Deck 20: Low-Voltage Remote-Control

ملء الشاشة (f)
exit full mode
سؤال
To simplify connections, the conductor color-coding combinations are red-black-white, red-black-yellow-white, red- black-yellow plus an 18 AWG common , red-black-blue-white, and red-black-yellow-blue-white.

A)orange
B)white
C)blue
D)green
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
When are low-voltage remote-control systems advantageous?
سؤال
NEC 725.136(A) Class 2 circuits in the same raceway or cable as the wiring for light and power.

A)limits the number of
B)limits the voltage of
C)prohibits
D)mandates
سؤال
To install color-coded cables correctly throughout an entire installation, the wires are connected to the , switches, master controls, and panel, like color to like color.

A)conductor
B)relays
C)circuit
D)barrier
سؤال
The low-voltage relay is available in mounting styles.

A)one
B)two
C)three
D)four
سؤال
Switches are available in up to -switch combinations with features such as pilot light, lighted toggle, and being key-operated.

A)2
B)4
C)8
D)10
سؤال
If control requirements are very complex or extensive, a can be installed.

A)master sequencer
B)transistor
C)conventional switch
D)double relay
سؤال
Give one advantage and one disadvantage to installing low-voltage wiring in a raceway.
سؤال
The principle of operation of a master control with rectifiers is based on the fact that a rectifier permits current in direction(s).

A)only one
B)two
C)at least three
D)all
سؤال
What size knockout openings can relays be mounted through? What advantage does the plug-in relay have?
سؤال
identifying the switch's functions can be prepared and inserted in the switch cover.

A)Microchips
B)Directory strips
C)LEDs
D)Relays
سؤال
Most low-voltage, remote-control systems are wired with AWG conductors.

A)10
B)14
C)20
D)32
سؤال
What happens to a transformer in the case of an overload?
سؤال
The switch used in the low-voltage remote-control system is a normally open, , momentary contact switch.

A)double-pole, double-throw
B)single-pole, double-throw
C)single-pole, single-throw
D)double-pole, single-throw
سؤال
In a Class 2 circuit, because the power source of the circuit is limited, overcurrent protection is required.

A)fuse-based
B)circuit-breaker-based
C)no
D)minimum
سؤال
The is used in an installation where several relays are mounted in one enclosure.

A)gasket relay
B)double-throw relay
C)plug-in relay
D)standard relay
سؤال
Give an overview of how a relay-based low-voltage remote-control system operates.
سؤال
A low-voltage remote-control wiring system is operated.

A)resistor
B)capacitor
C)transistor
D)relay
سؤال
The switch used in the low-voltage remote-control system is approximately the size of a standard single-pole switch.

A)one-sixth
B)one-fourth
C)one-third
D)one-half
سؤال
Larger conductors should be used for long runs to minimize the .

A)current
B)voltage drop
C)transformer ratio
D)interrupt rating
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 20: Low-Voltage Remote-Control
1
To simplify connections, the conductor color-coding combinations are red-black-white, red-black-yellow-white, red- black-yellow plus an 18 AWG common , red-black-blue-white, and red-black-yellow-blue-white.

A)orange
B)white
C)blue
D)green
B
2
When are low-voltage remote-control systems advantageous?
A method known as low-voltage remote control is selected because of the number of switches required and because it is desired to have extensive control of the lighting.Low-voltage remote- control systems are available ranging from very simple to very complex.These systems can provide control from multiple locations, automatic timing control, handheld (wireless) controls, occupancy sensors ("On" when motion is detected) and unoccupancy sensors ("Off " with predetermined time-delay when no one is in the room), ceiling and wall mounted sensors, photocell control for security ("On" at dusk, "Off " at dawn), and programmable controls.Federally mandated energy codes are an energy standard for buildings, such as the joint publication ANSI/ASHRAE/IESNA 90.1, the most widely adopted energy standard
3
NEC 725.136(A) Class 2 circuits in the same raceway or cable as the wiring for light and power.

A)limits the number of
B)limits the voltage of
C)prohibits
D)mandates
C
4
To install color-coded cables correctly throughout an entire installation, the wires are connected to the , switches, master controls, and panel, like color to like color.

A)conductor
B)relays
C)circuit
D)barrier
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
5
The low-voltage relay is available in mounting styles.

A)one
B)two
C)three
D)four
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
6
Switches are available in up to -switch combinations with features such as pilot light, lighted toggle, and being key-operated.

A)2
B)4
C)8
D)10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
7
If control requirements are very complex or extensive, a can be installed.

A)master sequencer
B)transistor
C)conventional switch
D)double relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
8
Give one advantage and one disadvantage to installing low-voltage wiring in a raceway.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
9
The principle of operation of a master control with rectifiers is based on the fact that a rectifier permits current in direction(s).

A)only one
B)two
C)at least three
D)all
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
10
What size knockout openings can relays be mounted through? What advantage does the plug-in relay have?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
11
identifying the switch's functions can be prepared and inserted in the switch cover.

A)Microchips
B)Directory strips
C)LEDs
D)Relays
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
12
Most low-voltage, remote-control systems are wired with AWG conductors.

A)10
B)14
C)20
D)32
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
13
What happens to a transformer in the case of an overload?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
14
The switch used in the low-voltage remote-control system is a normally open, , momentary contact switch.

A)double-pole, double-throw
B)single-pole, double-throw
C)single-pole, single-throw
D)double-pole, single-throw
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
15
In a Class 2 circuit, because the power source of the circuit is limited, overcurrent protection is required.

A)fuse-based
B)circuit-breaker-based
C)no
D)minimum
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
16
The is used in an installation where several relays are mounted in one enclosure.

A)gasket relay
B)double-throw relay
C)plug-in relay
D)standard relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
17
Give an overview of how a relay-based low-voltage remote-control system operates.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
18
A low-voltage remote-control wiring system is operated.

A)resistor
B)capacitor
C)transistor
D)relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
19
The switch used in the low-voltage remote-control system is approximately the size of a standard single-pole switch.

A)one-sixth
B)one-fourth
C)one-third
D)one-half
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
20
Larger conductors should be used for long runs to minimize the .

A)current
B)voltage drop
C)transformer ratio
D)interrupt rating
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.