Deck 7: Compactlogix I-O Configuration

ملء الشاشة (f)
exit full mode
سؤال
In the Fault/Program Action screen, Connection mode is defined as when the controller goes into Program mode or Remote Test mode, or experiences a major recoverable fault or a communications failure.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
When configuring an analog output module and Use Fault Value is selected, the value entered in this parameter will be output.
سؤال
The Program Mode setting for each output point can be set to On, Off, or Hold. How does each setting work when the controller goes into Program mode?
سؤال
The module name is not part of the I/O points tags associated with the module's input points.
سؤال
When entering settings on the Fault/Program screen for a new module, Fault mode is defined as when the controller experiences a major nonrecoverable fault.
سؤال
Briefly describe why problems are likely to occur if a module with a higher version and keying is disabled.
سؤال
The CompactLogix members of the ControlLogix family include the 1768 and the 1769 CompactLogix platforms. Both platforms use the same ____________________ modules.
سؤال
Inhibit Module should not be checked during startups and debugging.
سؤال
When a new I/O module is added to an existing RSLogix 5000 project, the module must be ____________________ before its I/O tags are available for programming.
سؤال
If communications with the controller fail, outputs from the controller are ignored, and the selected Fault mode is used. The Fault mode default setting is ____________________.
سؤال
Which personnel are typically responsible for the manual process of I/O configuration in ControlLogix systems?
سؤال
The electronic keying setting that is typically used by project developers in the early stages of a project when the specific modules have not been installed is ____________________.
سؤال
Briefly describe the Compatible Module selection for electronic keying.
سؤال
When selecting a module to configure, what are the three tab selections available in the Select Module window?
سؤال
If the module is faulted, a hexadecimal error code and explanation displays in the Module Fault box. Additional information can be found by clicking the ____________________ button.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 7: Compactlogix I-O Configuration
1
In the Fault/Program Action screen, Connection mode is defined as when the controller goes into Program mode or Remote Test mode, or experiences a major recoverable fault or a communications failure.
False
2
When configuring an analog output module and Use Fault Value is selected, the value entered in this parameter will be output.
True
3
The Program Mode setting for each output point can be set to On, Off, or Hold. How does each setting work when the controller goes into Program mode?
When the controller goes into Program mode:
• On means this output point will be turned on if it is not already on.
• Off means this output point will be turned off if it is not already off.
• Hold leaves the output point in its current state
4
The module name is not part of the I/O points tags associated with the module's input points.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
When entering settings on the Fault/Program screen for a new module, Fault mode is defined as when the controller experiences a major nonrecoverable fault.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
Briefly describe why problems are likely to occur if a module with a higher version and keying is disabled.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
The CompactLogix members of the ControlLogix family include the 1768 and the 1769 CompactLogix platforms. Both platforms use the same ____________________ modules.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
Inhibit Module should not be checked during startups and debugging.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
When a new I/O module is added to an existing RSLogix 5000 project, the module must be ____________________ before its I/O tags are available for programming.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
If communications with the controller fail, outputs from the controller are ignored, and the selected Fault mode is used. The Fault mode default setting is ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Which personnel are typically responsible for the manual process of I/O configuration in ControlLogix systems?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
The electronic keying setting that is typically used by project developers in the early stages of a project when the specific modules have not been installed is ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
Briefly describe the Compatible Module selection for electronic keying.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
When selecting a module to configure, what are the three tab selections available in the Select Module window?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
If the module is faulted, a hexadecimal error code and explanation displays in the Module Fault box. Additional information can be found by clicking the ____________________ button.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.