Deck 19: Plumbing Codes: Vents

ملء الشاشة (f)
exit full mode
سؤال
Which of the following venting methods is allowed by the IPC, but not by the UPC?

A)circuit vent
B)engineered vent systems
C)wet vent, vertical
D)waste stack
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A circuit vent is a vent connecting one or more individual vents with a vent stack or stack vent .
سؤال
An air gap is an unobstructed vertical distance through the free atmosphere between the waste pipe outlet and the flood level rim of the receptacle into which the discharge is flowing.
سؤال
Proper placement and sizing of plumbing vents guard against a reduction of the trap seal .
سؤال
What is developed length?

A)the length of a full trap before air could pass through the trap
B)the highest edge of the receptacle from which water or waste flows into
C)vertical distance between the weir and the top of the dip or trap
D)the length of a pipeline measured along the centerline of the pipe and fittings
سؤال
Which term below is best described as a vent connected at the junction of two fixture drains and serving as a vent for both fixtures?

A)continuous vent
B)common vent
C)dry vent
D)individual vent
سؤال
Which of the following is a group of two or more similar adjacent fixtures that discharge into a common horizontal waste or soil branch?

A)battery of fixtures
B)branch interval
C)combination waste and vent system
D)circuit vent
سؤال
Which type of vent is one from pneumatic sewage ejectors, or similar equipment, which terminates separately to the open air?

A)vent stack
B)sump vent
C)circuit vent
D)relief vent
سؤال
According to code, drainage stacks are to be provided with a relief vent for the purpose of relieving pressure surges from tall stacks once a building reaches how many stories?

A)15
B)10
C)5
D)20
سؤال
Which of the following is a vertical vent pipe installed to provide for the circulation of air to and from the drainage system?

A)trap arm
B)stack venting
C)pressure valves
D)vent stack
سؤال
Which of the following is a one-way check valve that allows air to flow into the piping system without letting any of the sewer gasses leave the DWV system?

A)air break
B)air gap
C)AAV
D)dry vent
سؤال
What kind of venting is used for single waste fixtures where the conventional vertical rise of a vent is impractical?

A)island fixture venting
B)horizontal wet venting
C)circuit venting
D)dry venting
سؤال
What is a drain pipe extending laterally from a soil or waste stack or building drain which receives discharge from one or more fixture drains?

A)horizontal branch
B)flood level rim
C)condensate drain
D)stump drain
سؤال
Which of the following is best described as a vent that does not receive the discharge of any sewage or waste?

A)circuit vent
B)individual vent
C)dry vent
D)relief vent
سؤال
Which of the following venting methods is allowed by the UPC, but not the IPC:

A)combination drain and vent system
B)suds pressure
C)individual vent
D)wet vent, horizontal
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 19: Plumbing Codes: Vents
1
Which of the following venting methods is allowed by the IPC, but not by the UPC?

A)circuit vent
B)engineered vent systems
C)wet vent, vertical
D)waste stack
D
2
A circuit vent is a vent connecting one or more individual vents with a vent stack or stack vent .
False
3
An air gap is an unobstructed vertical distance through the free atmosphere between the waste pipe outlet and the flood level rim of the receptacle into which the discharge is flowing.
True
4
Proper placement and sizing of plumbing vents guard against a reduction of the trap seal .
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is developed length?

A)the length of a full trap before air could pass through the trap
B)the highest edge of the receptacle from which water or waste flows into
C)vertical distance between the weir and the top of the dip or trap
D)the length of a pipeline measured along the centerline of the pipe and fittings
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
Which term below is best described as a vent connected at the junction of two fixture drains and serving as a vent for both fixtures?

A)continuous vent
B)common vent
C)dry vent
D)individual vent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which of the following is a group of two or more similar adjacent fixtures that discharge into a common horizontal waste or soil branch?

A)battery of fixtures
B)branch interval
C)combination waste and vent system
D)circuit vent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
Which type of vent is one from pneumatic sewage ejectors, or similar equipment, which terminates separately to the open air?

A)vent stack
B)sump vent
C)circuit vent
D)relief vent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
According to code, drainage stacks are to be provided with a relief vent for the purpose of relieving pressure surges from tall stacks once a building reaches how many stories?

A)15
B)10
C)5
D)20
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
Which of the following is a vertical vent pipe installed to provide for the circulation of air to and from the drainage system?

A)trap arm
B)stack venting
C)pressure valves
D)vent stack
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Which of the following is a one-way check valve that allows air to flow into the piping system without letting any of the sewer gasses leave the DWV system?

A)air break
B)air gap
C)AAV
D)dry vent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
What kind of venting is used for single waste fixtures where the conventional vertical rise of a vent is impractical?

A)island fixture venting
B)horizontal wet venting
C)circuit venting
D)dry venting
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
What is a drain pipe extending laterally from a soil or waste stack or building drain which receives discharge from one or more fixture drains?

A)horizontal branch
B)flood level rim
C)condensate drain
D)stump drain
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
Which of the following is best described as a vent that does not receive the discharge of any sewage or waste?

A)circuit vent
B)individual vent
C)dry vent
D)relief vent
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
Which of the following venting methods is allowed by the UPC, but not the IPC:

A)combination drain and vent system
B)suds pressure
C)individual vent
D)wet vent, horizontal
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.