Deck 32: Synchronous Motors

ملء الشاشة (f)
exit full mode
سؤال
What two conditions indicate that normal excitation has taken place?
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
With a self-excited direct generator mounted on the rotor shaft, the amount of excitation current is adjusted by controlling the ____________________ of the generator.
سؤال
A switch called the ____________________ switch is used to connect the excitation current to the motor.
سؤال
The amortisseur winding provides good starting torque and a relatively high starting current.
سؤال
What is a brushless exciter?
سؤال
Synchronous motors are sometimes operated without load to help correct plant power factor. In this mode of operation, they are called ____________________.
سؤال
What is the function of the field discharge resistor?
سؤال
What is the polarized field frequency relay responsible for?
سؤال
The excitation current should be connected to the rotor only after it has accelerated to a speed that is close to synchronous speed.
سؤال
What happens when overexcitation takes place?
سؤال
A synchronous motor cannot be made to produce a leading power factor.
سؤال
The ____________________ relay is actually a timer that contains a current operated coil instead of a voltage operated coil.
سؤال
A special squirrel cage winding, called ____________________, is used to start a synchronous motor.
سؤال
A synchronous motor should never be started with excitation applied to the rotor.
سؤال
Synchronous motors are able to operate at the speed of the rotating magnetic field because they are not induction motors.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 32: Synchronous Motors
1
What two conditions indicate that normal excitation has taken place?
Two conditions indicate when normal excitation has been achieved:
1) The current supplied to the motor drops to its lowest level.
2) The power factor will be 100 percent or unity.
2
With a self-excited direct generator mounted on the rotor shaft, the amount of excitation current is adjusted by controlling the ____________________ of the generator.
field current
3
A switch called the ____________________ switch is used to connect the excitation current to the motor.
field discharge
4
The amortisseur winding provides good starting torque and a relatively high starting current.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is a brushless exciter?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
Synchronous motors are sometimes operated without load to help correct plant power factor. In this mode of operation, they are called ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
What is the function of the field discharge resistor?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
What is the polarized field frequency relay responsible for?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
The excitation current should be connected to the rotor only after it has accelerated to a speed that is close to synchronous speed.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
What happens when overexcitation takes place?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
A synchronous motor cannot be made to produce a leading power factor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
The ____________________ relay is actually a timer that contains a current operated coil instead of a voltage operated coil.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
A special squirrel cage winding, called ____________________, is used to start a synchronous motor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
A synchronous motor should never be started with excitation applied to the rotor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
Synchronous motors are able to operate at the speed of the rotating magnetic field because they are not induction motors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.