Deck 8: Grounding of Specific Equipment

ملء الشاشة (f)
exit full mode
سؤال
The service equipment for mobile homes must be located within sight of, and not more than ____ from, the exterior wall of the mobile home it serves.

A) 15 feet
B) 20 feet
C) 30 feet
D) 40 feet
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Studies suggest that dairy cattle tend to release more milk in response to voltage differences on exposed conductive surfaces of even a few volts.
سؤال
"Patient Care Vicinity" is defined as a space within a location intended for the examination and treatment of patients, extending _______ beyond the normal location of the patient bed, chair, table, treadmill, or other device that supports the patent and extending vertically to ________ above the floor.

A) 6 feet, 7-1/2 feet
B) 5 feet, 6 feet
C) 7-1/2 feet, 6 feet
D) 6 feet, 9 feet
سؤال
Ungrounded conductors are permitted to be marked with any color other than white, gray, or green.
سؤال
____________________ cable has a bare 16 AWG aluminum bonding strip installed between the conductors and the outer armor and is in intimate contact with the armor for the full length of the cable.
سؤال
____ locations are those that are hazardous because of the presence of combustible dust.

A) Class I
B) Class II
C) Class III
D) Class IV
سؤال
____ grounding paths are required to be provided to ensure one effective ground-fault current path is available and functional in patient care areas.

A) Two
B) Three
C) Four
D) Five
سؤال
Unlisted liquidtight flexible metal conduit may be used as an equipment grounding conductor.
سؤال
____ locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures.

A) Class I
B) Class II
C) Class III
D) Class IV
سؤال
____________________ cable consists of one or more current-carrying conductors, one or more equipment grounding conductors if required, and in some cases optical fibers.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 8: Grounding of Specific Equipment
1
The service equipment for mobile homes must be located within sight of, and not more than ____ from, the exterior wall of the mobile home it serves.

A) 15 feet
B) 20 feet
C) 30 feet
D) 40 feet
C
2
Studies suggest that dairy cattle tend to release more milk in response to voltage differences on exposed conductive surfaces of even a few volts.
False
3
"Patient Care Vicinity" is defined as a space within a location intended for the examination and treatment of patients, extending _______ beyond the normal location of the patient bed, chair, table, treadmill, or other device that supports the patent and extending vertically to ________ above the floor.

A) 6 feet, 7-1/2 feet
B) 5 feet, 6 feet
C) 7-1/2 feet, 6 feet
D) 6 feet, 9 feet
A
4
Ungrounded conductors are permitted to be marked with any color other than white, gray, or green.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
____________________ cable has a bare 16 AWG aluminum bonding strip installed between the conductors and the outer armor and is in intimate contact with the armor for the full length of the cable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
____ locations are those that are hazardous because of the presence of combustible dust.

A) Class I
B) Class II
C) Class III
D) Class IV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
____ grounding paths are required to be provided to ensure one effective ground-fault current path is available and functional in patient care areas.

A) Two
B) Three
C) Four
D) Five
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
Unlisted liquidtight flexible metal conduit may be used as an equipment grounding conductor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
____ locations are those in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures.

A) Class I
B) Class II
C) Class III
D) Class IV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
____________________ cable consists of one or more current-carrying conductors, one or more equipment grounding conductors if required, and in some cases optical fibers.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.