Deck 20: Time Response of Reactive Circuits

ملء الشاشة (f)
exit full mode
سؤال
The main purpose of an instrumentation amplifier is to amplify common mode voltage.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A voltage-to-current converter works by controlling current proportional to the input voltage.
سؤال
The voltage gain of an instrumentation amplifier is set with an external resistor.
سؤال
A basic isolation amplifier has two electrically isolated sections.
سؤال
<strong>  Refer to Figure 20-1. Which of these circuits is known as an instrumentation amplifier?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-1. Which of these circuits is known as an instrumentation amplifier?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
A peak detectorʹs output continually changes based on the input.
سؤال
Active limiting and clamping employs an amplifier circuit.
سؤال
A voltage-to-current converter has a JFET in the feedback loop.
سؤال
Most isolation amplifiers use transformer coupling for isolation.
سؤال
<strong>  Refer to Figure 20-1. Which of these circuits is known as an isolation amplifier?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-1. Which of these circuits is known as an isolation amplifier?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
The diode clamper circuit output is an ac signal that has a dc reference point of the peak voltage of
the ac.
سؤال
<strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above. <div style=padding-top: 35px>
Refer to Figure 20-1 (a). If <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above. <div style=padding-top: 35px> and the closed loop gain is 450, the value of the external gain-setting resistor RG is:

A) <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above. <div style=padding-top: 35px>
B) <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above. <div style=padding-top: 35px>
C) <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above. <div style=padding-top: 35px>
D)none of the above.
سؤال
The OTA is a voltage-to-current amplifier.
سؤال
One of the key characteristics of an instrumentation amplifier is its low input impedance.
سؤال
OTA stands for operational transistor amplifier.
سؤال
A voltage limiter that limits both positive and negative peaks uses two zener diodes connected
anode to cathode.
سؤال
<strong>  Refer to Figure 20-1. Which of these circuits is known as a constant-current source?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-1. Which of these circuits is known as a constant-current source?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
The OTA has a ________ input impedance and a ________ CMRR.

A)low, low
B)high, low
C)low, high
D)high, high
سؤال
A basic instrumentation amplifier has three op-amps.
سؤال
An active clamping circuit negates the opposite polarity 0.7 V peak by using two diodes in series.
سؤال
An active limiter includes an op-amp which:

A)works better under loaded conditions.
B)keeps the circuit from oscillating.
C)increases the output voltage.
D)allows a reference level to be set.
سؤال
<strong>  In the classic three op-amp instrumentation amplifier, the differential voltage gain is usually produced by the:</strong> A)second stage. B)output op amp. C)mismatched resistors. D)first stage. <div style=padding-top: 35px>
In the classic three op-amp instrumentation amplifier, the differential voltage gain is usually produced by the:

A)second stage.
B)output op amp.
C)mismatched resistors.
D)first stage.
سؤال
The output of a peak detector is always:

A)equal to the min value of the peak level received since the last reset pulse.
B)70.7% of input.
C)equal to the max value of the peak level received since the last reset pulse.
D)none of the above.
سؤال
An instrumentation amplifier has a high:

A)output impedance.
B)supply voltage.
C)CMRR.
D)power gain.
سؤال
The primary function of the oscillator in an isolation amplifier is to:

A)convert dc to low frequency ac.
B)rectify high frequency ac to dc.
C)convert dc to high frequency ac.
D)produce dual polarity dc voltages for the input to the demodulator.
سؤال
When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:

A) <strong>When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:</strong> A)   B)   C)   D)both A and B. <div style=padding-top: 35px>
B) <strong>When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:</strong> A)   B)   C)   D)both A and B. <div style=padding-top: 35px>
C) <strong>When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:</strong> A)   B)   C)   D)both A and B. <div style=padding-top: 35px>
D)both A and B.
سؤال
In some respects an isolation amplifier is nothing more than an elaborate:

A)instrumentation amplifier.
B)op amp.
C)rectifier and filter.
D)both A and B
سؤال
<strong>  Refer to Figure 20-2 (b). If   the load current   would be:</strong> A)2.08 mA. B)2.08 A. C)208 A. D)20.8 mA. <div style=padding-top: 35px>
Refer to Figure 20-2 (b). If <strong>  Refer to Figure 20-2 (b). If   the load current   would be:</strong> A)2.08 mA. B)2.08 A. C)208 A. D)20.8 mA. <div style=padding-top: 35px> the load current <strong>  Refer to Figure 20-2 (b). If   the load current   would be:</strong> A)2.08 mA. B)2.08 A. C)208 A. D)20.8 mA. <div style=padding-top: 35px> would be:

A)2.08 mA.
B)2.08 A.
C)208 A.
D)20.8 mA.
سؤال
<strong>  Refer to Figure 20-2. Which of these circuits is known as a peak detector?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-2. Which of these circuits is known as a peak detector?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
The voltage gain of an OTA can be calculated using the formula:

A) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
B) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
C) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
D) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)   <div style=padding-top: 35px>
سؤال
<strong>  Refer to Figure 20-2. Which of these circuits is known as a voltage-to-current converter?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-2. Which of these circuits is known as a voltage-to-current converter?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
<strong>  Refer to Figure 20-1 (b). If   the current thru the load   Figure 20-2 would be:</strong> A)227 μA. B)227 mA. C)22.7 mA. D)22.7 μA. <div style=padding-top: 35px>
Refer to Figure 20-1 (b). If <strong>  Refer to Figure 20-1 (b). If   the current thru the load   Figure 20-2 would be:</strong> A)227 μA. B)227 mA. C)22.7 mA. D)22.7 μA. <div style=padding-top: 35px> the current thru the load <strong>  Refer to Figure 20-1 (b). If   the current thru the load   Figure 20-2 would be:</strong> A)227 μA. B)227 mA. C)22.7 mA. D)22.7 μA. <div style=padding-top: 35px> Figure 20-2 would be:

A)227 μA.
B)227 mA.
C)22.7 mA.
D)22.7 μA.
سؤال
<strong>  The input signal for an instrumentation amplifier usually comes from:</strong> A)a transducer. B)an inverting amplifier. C)a wheatstone bridge. D)a differential amplifier. <div style=padding-top: 35px>
The input signal for an instrumentation amplifier usually comes from:

A)a transducer.
B)an inverting amplifier.
C)a wheatstone bridge.
D)a differential amplifier.
سؤال
<strong>  Refer to Figure 20-2 (d). If   the voltage gain would be:</strong> A)62.5. B)625. C)6.25. D)not enough information. <div style=padding-top: 35px>
Refer to Figure 20-2 (d). If <strong>  Refer to Figure 20-2 (d). If   the voltage gain would be:</strong> A)62.5. B)625. C)6.25. D)not enough information. <div style=padding-top: 35px> the voltage gain would be:

A)62.5.
B)625.
C)6.25.
D)not enough information.
سؤال
<strong>  Refer to Figure 20-2. Which of these circuits contains an OTA?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-2. Which of these circuits contains an OTA?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
If an operational transconductance amplifier (OTA) is used as a nonlinear mixer and an audio signal is mixed with an RF signal, the output will be a(n) ________ signal.

A)amplitude modulated (AM)
B)square wave
C)triangular wave
D)frequency modulated (FM)
سؤال
Two zener diodes are used in a limiter circuit to:

A)better regulate a power supply.
B)limit both positive and negative peaks.
C)reduce interelectrode capacitance at high frequencies.
D)none of the above
سؤال
A voltage-to-current converter is used in applications where itʹs necessary to have an output load current that is controlled by ________.

A)input voltage
B)input frequency
C)output resistance
D)input resistance
سؤال
<strong>  Refer to Figure 20-1 (a). If   the   would be:</strong> A)551. B)560. C)56.1. D)5.61. <div style=padding-top: 35px>
Refer to Figure 20-1 (a). If <strong>  Refer to Figure 20-1 (a). If   the   would be:</strong> A)551. B)560. C)56.1. D)5.61. <div style=padding-top: 35px> the <strong>  Refer to Figure 20-1 (a). If   the   would be:</strong> A)551. B)560. C)56.1. D)5.61. <div style=padding-top: 35px> would be:

A)551.
B)560.
C)56.1.
D)5.61.
سؤال
<strong>  Refer to Figure 20-2. Which of these circuits is known as a current-to-voltage converter?</strong> A)(a) B)(b) C)(c) D)(d) <div style=padding-top: 35px>
Refer to Figure 20-2. Which of these circuits is known as a current-to-voltage converter?

A)(a)
B)(b)
C)(c)
D)(d)
سؤال
Which statement best differentiates between limiter and clamper circuits?

A)A limiter limits the both peaks of the output of a given signal, while the clamper limits only one.
B)A limiter sets the limit of the peak output of a given signal while the clamper establishes a dc reference level based on the peak output of the signal from which the ac signal will vary.
C)A limiter sets a dc reference voltage that the ac signal varies upon while the clamper limits the peak output.
D)none of the above
سؤال
How many op-amps does the basic instrumentation amplifier consist of?

A)2
B)3
C)4
D)5
سؤال
An instrumentation amp with one open input:

A)may work correctly in a low noise environment.
B)will not work at all.
C)will allow common-mode noise to be present on the output.
D)both A and C
سؤال
Which op-amp circuit would be useful to switch to an ʺonʺ condition at a specified voltage?

A)instrumentation amp
B)isolation amplifier
C)operational transconductance amplifier configured as a Schmitt-trigger
D)voltage-to-current converter
سؤال
Which statement best describes the action of an OTA amplitude modulator?

A)The power supply bias adjusts the output level.
B)Variations of light intensity adjust the gain of the amplifier.
C)The variations of voltages applied to the current bias input adjusts the gain of the amplifier.
D)The OTA is versatile and can be configured to work in any of these ways.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/45
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 20: Time Response of Reactive Circuits
1
The main purpose of an instrumentation amplifier is to amplify common mode voltage.
False
2
A voltage-to-current converter works by controlling current proportional to the input voltage.
True
3
The voltage gain of an instrumentation amplifier is set with an external resistor.
True
4
A basic isolation amplifier has two electrically isolated sections.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
5
<strong>  Refer to Figure 20-1. Which of these circuits is known as an instrumentation amplifier?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-1. Which of these circuits is known as an instrumentation amplifier?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
6
A peak detectorʹs output continually changes based on the input.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
7
Active limiting and clamping employs an amplifier circuit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
8
A voltage-to-current converter has a JFET in the feedback loop.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
9
Most isolation amplifiers use transformer coupling for isolation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
10
<strong>  Refer to Figure 20-1. Which of these circuits is known as an isolation amplifier?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-1. Which of these circuits is known as an isolation amplifier?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
11
The diode clamper circuit output is an ac signal that has a dc reference point of the peak voltage of
the ac.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
12
<strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above.
Refer to Figure 20-1 (a). If <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above. and the closed loop gain is 450, the value of the external gain-setting resistor RG is:

A) <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above.
B) <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above.
C) <strong>  Refer to Figure 20-1 (a). If   and the closed loop gain is 450, the value of the external gain-setting resistor RG is:</strong> A)   B)   C)   D)none of the above.
D)none of the above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
13
The OTA is a voltage-to-current amplifier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
14
One of the key characteristics of an instrumentation amplifier is its low input impedance.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
15
OTA stands for operational transistor amplifier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
16
A voltage limiter that limits both positive and negative peaks uses two zener diodes connected
anode to cathode.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
17
<strong>  Refer to Figure 20-1. Which of these circuits is known as a constant-current source?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-1. Which of these circuits is known as a constant-current source?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
18
The OTA has a ________ input impedance and a ________ CMRR.

A)low, low
B)high, low
C)low, high
D)high, high
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
19
A basic instrumentation amplifier has three op-amps.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
20
An active clamping circuit negates the opposite polarity 0.7 V peak by using two diodes in series.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
21
An active limiter includes an op-amp which:

A)works better under loaded conditions.
B)keeps the circuit from oscillating.
C)increases the output voltage.
D)allows a reference level to be set.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
22
<strong>  In the classic three op-amp instrumentation amplifier, the differential voltage gain is usually produced by the:</strong> A)second stage. B)output op amp. C)mismatched resistors. D)first stage.
In the classic three op-amp instrumentation amplifier, the differential voltage gain is usually produced by the:

A)second stage.
B)output op amp.
C)mismatched resistors.
D)first stage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
23
The output of a peak detector is always:

A)equal to the min value of the peak level received since the last reset pulse.
B)70.7% of input.
C)equal to the max value of the peak level received since the last reset pulse.
D)none of the above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
24
An instrumentation amplifier has a high:

A)output impedance.
B)supply voltage.
C)CMRR.
D)power gain.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
25
The primary function of the oscillator in an isolation amplifier is to:

A)convert dc to low frequency ac.
B)rectify high frequency ac to dc.
C)convert dc to high frequency ac.
D)produce dual polarity dc voltages for the input to the demodulator.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
26
When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:

A) <strong>When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:</strong> A)   B)   C)   D)both A and B.
B) <strong>When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:</strong> A)   B)   C)   D)both A and B.
C) <strong>When using an OTA in a Schmitt-trigger configuration, the trigger points are controlled by:</strong> A)   B)   C)   D)both A and B.
D)both A and B.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
27
In some respects an isolation amplifier is nothing more than an elaborate:

A)instrumentation amplifier.
B)op amp.
C)rectifier and filter.
D)both A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
28
<strong>  Refer to Figure 20-2 (b). If   the load current   would be:</strong> A)2.08 mA. B)2.08 A. C)208 A. D)20.8 mA.
Refer to Figure 20-2 (b). If <strong>  Refer to Figure 20-2 (b). If   the load current   would be:</strong> A)2.08 mA. B)2.08 A. C)208 A. D)20.8 mA. the load current <strong>  Refer to Figure 20-2 (b). If   the load current   would be:</strong> A)2.08 mA. B)2.08 A. C)208 A. D)20.8 mA. would be:

A)2.08 mA.
B)2.08 A.
C)208 A.
D)20.8 mA.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
29
<strong>  Refer to Figure 20-2. Which of these circuits is known as a peak detector?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-2. Which of these circuits is known as a peak detector?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
30
The voltage gain of an OTA can be calculated using the formula:

A) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)
B) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)
C) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)
D) <strong>The voltage gain of an OTA can be calculated using the formula:</strong> A)   B)   C)   D)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
31
<strong>  Refer to Figure 20-2. Which of these circuits is known as a voltage-to-current converter?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-2. Which of these circuits is known as a voltage-to-current converter?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
32
<strong>  Refer to Figure 20-1 (b). If   the current thru the load   Figure 20-2 would be:</strong> A)227 μA. B)227 mA. C)22.7 mA. D)22.7 μA.
Refer to Figure 20-1 (b). If <strong>  Refer to Figure 20-1 (b). If   the current thru the load   Figure 20-2 would be:</strong> A)227 μA. B)227 mA. C)22.7 mA. D)22.7 μA. the current thru the load <strong>  Refer to Figure 20-1 (b). If   the current thru the load   Figure 20-2 would be:</strong> A)227 μA. B)227 mA. C)22.7 mA. D)22.7 μA. Figure 20-2 would be:

A)227 μA.
B)227 mA.
C)22.7 mA.
D)22.7 μA.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
33
<strong>  The input signal for an instrumentation amplifier usually comes from:</strong> A)a transducer. B)an inverting amplifier. C)a wheatstone bridge. D)a differential amplifier.
The input signal for an instrumentation amplifier usually comes from:

A)a transducer.
B)an inverting amplifier.
C)a wheatstone bridge.
D)a differential amplifier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
34
<strong>  Refer to Figure 20-2 (d). If   the voltage gain would be:</strong> A)62.5. B)625. C)6.25. D)not enough information.
Refer to Figure 20-2 (d). If <strong>  Refer to Figure 20-2 (d). If   the voltage gain would be:</strong> A)62.5. B)625. C)6.25. D)not enough information. the voltage gain would be:

A)62.5.
B)625.
C)6.25.
D)not enough information.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
35
<strong>  Refer to Figure 20-2. Which of these circuits contains an OTA?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-2. Which of these circuits contains an OTA?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
36
If an operational transconductance amplifier (OTA) is used as a nonlinear mixer and an audio signal is mixed with an RF signal, the output will be a(n) ________ signal.

A)amplitude modulated (AM)
B)square wave
C)triangular wave
D)frequency modulated (FM)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
37
Two zener diodes are used in a limiter circuit to:

A)better regulate a power supply.
B)limit both positive and negative peaks.
C)reduce interelectrode capacitance at high frequencies.
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
38
A voltage-to-current converter is used in applications where itʹs necessary to have an output load current that is controlled by ________.

A)input voltage
B)input frequency
C)output resistance
D)input resistance
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
39
<strong>  Refer to Figure 20-1 (a). If   the   would be:</strong> A)551. B)560. C)56.1. D)5.61.
Refer to Figure 20-1 (a). If <strong>  Refer to Figure 20-1 (a). If   the   would be:</strong> A)551. B)560. C)56.1. D)5.61. the <strong>  Refer to Figure 20-1 (a). If   the   would be:</strong> A)551. B)560. C)56.1. D)5.61. would be:

A)551.
B)560.
C)56.1.
D)5.61.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
40
<strong>  Refer to Figure 20-2. Which of these circuits is known as a current-to-voltage converter?</strong> A)(a) B)(b) C)(c) D)(d)
Refer to Figure 20-2. Which of these circuits is known as a current-to-voltage converter?

A)(a)
B)(b)
C)(c)
D)(d)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
41
Which statement best differentiates between limiter and clamper circuits?

A)A limiter limits the both peaks of the output of a given signal, while the clamper limits only one.
B)A limiter sets the limit of the peak output of a given signal while the clamper establishes a dc reference level based on the peak output of the signal from which the ac signal will vary.
C)A limiter sets a dc reference voltage that the ac signal varies upon while the clamper limits the peak output.
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
42
How many op-amps does the basic instrumentation amplifier consist of?

A)2
B)3
C)4
D)5
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
43
An instrumentation amp with one open input:

A)may work correctly in a low noise environment.
B)will not work at all.
C)will allow common-mode noise to be present on the output.
D)both A and C
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
44
Which op-amp circuit would be useful to switch to an ʺonʺ condition at a specified voltage?

A)instrumentation amp
B)isolation amplifier
C)operational transconductance amplifier configured as a Schmitt-trigger
D)voltage-to-current converter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
45
Which statement best describes the action of an OTA amplitude modulator?

A)The power supply bias adjusts the output level.
B)Variations of light intensity adjust the gain of the amplifier.
C)The variations of voltages applied to the current bias input adjusts the gain of the amplifier.
D)The OTA is versatile and can be configured to work in any of these ways.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 45 في هذه المجموعة.