Deck 14: Transformer Connections for Three-Phase Circuits

ملء الشاشة (f)
exit full mode
سؤال
In a T connection, one transformer is generally referred to as the main transformer and the other is called the ____________________ transformer.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
How are primary windings connected?
سؤال
Determining whether a problem with harmonics exists in a three-phase system is similar to determining the problem in a single-phase system.
سؤال
In general, the low-voltage winding leads are not marked.
سؤال
What is the purpose of a harmonic analyzer?
سؤال
A(n) ____________________ wire is added to eliminate unbalanced voltages.
سؤال
What procedure should be used to make the low-voltage connections?
سؤال
A(n) ____________________ connection is used when three single-phase transformers are used to step down as three-phase voltage of 2400 V to 240 V, three phase.
سؤال
The primary side of the delta-connected transformer may be connected so as to reverse the ____________________ of one of its legs.
سؤال
List three general procedures for dealing with harmonics.
سؤال
It is generally not practical to remove the equipment causing the harmonic distortion, so other methods must be employed.
سؤال
The most accurate method for determining whether there is a harmonics problem is to use a(n) ____________________.
سؤال
The wye-wye connection cannot be used in those applications where the load on the secondary side is balanced.
سؤال
When two or three single-phase transformers are used to transform voltages on a three-phase system, they are known as a transformer connection.
سؤال
List two advantages of a 277/480-V, three-phase, four-wire system.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 14: Transformer Connections for Three-Phase Circuits
1
In a T connection, one transformer is generally referred to as the main transformer and the other is called the ____________________ transformer.
teaser
2
How are primary windings connected?
The high-voltage primary windings are connected in a closed-delta arrangement. H1 is assumed to be the beginning of each high-voltage winding and H2 is assumed to be the end. The end (H2) of each primary winding is connected to the beginning (H1) of the next primary winding to form a series arrangement. One three-phase line wire is connected to each junction of two windings. In other words, the primary winding of each transformer is connected directly across the line voltage. Each of the three line voltages is 2400 V and the primary winding of each transformer is correctly rated at 2400 V. Once the high-voltage primary connections are made, the three-phase 2400-V input may be energized and tested for the correct phase rotation.
3
Determining whether a problem with harmonics exists in a three-phase system is similar to determining the problem in a single-phase system.
True
4
In general, the low-voltage winding leads are not marked.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is the purpose of a harmonic analyzer?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
A(n) ____________________ wire is added to eliminate unbalanced voltages.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
What procedure should be used to make the low-voltage connections?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
A(n) ____________________ connection is used when three single-phase transformers are used to step down as three-phase voltage of 2400 V to 240 V, three phase.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
The primary side of the delta-connected transformer may be connected so as to reverse the ____________________ of one of its legs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
List three general procedures for dealing with harmonics.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
It is generally not practical to remove the equipment causing the harmonic distortion, so other methods must be employed.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
The most accurate method for determining whether there is a harmonics problem is to use a(n) ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
The wye-wye connection cannot be used in those applications where the load on the secondary side is balanced.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
When two or three single-phase transformers are used to transform voltages on a three-phase system, they are known as a transformer connection.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
List two advantages of a 277/480-V, three-phase, four-wire system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.