
First-generation scanners were first to use fan-beam geometry.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
57
High-frequency generators use a low-frequency inverter circuit to convert the low-voltage current from the main power supply to the high-voltage current required by the CT X-ray tube.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
58
The Straton X-ray tube was designed by Toshiba Medical Systems.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
59
Anistrophic is a term used to describe detector channels that are equal in size.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
60
The high-voltage generators of slip-ring scanners are located in the gantry.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
61
Please match the following data acquisition concepts. All answer selections will be used just once.

Filtration

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
62
Please match the following data acquisition concepts. All answer selections will be used just once.

Slip-ring design

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
63
Please match the following data acquisition concepts. All answer selections will be used just once.

Detector electronics

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
64
Please match the following data acquisition concepts. All answer selections will be used just once.

Semiconductor

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
65
Please match the following data acquisition concepts. All answer selections will be used just once.

Collimation

A)Data acquisition system
B)Flashes of light
C)Beam hardening
D)Xenon gas
E)Slice thickness
F)Photodiode
G)Continuous gantry rotation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 65 في هذه المجموعة.