Deck 28: The Defrost Timer

ملء الشاشة (f)
exit full mode
سؤال
The brain of the frost-free appliance is the defrost relay.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Many large commercial refrigeration units often use a separate timer clock to control the defrost cycle.
سؤال
Two basic connections for a defrost timer are: the ____ and the cumulative compressor run timer.

A) electromechanical timer
B) thermal timer
C) continuous run timer
D) countdown timer
سؤال
The motor of the ____ is connected directly to the power line and runs at all times.

A) electromechanical timer
B) continuous run timer
C) thermal timer
D) cumulative compressor run timer
سؤال
The motor of the cumulative compressor run timer is permitted to operate only when the compressor is in operation and the ____.

A) thermostat is closed
B) fan is in low speed
C) expansion valve is closed
D) dryer is saturated
سؤال
Defrost timers generally have several timed settings.
سؤال
The defrost timer is operated by a single-phase synchronous motor.
سؤال
The cam can be manually turned to the position so that the defrost cycle is turned on.
سؤال
The defrost timer contacts are operated by a(n) ____ that is gear-driven by an electric wall clock motor.

A) lever
B) shaft
C) eccentric disc
D) cam
سؤال
The function of the defrost timer is to disconnect the compressor from the circuit and connect a resistive heater located near the ____ at regular intervals.

A) evaporator
B) condenser
C) dryer
D) compressor
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 28: The Defrost Timer
1
The brain of the frost-free appliance is the defrost relay.
False
2
Many large commercial refrigeration units often use a separate timer clock to control the defrost cycle.
True
3
Two basic connections for a defrost timer are: the ____ and the cumulative compressor run timer.

A) electromechanical timer
B) thermal timer
C) continuous run timer
D) countdown timer
continuous run timer
4
The motor of the ____ is connected directly to the power line and runs at all times.

A) electromechanical timer
B) continuous run timer
C) thermal timer
D) cumulative compressor run timer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
The motor of the cumulative compressor run timer is permitted to operate only when the compressor is in operation and the ____.

A) thermostat is closed
B) fan is in low speed
C) expansion valve is closed
D) dryer is saturated
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
Defrost timers generally have several timed settings.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
The defrost timer is operated by a single-phase synchronous motor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
The cam can be manually turned to the position so that the defrost cycle is turned on.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
The defrost timer contacts are operated by a(n) ____ that is gear-driven by an electric wall clock motor.

A) lever
B) shaft
C) eccentric disc
D) cam
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
The function of the defrost timer is to disconnect the compressor from the circuit and connect a resistive heater located near the ____ at regular intervals.

A) evaporator
B) condenser
C) dryer
D) compressor