Deck 38: Installation

ملء الشاشة (f)
exit full mode
سؤال
When hanging a horizontal air handler, it should be pitched toward the drain port for proper condensate removal.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
When the length of quick-connect precharged line sets is altered, the charge will not normally have to be altered.
سؤال
Application of acoustical lining to the interior of a duct is accomplished by using tabs, glue, or both.
سؤال
An auxiliary drain pan under the unit is recommended when the evaporator is installed ____.

A) near a dry well
B) at the end of the house
C) above the conditioned space
D) next to a driveway or patio
سؤال
A boot in a duct system is a fitting used ____.

A) at the plenum
B) between the trunk duct and the branch duct
C) between the branch duct and the supply register
D) to eliminate vibration between the unit and the duct
سؤال
What two fasteners are used with fiberglass ductboard?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
سؤال
When installing a split air-conditioning system with a remote condensing unit, the line set may be altered if the standard length was incorrect for installation.
سؤال
____ used at the end of a metal duct run will help reduce any noise that may be traveling through the duct.

A) Fiberglass ductboard
B) Aluminum duct
C) Insulated metal duct
D) Flexible duct
سؤال
A good way to fasten acoustical lining to the inside of sheet metal duct is to use ____.

A) "S" fasteners (slips) and drive clips
B) staples and tape
C) self-tapping screws and draw bands
D) tabs and adhesives
سؤال
The sun shining on the panels and coils of the condensing section will lower the efficiency of the unit.
سؤال
Once the power has been connected to the condensing unit of a package air conditioner, it is a good idea to start the compressor immediately to make certain it runs.
سؤال
One drawback of using custom made, pre-fabricated duct sections is that ____.

A) if the measuring was not done correctly, the job may not go together
B) altering a duct section at the job site results in lost time
C) altering a duct section at the job site is extremely cost-ineffective
D) All of the above.
سؤال
Power to the control transformer is controlled by the conditioned area thermostat.
سؤال
What fastener is commonly used with round flexible duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws.
D) Tabs and adhesives.
سؤال
After refrigerant lines have been installed, they should be evacuated to a(n) ____ vacuum.

A) average
B) low
C) moderate
D) deep
سؤال
What two fasteners are used with sheet metal square and rectangular duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
سؤال
When removing the rubber plugs from a line set, the hiss indicates that the tubing is not leaking.
سؤال
One purpose of a flexible duct connector in a duct system is to reduce the transmission of noise and vibration.
سؤال
A fitting used to change the size of a square or rectangular duct is called a(n) ____________________.
سؤال
A trap in the condensate line prevents ____.

A) air from being drawn up into unit from the end of the drain
B) foreign particles from being pulled into the condenser
C) the pump turning on if the float fails
D) Both a and b.
سؤال
Before a system is evacuated, all piping should be filled with nitrogen and a small amount of refrigerant, in order to be ___________________ checked.
سؤال
The typical gauge wire that is used in low voltage control circuits is ____________________ gauge.
سؤال
Even though the cooling wire runs from the thermostat to the air handler, it actually just continues on to the condensing unit. Why isn't the cooling wire run directly from the thermostat to the condensing unit?
سؤال
What materials are normally used in air-conditioning duct systems?
سؤال
Explain service accessibility.
سؤال
Why is it necessary that the crankcase heater heats the compressor crankcase before starting the compressor?
سؤال
How much does sunshine affect the operation of a condensing unit?
سؤال
A split central air-conditioning system is installed with the control transformer located in the attic-hung air handler and the condensing unit located outside. The low voltage wire from the thermostat is run to the ____________________.
سؤال
The line voltage for a system is normally installed by whom?
سؤال
What does a technician do before altering a precharged line set?
سؤال
A round to rectangular fitting is called a(n) ____________________.
سؤال
If a duct system has large air leaks at the connections, what can be used to seal them up?
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/32
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 38: Installation
1
When hanging a horizontal air handler, it should be pitched toward the drain port for proper condensate removal.
False
2
When the length of quick-connect precharged line sets is altered, the charge will not normally have to be altered.
False
3
Application of acoustical lining to the interior of a duct is accomplished by using tabs, glue, or both.
True
4
An auxiliary drain pan under the unit is recommended when the evaporator is installed ____.

A) near a dry well
B) at the end of the house
C) above the conditioned space
D) next to a driveway or patio
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
5
A boot in a duct system is a fitting used ____.

A) at the plenum
B) between the trunk duct and the branch duct
C) between the branch duct and the supply register
D) to eliminate vibration between the unit and the duct
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
6
What two fasteners are used with fiberglass ductboard?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
7
When installing a split air-conditioning system with a remote condensing unit, the line set may be altered if the standard length was incorrect for installation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
8
____ used at the end of a metal duct run will help reduce any noise that may be traveling through the duct.

A) Fiberglass ductboard
B) Aluminum duct
C) Insulated metal duct
D) Flexible duct
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
9
A good way to fasten acoustical lining to the inside of sheet metal duct is to use ____.

A) "S" fasteners (slips) and drive clips
B) staples and tape
C) self-tapping screws and draw bands
D) tabs and adhesives
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
10
The sun shining on the panels and coils of the condensing section will lower the efficiency of the unit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
11
Once the power has been connected to the condensing unit of a package air conditioner, it is a good idea to start the compressor immediately to make certain it runs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
12
One drawback of using custom made, pre-fabricated duct sections is that ____.

A) if the measuring was not done correctly, the job may not go together
B) altering a duct section at the job site results in lost time
C) altering a duct section at the job site is extremely cost-ineffective
D) All of the above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
13
Power to the control transformer is controlled by the conditioned area thermostat.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
14
What fastener is commonly used with round flexible duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws.
D) Tabs and adhesives.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
15
After refrigerant lines have been installed, they should be evacuated to a(n) ____ vacuum.

A) average
B) low
C) moderate
D) deep
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
16
What two fasteners are used with sheet metal square and rectangular duct?

A) "S" fasteners (slips) and drive clips.
B) Staples and tape.
C) Self-tapping screws and draw bands.
D) Tabs and adhesives.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
17
When removing the rubber plugs from a line set, the hiss indicates that the tubing is not leaking.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
18
One purpose of a flexible duct connector in a duct system is to reduce the transmission of noise and vibration.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
19
A fitting used to change the size of a square or rectangular duct is called a(n) ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
20
A trap in the condensate line prevents ____.

A) air from being drawn up into unit from the end of the drain
B) foreign particles from being pulled into the condenser
C) the pump turning on if the float fails
D) Both a and b.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
21
Before a system is evacuated, all piping should be filled with nitrogen and a small amount of refrigerant, in order to be ___________________ checked.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
22
The typical gauge wire that is used in low voltage control circuits is ____________________ gauge.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
23
Even though the cooling wire runs from the thermostat to the air handler, it actually just continues on to the condensing unit. Why isn't the cooling wire run directly from the thermostat to the condensing unit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
24
What materials are normally used in air-conditioning duct systems?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
25
Explain service accessibility.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
26
Why is it necessary that the crankcase heater heats the compressor crankcase before starting the compressor?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
27
How much does sunshine affect the operation of a condensing unit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
28
A split central air-conditioning system is installed with the control transformer located in the attic-hung air handler and the condensing unit located outside. The low voltage wire from the thermostat is run to the ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
29
The line voltage for a system is normally installed by whom?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
30
What does a technician do before altering a precharged line set?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
31
A round to rectangular fitting is called a(n) ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
32
If a duct system has large air leaks at the connections, what can be used to seal them up?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 32 في هذه المجموعة.