Deck 60: Analog Sensing for Programmable Controllers

ملء الشاشة (f)
exit full mode
سؤال
Ground levels of all equipment must be the same voltage in order to be used.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The Mylar foil type of shielded cable can provide a noise reduction ratio of about ____.

A) 5,000:1
B) 10,000:1
C) 20,000:1
D) 30,000:1
سؤال
Many of the programmable controllers found in industry are designed to accept analog as well as digital inputs.
سؤال
The differential amplifier detects the voltage difference between the pair of signal wires and amplifies this difference.
سؤال
When an analog input is used, such as a thermocouple for measuring temperature, a special module that mounts on the ____ is used.

A) power supply
B) internal relay
C) cable
D) I/O rack
سؤال
Most analog sensors produce strong signals.
سؤال
Common coaxial cable offers ____.

A) very poor noise reduction
B) similar levels of noise reduction as shielded cable
C) good noise reduction
D) the best noise reduction
سؤال
Analog sensors are often used with ____ that can be used to trigger alarms and turn on or off certain processes.

A) programmable valves
B) actuators
C) set point detectors
D) variable switches
سؤال
Try to run signal wiring as far away from power wiring as possible.
سؤال
An electronic device that is often used to help overcome the problem of ____ is the differential amplifier.

A) induced noise
B) static interference
C) harmonic distortion
D) spikes
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 60: Analog Sensing for Programmable Controllers
1
Ground levels of all equipment must be the same voltage in order to be used.
False
2
The Mylar foil type of shielded cable can provide a noise reduction ratio of about ____.

A) 5,000:1
B) 10,000:1
C) 20,000:1
D) 30,000:1
30,000:1
3
Many of the programmable controllers found in industry are designed to accept analog as well as digital inputs.
True
4
The differential amplifier detects the voltage difference between the pair of signal wires and amplifies this difference.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
When an analog input is used, such as a thermocouple for measuring temperature, a special module that mounts on the ____ is used.

A) power supply
B) internal relay
C) cable
D) I/O rack
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
Most analog sensors produce strong signals.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
Common coaxial cable offers ____.

A) very poor noise reduction
B) similar levels of noise reduction as shielded cable
C) good noise reduction
D) the best noise reduction
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
Analog sensors are often used with ____ that can be used to trigger alarms and turn on or off certain processes.

A) programmable valves
B) actuators
C) set point detectors
D) variable switches
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
Try to run signal wiring as far away from power wiring as possible.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
An electronic device that is often used to help overcome the problem of ____ is the differential amplifier.

A) induced noise
B) static interference
C) harmonic distortion
D) spikes
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.