Deck 15: Test Equipment

ملء الشاشة (f)
exit full mode
سؤال
The correct piece of test equipment that you would use to determine the quality of the insulation of a motor winding would be a(n) ____.

A) megohmmeter
C) clamp-on ammeter
B) ohmmeter
D) oscilloscope
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
If you were to measure the amount of current flowing in a circuit, you would use a(n) ____.

A) voltmeter
C) ohmmeter
B) ammeter
D) oscilloscope
سؤال
Before using the multimeter, you should visually inspect the meter and test leads thoroughly.
سؤال
When measuring the resistance of a circuit, you should ____.

A) test the circuit energized but not operating
B) test the circuit energized and operating partially
C) test the circuit energized and operating fully
D) test the circuit de-energized
سؤال
With the Volts/Div. switch set to 5 mV, a sine wave measures 5.2 blocks with a 10x probe. The peak-to-peak value of this sine wave is ____.

A) 5.2 V
C) 26 mV
B) 260 mV
D) 5 mV
سؤال
When voltage is measured with the voltmeter portion of a digital multimeter, the leads should be connected ____ to the portion of the circuit being tested.

A) in series
C) in parallel
B) behind
D) in front of
سؤال
Using a 10x probe, one complete cycle of a sine wave spans 1.7 blocks when the Sec/Div switch is set to 5 sec. The frequency of this sine wave is ____.

A) 8.5 Hz
C) 117.65 mHz
B) 85 Hz
D) 1.18 Hz
سؤال
The peak-to-peak value of a sine wave is equal to ____.

A) twice the rms value
C) twice the peak value
B) 0.707 times the rms value
D) 1.14 times the average value
سؤال
Using a 1x probe, one complete cycle of a sine wave spans 2.8 blocks when the Sec/Div. switch is set to 10 msec. The period of this sine wave is ____.

A) 2.8 sec
C) 35.71 msec
B) 28 msec
D) 357.14 msec
سؤال
Oscilloscopes measure voltage with respect to ____.

A) ground
C) resistance
B) current
D) time
سؤال
What is the frequency of a sine wave with a cycle time of 1 msec?

A) 1 MHz
C) 200 mHz
B) 1 kHz
D) 10 kHz
سؤال
If you were to measure the opposition to current flow in a circuit, you would use a(n) ____.

A) voltmeter
C) ohmmeter
B) ammeter
D) oscilloscope
سؤال
The unit of measurement of an AC voltage measured on an oscilloscope is ____.

A) peak
C) average
B) peak to peak
D) rms
سؤال
To measure the load current flowing in a circuit, an ammeter is ____.

A) connected in parallel with the power source
B) connected in parallel with the load
C) connected in series with the load
D) connected to a de-energized circuit
سؤال
With the Volts/Div. switch set to 2 mV, a sine wave measures 6.3 blocks with a 1x probe. The rms value of this sine wave is ____.

A) 4.45 mV
C) 44.5 mV
B) 6.3 mV
D) 12.6 mV
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 15: Test Equipment
1
The correct piece of test equipment that you would use to determine the quality of the insulation of a motor winding would be a(n) ____.

A) megohmmeter
C) clamp-on ammeter
B) ohmmeter
D) oscilloscope
A
2
If you were to measure the amount of current flowing in a circuit, you would use a(n) ____.

A) voltmeter
C) ohmmeter
B) ammeter
D) oscilloscope
B
3
Before using the multimeter, you should visually inspect the meter and test leads thoroughly.
True
4
When measuring the resistance of a circuit, you should ____.

A) test the circuit energized but not operating
B) test the circuit energized and operating partially
C) test the circuit energized and operating fully
D) test the circuit de-energized
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
With the Volts/Div. switch set to 5 mV, a sine wave measures 5.2 blocks with a 10x probe. The peak-to-peak value of this sine wave is ____.

A) 5.2 V
C) 26 mV
B) 260 mV
D) 5 mV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
When voltage is measured with the voltmeter portion of a digital multimeter, the leads should be connected ____ to the portion of the circuit being tested.

A) in series
C) in parallel
B) behind
D) in front of
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
Using a 10x probe, one complete cycle of a sine wave spans 1.7 blocks when the Sec/Div switch is set to 5 sec. The frequency of this sine wave is ____.

A) 8.5 Hz
C) 117.65 mHz
B) 85 Hz
D) 1.18 Hz
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
The peak-to-peak value of a sine wave is equal to ____.

A) twice the rms value
C) twice the peak value
B) 0.707 times the rms value
D) 1.14 times the average value
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
Using a 1x probe, one complete cycle of a sine wave spans 2.8 blocks when the Sec/Div. switch is set to 10 msec. The period of this sine wave is ____.

A) 2.8 sec
C) 35.71 msec
B) 28 msec
D) 357.14 msec
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
Oscilloscopes measure voltage with respect to ____.

A) ground
C) resistance
B) current
D) time
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
What is the frequency of a sine wave with a cycle time of 1 msec?

A) 1 MHz
C) 200 mHz
B) 1 kHz
D) 10 kHz
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
If you were to measure the opposition to current flow in a circuit, you would use a(n) ____.

A) voltmeter
C) ohmmeter
B) ammeter
D) oscilloscope
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
The unit of measurement of an AC voltage measured on an oscilloscope is ____.

A) peak
C) average
B) peak to peak
D) rms
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
To measure the load current flowing in a circuit, an ammeter is ____.

A) connected in parallel with the power source
B) connected in parallel with the load
C) connected in series with the load
D) connected to a de-energized circuit
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
With the Volts/Div. switch set to 2 mV, a sine wave measures 6.3 blocks with a 1x probe. The rms value of this sine wave is ____.

A) 4.45 mV
C) 44.5 mV
B) 6.3 mV
D) 12.6 mV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.