Deck 7: Relay Type Instructions

ملء الشاشة (f)
exit full mode
سؤال
Explain the purpose and functionality of the EXAMINE OFF instruction.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Explain the letters shown in a PLC-5 word or bit address.
سؤال
Because the processor views the N.O. contact instruction as a request to examine a given address for an ON condition, it is referred to as a(n) ___________________ instruction.
سؤال
Discuss the PLC N.O. contact symbol.
سؤال
___________________ contacts in a motor control circuit control the path for current flow to the output.
سؤال
Ladder logic is a good choice for a programming language because it closely resembles the way circuits are hard-wired.
سؤال
What do the terms current flow and power flow indicate?
سؤال
When the N.C. symbol is programmed in a ladder diagram, the processor views it as a request to examine the address of the contact for a(n) ___________________ condition.
سؤال
Whenever the processor sees an N.O. contact in the user program, it views the contact symbol as a request to examine the address of the contact for a(n) ___________________ condition.
سؤال
The EXAMINE OFF instruction is only logically true when the device referenced is ON, or open.
سؤال
There are many more applications and circuits that normally require two- or three-pole devices that now only require single-pole devices when programmed for a PLC.
سؤال
The number of times an input device can be addressed and used in a programmed circuit is limited to eight.
سؤال
When the N.C. symbol is programmed in a ladder diagram, any address that is actually ON becomes logically true and power can flow.
سؤال
Explain the purpose and functionality of the EXAMINE ON instruction.
سؤال
A PLC is normally programmed using a(n) ___________________ logic-type language.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 7: Relay Type Instructions
1
Explain the purpose and functionality of the EXAMINE OFF instruction.
When the N.C. symbol is programmed in a ladder diagram, the processor views it as a request to examine the address of the contact for an OFF condition. Any address that is actually OFF becomes logically true and power can flow. If an N.C. contact has an input address and the real-world input device is open, or OFF, the processor sets the bit to 0, or OFF. As the EXAMINE OFF instruction is looking for an OFF condition, a bit set to 0, or OFF, is a true condition and there would be logic continuity, so power can flow through the contact. If the input device had been closed, or ON, the bit would be set to 1, or ON. The EXAMINE OFF instruction can only be logically true when an OFF condition exists. Any bit set to 1 is viewed as an ON condition which makes an EXAMINE OFF (N.C.) contact false and no power can flow.
2
Explain the letters shown in a PLC-5 word or bit address.
An "I" preceding a word and bit number indicates an input whereas an "O" preceding a word and bit address indicates an output.
3
Because the processor views the N.O. contact instruction as a request to examine a given address for an ON condition, it is referred to as a(n) ___________________ instruction.
EXAMINE ON
4
Discuss the PLC N.O. contact symbol.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
___________________ contacts in a motor control circuit control the path for current flow to the output.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
Ladder logic is a good choice for a programming language because it closely resembles the way circuits are hard-wired.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
What do the terms current flow and power flow indicate?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
When the N.C. symbol is programmed in a ladder diagram, the processor views it as a request to examine the address of the contact for a(n) ___________________ condition.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
Whenever the processor sees an N.O. contact in the user program, it views the contact symbol as a request to examine the address of the contact for a(n) ___________________ condition.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
The EXAMINE OFF instruction is only logically true when the device referenced is ON, or open.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
There are many more applications and circuits that normally require two- or three-pole devices that now only require single-pole devices when programmed for a PLC.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
The number of times an input device can be addressed and used in a programmed circuit is limited to eight.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
When the N.C. symbol is programmed in a ladder diagram, any address that is actually ON becomes logically true and power can flow.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
Explain the purpose and functionality of the EXAMINE ON instruction.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
A PLC is normally programmed using a(n) ___________________ logic-type language.