Deck 21: Ejector Systems

ملء الشاشة (f)
exit full mode
سؤال
If a sewage pump or ejector serves a single-family dwelling, it must be capable of passing a solid at least 1½ inches in diameter and have a ____ minimum discharge pipe size.

A)1½-inch
B)2-inch
C)3-inch
D)4-inch
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
If a sewage pump or ejector receives discharge from either a water closet or urinal, it must have a minimum capacity of ____ gallons per minute.

A)10
B)15
C)20
D)25
سؤال
The three model codes require that sewage pumps and ejectors have alarms that are audible, visual, or a combination of both for the high-level limit.
سؤال
The vent for a pneumatic ejector must be vented separately to the outdoors.
سؤال
If a sewage pump or ejector serves a commercial building, it must be capable of passing a 2-inch diameter solid and have a _____ minimum discharge pipe size.

A)2-inch
B)3-inch
C)4-inch
D)6-inch
سؤال
Sewage pumping stations are not prone to blockages and require little maintenance.
سؤال
Which of the following is NOT a factor in the selection of a pump?

A)volume of material to be displaced
B)height the material must be lifted
C)average rate of rainfall
D)power supply available
سؤال
_______ are installed as close to the pump as possible so that components can be easily removed from the system.

A)Caps
B)Tees
C)Elbows
D)Unions
سؤال
Full-ported check valves installed in sewage systems to prevent backflow are called __________.

A)RPZs
B)atmospheric-type vacuum breakers
C)double-check valve assemblies
D)backwater valves
سؤال
In which type of basin are the pump and fluid sensors are submerged in the waste?

A)dry
B)wet
C)septic
D)cistern
سؤال
Pneumatic pumps have limited passageways and can become fouled by solid objects, so rotating pumps are a practical solution.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/11
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 21: Ejector Systems
1
If a sewage pump or ejector serves a single-family dwelling, it must be capable of passing a solid at least 1½ inches in diameter and have a ____ minimum discharge pipe size.

A)1½-inch
B)2-inch
C)3-inch
D)4-inch
B
2
If a sewage pump or ejector receives discharge from either a water closet or urinal, it must have a minimum capacity of ____ gallons per minute.

A)10
B)15
C)20
D)25
C
3
The three model codes require that sewage pumps and ejectors have alarms that are audible, visual, or a combination of both for the high-level limit.
True
4
The vent for a pneumatic ejector must be vented separately to the outdoors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
5
If a sewage pump or ejector serves a commercial building, it must be capable of passing a 2-inch diameter solid and have a _____ minimum discharge pipe size.

A)2-inch
B)3-inch
C)4-inch
D)6-inch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
6
Sewage pumping stations are not prone to blockages and require little maintenance.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which of the following is NOT a factor in the selection of a pump?

A)volume of material to be displaced
B)height the material must be lifted
C)average rate of rainfall
D)power supply available
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
8
_______ are installed as close to the pump as possible so that components can be easily removed from the system.

A)Caps
B)Tees
C)Elbows
D)Unions
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
9
Full-ported check valves installed in sewage systems to prevent backflow are called __________.

A)RPZs
B)atmospheric-type vacuum breakers
C)double-check valve assemblies
D)backwater valves
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
10
In which type of basin are the pump and fluid sensors are submerged in the waste?

A)dry
B)wet
C)septic
D)cistern
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
11
Pneumatic pumps have limited passageways and can become fouled by solid objects, so rotating pumps are a practical solution.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 11 في هذه المجموعة.