Deck 10: Contactors, Relays, and Overloads

ملء الشاشة (f)
exit full mode
سؤال
Contacts are made of silver and cadmium, which resist sticking.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
What is an internal compressor overload?
سؤال
Contactors make or break a set of contacts that controls the voltage applied to some load in cooling systems.
سؤال
One of the most common types of line voltage overloads is a(n) _____________________ mounted between two contacts.
سؤال
A(n) ____________________ is an electric device that protects a load from a high ampere draw by breaking a set of contacts.
سؤال
The chemical composition of contacts is such that they operate at cool temperatures of up to ____________________% of their current-carrying capacity.
سؤال
The _________________________ overload breaks the power to a motor.
سؤال
The contacts of a contactor make a complete circuit when the contactor is ____________________, allowing voltage to flow to the controlled load.
سؤال
Contactors are rated by the ampere draw they can carry.
سؤال
Fuses cannot be used to protect wires and non-inductive loads, but they provide adequate protection for inductive loads.
سؤال
Name five devices used in the HVAC industry that can be controlled by a relay.
سؤال
Overloads can be divided into two basic groups. What are these?
سؤال
The contactor contacts must be in good condition to ensure that the proper voltage reaches the load.
سؤال
The diagnosis of a faulty contactor encompasses three sections of the contactor: the coil, the contacts, and the ____________________.
سؤال
A contactor is used to control an electric load in a control system.
سؤال
Coil characteristics depend on the type of wire but not the manner in which it is wound.
سؤال
The simplest form of overload protection is the ____________________.
سؤال
A load that is purely resistive in nature with no coils to cause induction is called a resistive or ____________________ load.
سؤال
Relays cannot be used to open and close a control circuit.
سؤال
Briefly describe the types of loads that a contactor can control.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 10: Contactors, Relays, and Overloads
1
Contacts are made of silver and cadmium, which resist sticking.
True
2
What is an internal compressor overload?
An internal compressor overload is a small device inserted into the motor windings.
3
Contactors make or break a set of contacts that controls the voltage applied to some load in cooling systems.
True
4
One of the most common types of line voltage overloads is a(n) _____________________ mounted between two contacts.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
5
A(n) ____________________ is an electric device that protects a load from a high ampere draw by breaking a set of contacts.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
6
The chemical composition of contacts is such that they operate at cool temperatures of up to ____________________% of their current-carrying capacity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
7
The _________________________ overload breaks the power to a motor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
8
The contacts of a contactor make a complete circuit when the contactor is ____________________, allowing voltage to flow to the controlled load.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
9
Contactors are rated by the ampere draw they can carry.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
10
Fuses cannot be used to protect wires and non-inductive loads, but they provide adequate protection for inductive loads.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
11
Name five devices used in the HVAC industry that can be controlled by a relay.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
12
Overloads can be divided into two basic groups. What are these?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
13
The contactor contacts must be in good condition to ensure that the proper voltage reaches the load.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
14
The diagnosis of a faulty contactor encompasses three sections of the contactor: the coil, the contacts, and the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
15
A contactor is used to control an electric load in a control system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
16
Coil characteristics depend on the type of wire but not the manner in which it is wound.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
17
The simplest form of overload protection is the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
18
A load that is purely resistive in nature with no coils to cause induction is called a resistive or ____________________ load.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
19
Relays cannot be used to open and close a control circuit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
20
Briefly describe the types of loads that a contactor can control.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.