Deck 31: Charging System Service

ملء الشاشة (f)
exit full mode
سؤال
Resistance on the ground side of a regulator will raise system voltage by the amount of the voltage drop caused by the resistance.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Which of the following statements is LEAST-Likely true?

A)Checking voltage drops as a preventive maintenance measure will catch potential problems before they fully develop.
B)A small amount of voltage drop through the fuse link, which is a smaller wire than the rest of the circuit, is normal.
C)There are no fuse links in the ground circuit, so lower voltage drop (0.1 volt) is desired.
D)When performing a voltage drop test, remember that current must not be running through the circuit.
سؤال
The ____________________ test loads the charging system and measures its current output.
سؤال
A good ____________________ will show high resistance in one direction and low resistance in the opposite direction.
سؤال
While having a discussion, Technician A says that the A-circuit has the regulator in the ground circuit and is the type used most often with electronic systems. Technician B says that it is the B-circuit that is configured that way. Who is correct?

A)A only
B)B only
C)Both A and B
D)Neither A nor B
سؤال
A hot AC generator loses 75% of its rated output.
سؤال
A shorted ____ will have low readings in both directions.

A)diode
B)ohmmeter
C)ferrule
D)rotor
سؤال
Extra resistance in the regulator circuit will cause the battery to have a lower than normal charging voltage.
سؤال
AC generator ground wires are usually braided ground straps. The condition of these wires is as important as the insulated wires because they carry the same current flow.
سؤال
Bad ____ are a common cause of AC generator charging problems.

A)diodes
B)ohmmeters
C)ferrules
D)rotors
سؤال
All of the following statements are true EXCEPT:

A)diodes must be in good condition if the AC generator is to function correctly.
B)one or more leaking diodes will decrease generator output.
C)if more than 0.2 AC volt is found in the B+ output, defective diodes are indicated.
D)diodes prevent AC from leaving the AC generator in the B+ output wire.
سؤال
All of the following statements are true EXCEPT:

A)after the engine starts, the control module or voltage regulator will energize the AC generator field and keep voltage at a predetermined level for about 30 seconds.
B)a defective electronic voltage regulator or computer is not a typical cause of a low charge problem.
C)the speed of an AC generator determines its output.
D)at idle, an AC generator is not capable of making maximum output.
سؤال
Which of the following is LEAST-Likely to cause you to replace a rotor?

A)A reading below specs indicates a shorted rotor.
B)High resistance mean connections are corroded.
C)The continuity of the rotor winding does not have any opens, shorts, or grounds.
D)Infinite resistance means the rotor is open.
سؤال
While having a discussion, Technician A says that if you replace a battery simply because it is old, this will not solve a charging problem caused by something else. Technician B says that a new battery is the only solution. Who is correct?

A)A only
B)B only
C)Both A and B
D)Neither A nor B
سؤال
When there is excessive AC output coming from an AC generator, a car radio sometimes makes a whining sound like a siren.
سؤال
The tool MOST-Likely used to look at AC generator patterns is a(n):

A)alternator
B)lab scope
C)diode
D)regulator
سؤال
The ____________________ test checks to see that the voltage regulator is energizing the rotor field and is not allowing the AC generator to overcharge.
سؤال
A(n) ____________________ regulator has its regulator between the positive feed (insulated side) and the field coil, which is grounded inside of the AC generator.
سؤال
____________________ tests check for excessive resistance in the ground and insulated circuits by measuring voltage drop.
سؤال
The test MOST-Likely used to eliminate voltage regulation and fully energize the rotor is the:

A)charging system output test
B)circuit resistance test
C)voltage test
D)full-field test
سؤال
What test would you perform to determine if an AC generator field is strong?
سؤال
What possible problems can be caused by a loose drive belt?
سؤال
What are the steps involved in testing the charging system?
سؤال
What precautions should you take when performing an alternator test?
سؤال
List four charging system complaints.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 31: Charging System Service
1
Resistance on the ground side of a regulator will raise system voltage by the amount of the voltage drop caused by the resistance.
True
2
Which of the following statements is LEAST-Likely true?

A)Checking voltage drops as a preventive maintenance measure will catch potential problems before they fully develop.
B)A small amount of voltage drop through the fuse link, which is a smaller wire than the rest of the circuit, is normal.
C)There are no fuse links in the ground circuit, so lower voltage drop (0.1 volt) is desired.
D)When performing a voltage drop test, remember that current must not be running through the circuit.
D
3
The ____________________ test loads the charging system and measures its current output.
charging system output
4
A good ____________________ will show high resistance in one direction and low resistance in the opposite direction.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
While having a discussion, Technician A says that the A-circuit has the regulator in the ground circuit and is the type used most often with electronic systems. Technician B says that it is the B-circuit that is configured that way. Who is correct?

A)A only
B)B only
C)Both A and B
D)Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
A hot AC generator loses 75% of its rated output.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
A shorted ____ will have low readings in both directions.

A)diode
B)ohmmeter
C)ferrule
D)rotor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
Extra resistance in the regulator circuit will cause the battery to have a lower than normal charging voltage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
AC generator ground wires are usually braided ground straps. The condition of these wires is as important as the insulated wires because they carry the same current flow.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
Bad ____ are a common cause of AC generator charging problems.

A)diodes
B)ohmmeters
C)ferrules
D)rotors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
All of the following statements are true EXCEPT:

A)diodes must be in good condition if the AC generator is to function correctly.
B)one or more leaking diodes will decrease generator output.
C)if more than 0.2 AC volt is found in the B+ output, defective diodes are indicated.
D)diodes prevent AC from leaving the AC generator in the B+ output wire.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
All of the following statements are true EXCEPT:

A)after the engine starts, the control module or voltage regulator will energize the AC generator field and keep voltage at a predetermined level for about 30 seconds.
B)a defective electronic voltage regulator or computer is not a typical cause of a low charge problem.
C)the speed of an AC generator determines its output.
D)at idle, an AC generator is not capable of making maximum output.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of the following is LEAST-Likely to cause you to replace a rotor?

A)A reading below specs indicates a shorted rotor.
B)High resistance mean connections are corroded.
C)The continuity of the rotor winding does not have any opens, shorts, or grounds.
D)Infinite resistance means the rotor is open.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
While having a discussion, Technician A says that if you replace a battery simply because it is old, this will not solve a charging problem caused by something else. Technician B says that a new battery is the only solution. Who is correct?

A)A only
B)B only
C)Both A and B
D)Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
When there is excessive AC output coming from an AC generator, a car radio sometimes makes a whining sound like a siren.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
The tool MOST-Likely used to look at AC generator patterns is a(n):

A)alternator
B)lab scope
C)diode
D)regulator
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
The ____________________ test checks to see that the voltage regulator is energizing the rotor field and is not allowing the AC generator to overcharge.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
A(n) ____________________ regulator has its regulator between the positive feed (insulated side) and the field coil, which is grounded inside of the AC generator.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
____________________ tests check for excessive resistance in the ground and insulated circuits by measuring voltage drop.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
The test MOST-Likely used to eliminate voltage regulation and fully energize the rotor is the:

A)charging system output test
B)circuit resistance test
C)voltage test
D)full-field test
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
What test would you perform to determine if an AC generator field is strong?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
What possible problems can be caused by a loose drive belt?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
What are the steps involved in testing the charging system?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
What precautions should you take when performing an alternator test?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
List four charging system complaints.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.