Deck 8: Article 725 of the National Electrical Code; Classification of Circuits

ملء الشاشة (f)
exit full mode
سؤال
Class 2 circuit conductors shall be insulated to a maximum of _________.

A) 30V
B) 90V
C) 100V
D) 150V
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Pipe fill is required for which of the following circuits?

A) Security Alarm circuits
B) Telephone circuits
C) Audio circuits
D) Computer Networking circuits
سؤال
Instrumentation tray cable can be used as a substitute for Class 3 wiring.
سؤال
Multiple Class 2 or Class 3 power supplies can be wired in parallel with each other.
سؤال
Class 2 circuits may be installed in the same enclosure or cable with conductors of Class 3 circuits provided _________.

A) Circuit voltages are not above 150V
B) They are functionally associated
C) The class 2 conductors are insulated to a minimum of 300V
D) The class 2 and Class 3 conductors are insulated to a minimum of 600V
سؤال
All Class 2 conductors may be strapped or attached to the exterior of a conduit.
سؤال
Exterior run Class 2 and Class 3 circuits must maintain a minimum separation of _________ from Class 1 electric light and power circuits.

A) ¼ inch
B) 1 inch
C) 2 inch
D) 6 inch
سؤال
Insulation requirements for Class 1 conductors 18 and 16 AWG must be suitable for 600 V.
سؤال
Class 2 or Class 3 conductors may be run in the same raceway with Class 1 circuits provided _________.

A) They are functionally associated
B) They are separated by a solid and firmly fixed barrier
C) That there is a 2 inch separation between the conductors
D) They are carrying less than 150V
سؤال
Class 1 circuits, that are not functionally associated, must be separated from power conductors by a solid and firmly fixed barrier.
سؤال
Power sources for Class 2 or Class 3 circuits may be derived from ________.

A) A listed or labeled Class 2 or Class 3 power supply or transformer
B) Any inherently limited power supply
C) Any power supply having a maximum output of 100VA
D) Any power supply 150V or less
سؤال
Class 3 power supplies may operate up to a maximum of 1000VA.
سؤال
Class 2 or Class 3 conductors may be installed within enclosures including electric light and power circuits provided _________.

A) The Class 2 and Class 3 circuits are installed as Class 3 and they maintain ¼" separation
B) They are installed as Class 1 circuits
C) The Class 1 circuits are functionally associated and maintain ¼' separation
D) All the above
سؤال
A Power-limited Class 1 circuit may operate at a maximum of _________.

A) 600V, 1000VA
B) 30V, 1000VA
C) 150V, 1000VA
D) 30V, 100VA
سؤال
Signaling circuits include _________.

A) Circuits that activate notification devices
B) Circuits that signal other circuits
C) Circuits that control other circuits
D) Communication circuits
سؤال
If an equipment failure were to introduce a direct life or fire hazard, the circuit must be reclassified as Class 1.
سؤال
The overcurrent protection device for a Class 1 circuits may be rated to _________.

A) 70% of the power supply rating
B) 100% of the power supply rating
C) 167% of the power supply rating
D) 200% of the power supply rating
سؤال
Coaxial cable connecting a video camera to a monitor is an example of integral wiring.
سؤال
Class 3 conductor may be smaller than 18 AWG.
سؤال
Class 1 circuits typically operate from greater voltage and current levels than those of Class 2 or 3 circuits.
سؤال
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
Calculate the total diameter of the TFN conductors.
سؤال
Class 2 or Class 3 audio circuit conductors in accordance with section 640.9 of the NEC, __________ occupy the same cable or raceway with other Class 2 or Class 3 remote control or signaling circuits.

A) Shall not be permitted to
B) Shall
C) Shall be permitted to
D) Must
سؤال
Class 2 AC power supplies between 30V-150V may operate at a maximum of __________.

A) 5mA
B) 50mA
C) 500mA
D) They are not allowed to operate above 30V
سؤال
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
What percentage fill is required by the NEC ?
سؤال
The rating on power-limited tray cable should be rated for_____ V and not less than _______ AWG.

A) 150V, 18AWG
B) 150V, 22AWG
C) 300V, 18AWG
D) 300V, 22 AWG
سؤال
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
What size RNC is needed to accommodate the conductors?
سؤال
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
​ Calculate the total diameter of the XFF conductors.
سؤال
In elevators, power-limited circuits must be installed __________.

A) To maintain a 2 inch separation form class 1 circuits
B) Inside a rigid metal conduit or non-metallic conduit
C) As class 1 wiring
D) In a cable tray
سؤال
A power-limited Class 3 power supply must never exceed _________.

A) 30V, 100VA
B) 150V, 100VA
C) 300V, 100VA
D) 600V, 1000VA
سؤال
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
Calculate the total diameter of the XF conductors.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/30
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 8: Article 725 of the National Electrical Code; Classification of Circuits
1
Class 2 circuit conductors shall be insulated to a maximum of _________.

A) 30V
B) 90V
C) 100V
D) 150V
D
2
Pipe fill is required for which of the following circuits?

A) Security Alarm circuits
B) Telephone circuits
C) Audio circuits
D) Computer Networking circuits
C
3
Instrumentation tray cable can be used as a substitute for Class 3 wiring.
False
4
Multiple Class 2 or Class 3 power supplies can be wired in parallel with each other.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
5
Class 2 circuits may be installed in the same enclosure or cable with conductors of Class 3 circuits provided _________.

A) Circuit voltages are not above 150V
B) They are functionally associated
C) The class 2 conductors are insulated to a minimum of 300V
D) The class 2 and Class 3 conductors are insulated to a minimum of 600V
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
6
All Class 2 conductors may be strapped or attached to the exterior of a conduit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
7
Exterior run Class 2 and Class 3 circuits must maintain a minimum separation of _________ from Class 1 electric light and power circuits.

A) ¼ inch
B) 1 inch
C) 2 inch
D) 6 inch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
8
Insulation requirements for Class 1 conductors 18 and 16 AWG must be suitable for 600 V.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
9
Class 2 or Class 3 conductors may be run in the same raceway with Class 1 circuits provided _________.

A) They are functionally associated
B) They are separated by a solid and firmly fixed barrier
C) That there is a 2 inch separation between the conductors
D) They are carrying less than 150V
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
10
Class 1 circuits, that are not functionally associated, must be separated from power conductors by a solid and firmly fixed barrier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
11
Power sources for Class 2 or Class 3 circuits may be derived from ________.

A) A listed or labeled Class 2 or Class 3 power supply or transformer
B) Any inherently limited power supply
C) Any power supply having a maximum output of 100VA
D) Any power supply 150V or less
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
12
Class 3 power supplies may operate up to a maximum of 1000VA.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
13
Class 2 or Class 3 conductors may be installed within enclosures including electric light and power circuits provided _________.

A) The Class 2 and Class 3 circuits are installed as Class 3 and they maintain ¼" separation
B) They are installed as Class 1 circuits
C) The Class 1 circuits are functionally associated and maintain ¼' separation
D) All the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
14
A Power-limited Class 1 circuit may operate at a maximum of _________.

A) 600V, 1000VA
B) 30V, 1000VA
C) 150V, 1000VA
D) 30V, 100VA
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
15
Signaling circuits include _________.

A) Circuits that activate notification devices
B) Circuits that signal other circuits
C) Circuits that control other circuits
D) Communication circuits
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
16
If an equipment failure were to introduce a direct life or fire hazard, the circuit must be reclassified as Class 1.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
17
The overcurrent protection device for a Class 1 circuits may be rated to _________.

A) 70% of the power supply rating
B) 100% of the power supply rating
C) 167% of the power supply rating
D) 200% of the power supply rating
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
18
Coaxial cable connecting a video camera to a monitor is an example of integral wiring.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
19
Class 3 conductor may be smaller than 18 AWG.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
20
Class 1 circuits typically operate from greater voltage and current levels than those of Class 2 or 3 circuits.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
21
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
Calculate the total diameter of the TFN conductors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
22
Class 2 or Class 3 audio circuit conductors in accordance with section 640.9 of the NEC, __________ occupy the same cable or raceway with other Class 2 or Class 3 remote control or signaling circuits.

A) Shall not be permitted to
B) Shall
C) Shall be permitted to
D) Must
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
23
Class 2 AC power supplies between 30V-150V may operate at a maximum of __________.

A) 5mA
B) 50mA
C) 500mA
D) They are not allowed to operate above 30V
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
24
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
What percentage fill is required by the NEC ?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
25
The rating on power-limited tray cable should be rated for_____ V and not less than _______ AWG.

A) 150V, 18AWG
B) 150V, 22AWG
C) 300V, 18AWG
D) 300V, 22 AWG
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
26
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
What size RNC is needed to accommodate the conductors?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
27
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
​ Calculate the total diameter of the XFF conductors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
28
In elevators, power-limited circuits must be installed __________.

A) To maintain a 2 inch separation form class 1 circuits
B) Inside a rigid metal conduit or non-metallic conduit
C) As class 1 wiring
D) In a cable tray
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
29
A power-limited Class 3 power supply must never exceed _________.

A) 30V, 100VA
B) 150V, 100VA
C) 300V, 100VA
D) 600V, 1000VA
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
30
You have a Rigid PVC conduit (RNC), schedule 80, that is required to hold the following conductors; six -18AWG TFN, ten -18AWG XFF and four -16AWG XF.   Answer the questions below.
Calculate the total diameter of the XF conductors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 30 في هذه المجموعة.