Deck 15: Troubleshooting Basic Controls
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/33
العب
ملء الشاشة (f)
Deck 15: Troubleshooting Basic Controls
1
If an air conditioning system is calling for cooling and the compressor is running but the indoor (evaporator) fan is not running, which terminal on the thermostat will the technician most likely check first?
A) G
B) R
C) Y
D) W
A) G
B) R
C) Y
D) W
A
2
Transformers are rated using ____.
A) volt-amperes
B) volt-ohms
C) amperes-ohms
D) volt-resistance
A) volt-amperes
B) volt-ohms
C) amperes-ohms
D) volt-resistance
A
3
A control can be which of the following?
A) electrical
B) mechanical
C) electrical and mechanical
D) all of the above
A) electrical
B) mechanical
C) electrical and mechanical
D) all of the above
D
4
The cooling anticipator in a thermostat is usually an adjustable type.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
5
When checking thermostat circuits, an insulated jumper wire is a handy tool.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
6
Electrical controls are divided into two categories: power-consuming and _________________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
7
The _____ is nothing more than a set of switches.
A) transformer
B) coil
C) motor
D) thermostat
A) transformer
B) coil
C) motor
D) thermostat
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
8
A(n) ____ is the easiest diagram to use to follow a circuit. This diagram normally can be studied briefly, and the circuit function should become obvious.
A) pictorial diagram
B) ladder diagram
C) layout
D) oblique drawing
A) pictorial diagram
B) ladder diagram
C) layout
D) oblique drawing
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
9
The continuity through a heat relay is checked using a(n) ____.
A) ohmmeter
B) voltmeter
C) clamp-on ammeter
D) micron gauge
A) ohmmeter
B) voltmeter
C) clamp-on ammeter
D) micron gauge
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
10
An electrical diagram showing the approximate location of the components is called a(n) ____.
A) pictorial diagram
B) ladder diagram
C) layout
D) oblique drawing
A) pictorial diagram
B) ladder diagram
C) layout
D) oblique drawing
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
11
When conditions are correct, the rheostat will pass power through the device onto the system components to be controlled.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
12
The line side of a switch is the ____.
A) side the load is connected to
B) neutral side of the circuit
C) side the power source is connected to
D) side with the white wire
A) side the load is connected to
B) neutral side of the circuit
C) side the power source is connected to
D) side with the white wire
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
13
The heat anticipator in a thermostat is usually an adjustable type.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
14
When using a ten-wrap multiplier, the reading on the meter must be multiplied by ten.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
15
A 10-wrap amperage multiplier is used with a(n) ____.
A) voltmeter
B) clamp-on ammeter
C) ohmmeter
D) megger
A) voltmeter
B) clamp-on ammeter
C) ohmmeter
D) megger
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
16
If line one of a circuit had a potential of 120 V and line two was neutral, the potential voltage (difference) between line one and line two would be zero volts.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
17
A 120-V/24-V control transformer has a VA rating of 20. The maximum amperage the transformer will put out is 0.8 amps.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
18
An electrical power consuming component ____.
A) is normally wired in series in an electrical circuit
B) is normally used to pass power to another component
C) is often a basic switch
D) is also known as a load
A) is normally wired in series in an electrical circuit
B) is normally used to pass power to another component
C) is often a basic switch
D) is also known as a load
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
19
While troubleshooting a 24-V control circuit consisting of a thermostat, a pressure control, and a contactor coil, the technician reads 24 volts across the thermostat, 0 volts across the pressure control, and 0 volts across the contactor coil. The technician makes the following statements. The following statements are all considered to be true.
A) The transformer is burned out.
B) The thermostat is open.
C) The contactor coil is energized.
A) The transformer is burned out.
B) The thermostat is open.
C) The contactor coil is energized.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
20
An example of a power consuming device would be a(n) ____ while an example of a non-power consuming device would be a(n) ____.
A) single-pole single-throw switch, light bulb
B) light bulb, electric motor
C) electric motor, light bulb
D) light bulb, single-pole single-throw switch
A) single-pole single-throw switch, light bulb
B) light bulb, electric motor
C) electric motor, light bulb
D) light bulb, single-pole single-throw switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
21
Non-power-consuming, or power-passing, devices are commonly referred to as ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
22
In a high voltage circuit, is the fan motor a power-passing or power-consuming device?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
23
In a residential air conditioning system, how are the outdoor fan and compressor wired with respect to each other?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
24
What is the amperage capacity of a 240-V/24-V control transformer with a 40 VA rating?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
25
When applying a voltmeter to measure the voltage of a power source, on what range is the meter set?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
26
One way to troubleshoot a(n) ____________________ on a heating and cooling system is to first turn the fan selector switch to the FAN ON position and see if the fan starts.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
27
How is the heat anticipator normally wired to the heating contacts?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
28
Explain how to read very low currents in a control circuit using a clamp-on amp meter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
29
While checking a simple series 115-V circuit containing a fuse, a switch, and a light bulb, the technician's voltmeter reads 115 volts across the light bulb socket. The light bulb is not on. He correctly concludes that the ____________________ is defective.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
30
What three devices are usually found in series with the "Y" terminal of a low voltage control circuit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
31
How is the cooling anticipator normally wired to the cooling contacts?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
32
Without _________________________ voltage, there is no low voltage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck
33
What are the three components that have to operate when a residential air conditioning system is in the cooling mode?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 33 في هذه المجموعة.
فتح الحزمة
k this deck