Deck 7: The Polyphase Rectifier

ملء الشاشة (f)
exit full mode
سؤال
When using three-phase rectifiers, the average DC voltage output is ____ than the ____ value of the  AC voltage.

A) lower, RMS
B) higher, RMS
C) lower, peak
D) higher, peak
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Six-phase half wave rectifiers produce two times the ripple as a three-phase full-wave rectifier.
سؤال
There are two types of three-phase rectifiers: the half-wave and the bridge.
سؤال
The three-phase bridge rectifier is often used for industrial applications because it has less ____ than  the half-wave rectifier.

A) drain
B) resistance
C) inversion
D) ripple
سؤال
When a three-phase, half-wave rectifier is used, the average DC voltage can be computed by  multiplying the peak value of voltage by ____.

A) .827
B) 1.169
C) 1.414
D) 4.80
سؤال
When a multi-phase rectifier is used, it is generally connected as a ____.

A) half-wave rectifier
B) full-wave rectifier
C) half-wave inverter
D) half-phase transformer
سؤال
The ripple produced by changing AC voltage into DC voltage can be made much smoother by the use  of ____.

A) fillers
B) inverters
C) filters
D) capacitors
سؤال
The amount of ripple produced by a rectifier can become a matter of great importance; for this reason,   there are rectifiers that operate on 4, 8, or 16 phases.
سؤال
The three-phase bridge type rectifier has a higher average DC voltage than the three-phase, half-wave  rectifier.
سؤال
Industry is operated by three-phase power, so it is necessary to change three-phase alternating current  into direct current.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 7: The Polyphase Rectifier
1
When using three-phase rectifiers, the average DC voltage output is ____ than the ____ value of the  AC voltage.

A) lower, RMS
B) higher, RMS
C) lower, peak
D) higher, peak
B
2
Six-phase half wave rectifiers produce two times the ripple as a three-phase full-wave rectifier.
False
3
There are two types of three-phase rectifiers: the half-wave and the bridge.
True
4
The three-phase bridge rectifier is often used for industrial applications because it has less ____ than  the half-wave rectifier.

A) drain
B) resistance
C) inversion
D) ripple
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
When a three-phase, half-wave rectifier is used, the average DC voltage can be computed by  multiplying the peak value of voltage by ____.

A) .827
B) 1.169
C) 1.414
D) 4.80
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
When a multi-phase rectifier is used, it is generally connected as a ____.

A) half-wave rectifier
B) full-wave rectifier
C) half-wave inverter
D) half-phase transformer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
The ripple produced by changing AC voltage into DC voltage can be made much smoother by the use  of ____.

A) fillers
B) inverters
C) filters
D) capacitors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
The amount of ripple produced by a rectifier can become a matter of great importance; for this reason,   there are rectifiers that operate on 4, 8, or 16 phases.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
The three-phase bridge type rectifier has a higher average DC voltage than the three-phase, half-wave  rectifier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
Industry is operated by three-phase power, so it is necessary to change three-phase alternating current  into direct current.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.