Deck 14: Automatic Control Components and Applications

ملء الشاشة (f)
exit full mode
سؤال
A helix coil is used in some applications to sense temperature in a moving air stream.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A low pressure control has a "high event" and a "differential" setting. The technician wants the system to turn on at 28 psig and shut down at 2 psig. What would be the proper settings?

A) High event: 28 psig, differential: 2 psig.
B) High event: 2 psig, differential: 2 psig.
C) High event: 28 psig, differential: 26 psig.
D) High event: 2 psig, differential: 28 psig.
سؤال
The difference between system overshoot and system lag is called ____.

A) room temperature
B) temperature rise
C) temperature swing
D) room swing
سؤال
The heater in the thermostat control circuit in the cooling mode is active when the ____.

A) cooling contact is open
B) cooling contact is closed
C) fan switch is open
D) fan switch is closed
سؤال
To prove that the combustion blower motor is operating before ignition, a ____ would be used.

A) toggle switch
B) pressure differential switch
C) push button switch
D) sail switch
سؤال
The purpose of a heat anticipator is to ____.

A) anticipate a sudden rise in temperature
B) keep the thermostat warm
C) reduce the temperature swing of a conditioned space
D) ensure that the system transformer does not overheat
سؤال
If the suction pressure of a system is 60 psig and the oil pump outlet is 85 psig, what is the net oil pressure?

A) 60 psig
B) 25 psig
C) 85 psig
D) 145 psig
سؤال
To obtain an accurate reading of a fluid in a large pipe, a technician should ____.

A) strap a dial-type pocket thermometer to the pipe
B) use a digital thermometer in a glass of ice water
C) use a permanently mounted thermometer in a well
D) Any of the above will work fine.
سؤال
Where would a water regulating valve that is controlling head pressure be installed?

A) Water circuit at inlet of condenser.
B) Discharge line at outlet of compressor.
C) Suction line.
D) Liquid line close to the condenser.
سؤال
Oil pressure safety controls measure the difference in pressure to establish ____.

A) the compressor is running
B) the oil pump is running
C) that negative oil pressure is present
D) that positive oil pressure is present
سؤال
The cold anticipator is wired in ____ with the mercury bulb cooling contacts and is energized during the off cycle.

A) parallel
B) series
C) sequence
D) opposition
سؤال
To properly set the heat anticipator, the ____  must determine what the current flow is through the heating control circuit when the furnace is operating in a steady state condition .

A) manufacturer
B) homeowner
C) electrician
D) heating technician
سؤال
The cold anticipator starts the cooling system early to allow the air-conditioning system to get up to capacity when needed.
سؤال
To control ice build-up on a heat pump outdoor coil in the heating cycle, a ____ is attached to a large diaphragm.

A) toggle switch
B) micro-switch
C) push button switch
D) sail switch
سؤال
The heat anticipator in the thermostat control circuit in the heating mode is active when the ____.

A) heating contact is open
B) heating contact is closed
C) fan switch is open
D) fan switch is closed
سؤال
The heat anticipator in a thermostat prevents the temperature in the conditioned space from rising above the thermostat setting.
سؤال
When a water regulating valve is used to control the head pressure of a water-cooled system, the valve's spring is acting against which pressure to modulate the water flow?

A) Head pressure of the system.
B) Water pressure.
C) Suction pressure.
D) Atmospheric pressure.
سؤال
Line voltage thermostats have heavier contacts and use which type of sensing element?

A) Bimetal.
B) Bellows.
C) Remote bulb.
D) All of the above.
سؤال
What is meant by the term "detent"?

A) Slow motion of a contact to ensure good electrical contact.
B) Rapid making and breaking of a contact.
C) The compensation furnished by heaters in the thermostat.
D) The control of the blower in the air handler.
سؤال
The advantage of using a thermistor-type thermometer over a mercury-filled thermometer for measuring refrigerant line temperature is that the thermistor-type does not have to be insulated.
سؤال
The term used to describe when the temperature of a heated room rises above the thermostat's set point is ____________________.
سؤال
What type of control would be used to cycle compressors on and off in response to evaporator pressures that indirectly control box temperatures?
سؤال
The term used to describe when the temperature of a heated room falls below the thermostat's set point is called ____________________.
سؤال
Explain the most accurate way to measure the current through the heat anticipator.
سؤال
Explain why the thermistor type sensor is normally embedded in the motor windings.
سؤال
Many natural gas fired heating units operate at a manifold pressure of 3.5 in. WC .
سؤال
High pressure control contacts are normally ____________________ type.
سؤال
Where is the thermistor motor overload device usually positioned?
سؤال
An oil pressure safety control usually has a 90-second time delay built into it. Why?
سؤال
A dual pressure control is actually a low pressure control and a high pressure control connected in parallel with each other.
سؤال
List four reasons why low voltage controls are usually found on residential air conditioning systems?
سؤال
The heater that functions in a thermostat in the cooling mode is called the ____________________.
سؤال
What device may be used to ensure that air is flowing through a duct before an electric strip heater is energized?
سؤال
The heater that functions in a thermostat in the heating mode is called the ____________________.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/34
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 14: Automatic Control Components and Applications
1
A helix coil is used in some applications to sense temperature in a moving air stream.
True
2
A low pressure control has a "high event" and a "differential" setting. The technician wants the system to turn on at 28 psig and shut down at 2 psig. What would be the proper settings?

A) High event: 28 psig, differential: 2 psig.
B) High event: 2 psig, differential: 2 psig.
C) High event: 28 psig, differential: 26 psig.
D) High event: 2 psig, differential: 28 psig.
C
3
The difference between system overshoot and system lag is called ____.

A) room temperature
B) temperature rise
C) temperature swing
D) room swing
C
4
The heater in the thermostat control circuit in the cooling mode is active when the ____.

A) cooling contact is open
B) cooling contact is closed
C) fan switch is open
D) fan switch is closed
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
5
To prove that the combustion blower motor is operating before ignition, a ____ would be used.

A) toggle switch
B) pressure differential switch
C) push button switch
D) sail switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
6
The purpose of a heat anticipator is to ____.

A) anticipate a sudden rise in temperature
B) keep the thermostat warm
C) reduce the temperature swing of a conditioned space
D) ensure that the system transformer does not overheat
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
7
If the suction pressure of a system is 60 psig and the oil pump outlet is 85 psig, what is the net oil pressure?

A) 60 psig
B) 25 psig
C) 85 psig
D) 145 psig
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
8
To obtain an accurate reading of a fluid in a large pipe, a technician should ____.

A) strap a dial-type pocket thermometer to the pipe
B) use a digital thermometer in a glass of ice water
C) use a permanently mounted thermometer in a well
D) Any of the above will work fine.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
9
Where would a water regulating valve that is controlling head pressure be installed?

A) Water circuit at inlet of condenser.
B) Discharge line at outlet of compressor.
C) Suction line.
D) Liquid line close to the condenser.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
10
Oil pressure safety controls measure the difference in pressure to establish ____.

A) the compressor is running
B) the oil pump is running
C) that negative oil pressure is present
D) that positive oil pressure is present
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
11
The cold anticipator is wired in ____ with the mercury bulb cooling contacts and is energized during the off cycle.

A) parallel
B) series
C) sequence
D) opposition
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
12
To properly set the heat anticipator, the ____  must determine what the current flow is through the heating control circuit when the furnace is operating in a steady state condition .

A) manufacturer
B) homeowner
C) electrician
D) heating technician
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
13
The cold anticipator starts the cooling system early to allow the air-conditioning system to get up to capacity when needed.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
14
To control ice build-up on a heat pump outdoor coil in the heating cycle, a ____ is attached to a large diaphragm.

A) toggle switch
B) micro-switch
C) push button switch
D) sail switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
15
The heat anticipator in the thermostat control circuit in the heating mode is active when the ____.

A) heating contact is open
B) heating contact is closed
C) fan switch is open
D) fan switch is closed
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
16
The heat anticipator in a thermostat prevents the temperature in the conditioned space from rising above the thermostat setting.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
17
When a water regulating valve is used to control the head pressure of a water-cooled system, the valve's spring is acting against which pressure to modulate the water flow?

A) Head pressure of the system.
B) Water pressure.
C) Suction pressure.
D) Atmospheric pressure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
18
Line voltage thermostats have heavier contacts and use which type of sensing element?

A) Bimetal.
B) Bellows.
C) Remote bulb.
D) All of the above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
19
What is meant by the term "detent"?

A) Slow motion of a contact to ensure good electrical contact.
B) Rapid making and breaking of a contact.
C) The compensation furnished by heaters in the thermostat.
D) The control of the blower in the air handler.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
20
The advantage of using a thermistor-type thermometer over a mercury-filled thermometer for measuring refrigerant line temperature is that the thermistor-type does not have to be insulated.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
21
The term used to describe when the temperature of a heated room rises above the thermostat's set point is ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
22
What type of control would be used to cycle compressors on and off in response to evaporator pressures that indirectly control box temperatures?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
23
The term used to describe when the temperature of a heated room falls below the thermostat's set point is called ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
24
Explain the most accurate way to measure the current through the heat anticipator.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
25
Explain why the thermistor type sensor is normally embedded in the motor windings.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
26
Many natural gas fired heating units operate at a manifold pressure of 3.5 in. WC .
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
27
High pressure control contacts are normally ____________________ type.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
28
Where is the thermistor motor overload device usually positioned?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
29
An oil pressure safety control usually has a 90-second time delay built into it. Why?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
30
A dual pressure control is actually a low pressure control and a high pressure control connected in parallel with each other.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
31
List four reasons why low voltage controls are usually found on residential air conditioning systems?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
32
The heater that functions in a thermostat in the cooling mode is called the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
33
What device may be used to ensure that air is flowing through a duct before an electric strip heater is energized?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
34
The heater that functions in a thermostat in the heating mode is called the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 34 في هذه المجموعة.