Deck 4: Service and Repair: DWV Systems

ملء الشاشة (f)
exit full mode
سؤال
If three fixtures feature a DFU of four, and five fixtures feature a DFU of two, what is the total DFU?

A)14
B)22
C)120
D)11
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Which of the following is NOT an advantage of a siphonic roof drainage system?

A)cost savings
B)reduced pipe sizes
C)recommended design standard
D)reduced roof penetrations
سؤال
Related to determining roof load factor, what is the weight of one cubic foot of water?

A)624 pounds
B)6.28 pounds
C)164 pounds
D)62.48 pounds
سؤال
When would it be appropriate for a plumbing apprentice to design systems?

A)under the general direction of a plumbing contractor
B)under the general direction of a licensed designer
C)when buildings are fast tracked
D)it is not the responsibility of an apprentice
سؤال
All codes typically share the same concept in that minimum vent size is:

A)equal to the drain line size
B)half of the drain line size
C)double the drain line size
D)three-quarters of the drain line size
سؤال
When do drainage fixture unit (DFU)discharge values come into play?

A)when determining minimum pipe sizes for building drains and sewers
B)when calculating load placed on a system based on fixture discharge
C)when sizing venting systems
D)all of the above
سؤال
Which of the following would typically have the smallest DFU value?

A)commercial food waste disposer
B)clothes washer
C)bathtub
D)water closet
سؤال
Most building codes require that secondary roof drainage systems to:

A)be completely separate from primary roof drainage systems
B)be combined with primary roof drainage systems
C)utilize a mix of separate and primary drainage systems
D)none of the above
سؤال
Vent pipe sizes are selected:

A)after plumbing isometric layout is provided
B)before plumbing isometric layout is provided
C)after all drains are installed
D)at the end of the building project
سؤال
Appropriately sized storm drainage systems are based upon what?

A)rainfall rates
B)size of the building
C)total DFU
D)nearby infrastructure
سؤال
Accurate sanitary drainage layouts depend on which factor?

A)DFUs
B)line sizing
C)pipe slope
D)all of the above
سؤال
A technician skilled in the aspect of design has the legal authority to overrule a licensed design professional.
سؤال
Which of the following is a plan provided by a designer or engineer?

A)DFU
B)isometric drawing
C)partial plan view
D)sizing chart
سؤال
There is really never a reason to exceed code when considering installation requirements.
سؤال
Siphonic roof drain systems have many cost advantages.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 4: Service and Repair: DWV Systems
1
If three fixtures feature a DFU of four, and five fixtures feature a DFU of two, what is the total DFU?

A)14
B)22
C)120
D)11
B
2
Which of the following is NOT an advantage of a siphonic roof drainage system?

A)cost savings
B)reduced pipe sizes
C)recommended design standard
D)reduced roof penetrations
C
3
Related to determining roof load factor, what is the weight of one cubic foot of water?

A)624 pounds
B)6.28 pounds
C)164 pounds
D)62.48 pounds
D
4
When would it be appropriate for a plumbing apprentice to design systems?

A)under the general direction of a plumbing contractor
B)under the general direction of a licensed designer
C)when buildings are fast tracked
D)it is not the responsibility of an apprentice
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
All codes typically share the same concept in that minimum vent size is:

A)equal to the drain line size
B)half of the drain line size
C)double the drain line size
D)three-quarters of the drain line size
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
When do drainage fixture unit (DFU)discharge values come into play?

A)when determining minimum pipe sizes for building drains and sewers
B)when calculating load placed on a system based on fixture discharge
C)when sizing venting systems
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which of the following would typically have the smallest DFU value?

A)commercial food waste disposer
B)clothes washer
C)bathtub
D)water closet
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
Most building codes require that secondary roof drainage systems to:

A)be completely separate from primary roof drainage systems
B)be combined with primary roof drainage systems
C)utilize a mix of separate and primary drainage systems
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
Vent pipe sizes are selected:

A)after plumbing isometric layout is provided
B)before plumbing isometric layout is provided
C)after all drains are installed
D)at the end of the building project
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
Appropriately sized storm drainage systems are based upon what?

A)rainfall rates
B)size of the building
C)total DFU
D)nearby infrastructure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Accurate sanitary drainage layouts depend on which factor?

A)DFUs
B)line sizing
C)pipe slope
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
A technician skilled in the aspect of design has the legal authority to overrule a licensed design professional.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of the following is a plan provided by a designer or engineer?

A)DFU
B)isometric drawing
C)partial plan view
D)sizing chart
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
There is really never a reason to exceed code when considering installation requirements.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
Siphonic roof drain systems have many cost advantages.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.