Deck 33: Four-Speed Two-Winding 28consequent Pole29 Motor Controller
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
العب
ملء الشاشة (f)
Deck 33: Four-Speed Two-Winding 28consequent Pole29 Motor Controller
1
A decelerating relay is similar in action to a(n) relay.
A)compelling
B)reversal
C)time
D)accelerating
A)compelling
B)reversal
C)time
D)accelerating
D
2
Compelling relays ensure that the motor starts at the lowest speed.
True
3
In a standard starter, before change is made from a higher to a lower speed, .
A)the overload relay must be reset
B)the contacts must be reclosed
C)the stop button must be pressed
D)the motor must be reversed
A)the overload relay must be reset
B)the contacts must be reclosed
C)the stop button must be pressed
D)the motor must be reversed
C
4
With a compelling relay, the motor is started at low speed and is then accelerated automatically through successive speed steps until the selected speed is reached.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
With an accelerating relay, the motor can be started only by pressing the low-speed push button.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
Multispeed starters are provided with mechanical and electrical interlocking.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
When the starter is equipped with an accelerating relay, .
A)the motor can be started only by pressing the low-speed push button
B)the motor must be started at low speed before a higher speed can be selected
C)the motor is started at low speed and is then accelerated manually
D)the final speed is determined by the button pressed
A)the motor can be started only by pressing the low-speed push button
B)the motor must be started at low speed before a higher speed can be selected
C)the motor is started at low speed and is then accelerated manually
D)the final speed is determined by the button pressed
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
Mechanical and electrical interlocking avoid the possibility of .
A)connecting more than one speed winding at the same time
B)overusing the line
C)connecting more than two speed windings at the same time
D)disconnecting the line
A)connecting more than one speed winding at the same time
B)overusing the line
C)connecting more than two speed windings at the same time
D)disconnecting the line
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
When a compelling relay is used, .
A)the final speed is determined by the button pressed
B)the motor must be started at low speed before a higher speed can be selected
C)the motor is started at low speed and is then accelerated automatically
D)definite time intervals must elapse between each speed change
A)the final speed is determined by the button pressed
B)the motor must be started at low speed before a higher speed can be selected
C)the motor is started at low speed and is then accelerated automatically
D)definite time intervals must elapse between each speed change
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
Four-speed, consequent pole, squirrel cage motors have two reconnectable windings and two speeds for each winding.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck