Deck 9: Strategies of On-Board Diagnostic Continuous Monitors

ملء الشاشة (f)
exit full mode
سؤال
A Type A misfire is a misfire that will cause emission levels to exceed 1.5 times the FTP and will set a code and turn on the MIL on the second consecutive trip where it is detected.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Technician A says the functional test observes the reaction of an output device to a command from the PCM. Technician B says with a scan tool you can access the Readiness Status menu to determine which monitors have run. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
Technician A says the learned LTFT corrections are used as a new base line for STFT. Technician B says the STFT values are constantly adjusted by the PCM to correct for rich/lean running conditions. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
Technician A says that the engine misfire monitor is a non-continuous monitor. Technician B says that the engine misfire monitor is a continuous monitor. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
A Type B misfire is one that could cause immediate damage to the catalytic converter, and the misfire monitor will cause the MIL to flash.
سؤال
Which of the OBD II monitors checks circuit integrity?

A) continuity detection monitor
B) comprehensive component monitor
C) short detection monitor
D) misfire monitor
سؤال
The continuous monitors act as a safety gate against emission system failure that could result in increased pollutants being emitted.
سؤال
Technician A says the comprehensive component monitor will use three-trip logic when determining when to set a DTC and illuminate the MIL. Technician B says an OBD II system requires a drive cycle to occur that meets specific enable criteria before the monitors will run to completion. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
Technician A says the fuel system monitor may not be allowed to run if a pending code is stored. Technician B says the comprehensive component monitor will use one-trip logic when determining when to set a DTC and illuminate the MIL. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
The continuous monitors consist of three separate monitors.
سؤال
Technician A says a random misfire or a multiple cylinder misfire will be recorded as a P0300 code. Technician B says that a MIL that is flashing is an indication of an intermittent emission system failure that is not currently occurring. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
The comprehensive component monitor begins to run shortly after the vehicle is started.
سؤال
Technician A says the comprehensive component monitor continues to run until all sensors have been tested once. Technician B says the rationality test checks to see if the input values from a sensor make sense, based on the current operating conditions at the time the test is performed. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
The PCM closely monitors the fuel delivery system through the use of the fuel monitor.
سؤال
The comprehensive component monitor will use one-trip logic when determining when to set a DTC and illuminate the MIL.
سؤال
Technician A says the continuous component monitor performs operating range testing of emission control sensors. Technician B says the continuous component monitor performs rationality testing of emission control sensors. Who is correct?

A) A only
B) B only
C) both A and B
D) neither a nor B
سؤال
A misfire occurs when the air/fuel mixture in the combustion chamber ignites and complete combustion occurs.
سؤال
As a result of a misfire, unburned hydrocarbons (HC) are exhausted from the combustion chamber into the exhaust system, where they enter the catalytic converter.
سؤال
Technician A says that the catalyst efficiency monitor evaluates the catalyst's ability to store oxygen. Technician B says the comprehensive component monitor looks for circuit shorts and opens. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
سؤال
The continuous monitors are the catalyst efficiency, misfire, and continuous component monitors.
سؤال
When may the fuel system monitor not be allowed to run?
سؤال
Explain what a Type A misfire is and how the PCM reacts to it.
سؤال
What logic does the PCM use to detect a cylinder misfire?
سؤال
Explain what the comprehensive component monitor is.
سؤال
List the three separate monitors that make up the continuous monitors?
سؤال
How can a diagnostic scan tool be used to aid in performing a drive cycle, and what is a typical pattern for an OBD II drive cycle?
سؤال
What do rationality tests check for?
سؤال
What values are constantly adjusted by the PCM to correct for rich/lean running conditions?
سؤال
What type of misfire will cause the misfire monitor to illuminate the MIL steady but not to flash?
سؤال
When does the fuel system monitor run, and what is its role?
سؤال
Explain what Type B and Type C misfires are and what the PCM does to react to these types of misfires.
سؤال
What causes a misfire to occur?
سؤال
What type of logic does the comprehensive component monitor use when determining whether or not to set a DTC and illuminate the MIL?
سؤال
What are the basic causes of a cylinder misfire, and what adverse effect do they have on tailpipe emissions?
سؤال
What must the misfire monitor have the ability to do?
سؤال
What is long-term fuel trim (LTFT)?
سؤال
How does the PCM use short-term fuel trim (STFT) information?
سؤال
What type of tests does the comprehensive component monitor perform, and when does the it run?
سؤال
What type of misfire could cause immediate damage to the catalytic converter and will cause the MIL to flash?
سؤال
When does the comprehensive component monitor run?
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/40
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 9: Strategies of On-Board Diagnostic Continuous Monitors
1
A Type A misfire is a misfire that will cause emission levels to exceed 1.5 times the FTP and will set a code and turn on the MIL on the second consecutive trip where it is detected.
False
2
Technician A says the functional test observes the reaction of an output device to a command from the PCM. Technician B says with a scan tool you can access the Readiness Status menu to determine which monitors have run. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
C
3
Technician A says the learned LTFT corrections are used as a new base line for STFT. Technician B says the STFT values are constantly adjusted by the PCM to correct for rich/lean running conditions. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
C
4
Technician A says that the engine misfire monitor is a non-continuous monitor. Technician B says that the engine misfire monitor is a continuous monitor. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
5
A Type B misfire is one that could cause immediate damage to the catalytic converter, and the misfire monitor will cause the MIL to flash.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
6
Which of the OBD II monitors checks circuit integrity?

A) continuity detection monitor
B) comprehensive component monitor
C) short detection monitor
D) misfire monitor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
7
The continuous monitors act as a safety gate against emission system failure that could result in increased pollutants being emitted.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
8
Technician A says the comprehensive component monitor will use three-trip logic when determining when to set a DTC and illuminate the MIL. Technician B says an OBD II system requires a drive cycle to occur that meets specific enable criteria before the monitors will run to completion. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
9
Technician A says the fuel system monitor may not be allowed to run if a pending code is stored. Technician B says the comprehensive component monitor will use one-trip logic when determining when to set a DTC and illuminate the MIL. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
10
The continuous monitors consist of three separate monitors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
11
Technician A says a random misfire or a multiple cylinder misfire will be recorded as a P0300 code. Technician B says that a MIL that is flashing is an indication of an intermittent emission system failure that is not currently occurring. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
12
The comprehensive component monitor begins to run shortly after the vehicle is started.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
13
Technician A says the comprehensive component monitor continues to run until all sensors have been tested once. Technician B says the rationality test checks to see if the input values from a sensor make sense, based on the current operating conditions at the time the test is performed. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
14
The PCM closely monitors the fuel delivery system through the use of the fuel monitor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
15
The comprehensive component monitor will use one-trip logic when determining when to set a DTC and illuminate the MIL.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
16
Technician A says the continuous component monitor performs operating range testing of emission control sensors. Technician B says the continuous component monitor performs rationality testing of emission control sensors. Who is correct?

A) A only
B) B only
C) both A and B
D) neither a nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
17
A misfire occurs when the air/fuel mixture in the combustion chamber ignites and complete combustion occurs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
18
As a result of a misfire, unburned hydrocarbons (HC) are exhausted from the combustion chamber into the exhaust system, where they enter the catalytic converter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
19
Technician A says that the catalyst efficiency monitor evaluates the catalyst's ability to store oxygen. Technician B says the comprehensive component monitor looks for circuit shorts and opens. Who is correct?

A) A only
B) B only
C) both A and B
D) neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
20
The continuous monitors are the catalyst efficiency, misfire, and continuous component monitors.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
21
When may the fuel system monitor not be allowed to run?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
22
Explain what a Type A misfire is and how the PCM reacts to it.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
23
What logic does the PCM use to detect a cylinder misfire?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
24
Explain what the comprehensive component monitor is.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
25
List the three separate monitors that make up the continuous monitors?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
26
How can a diagnostic scan tool be used to aid in performing a drive cycle, and what is a typical pattern for an OBD II drive cycle?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
27
What do rationality tests check for?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
28
What values are constantly adjusted by the PCM to correct for rich/lean running conditions?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
29
What type of misfire will cause the misfire monitor to illuminate the MIL steady but not to flash?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
30
When does the fuel system monitor run, and what is its role?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
31
Explain what Type B and Type C misfires are and what the PCM does to react to these types of misfires.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
32
What causes a misfire to occur?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
33
What type of logic does the comprehensive component monitor use when determining whether or not to set a DTC and illuminate the MIL?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
34
What are the basic causes of a cylinder misfire, and what adverse effect do they have on tailpipe emissions?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
35
What must the misfire monitor have the ability to do?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
36
What is long-term fuel trim (LTFT)?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
37
How does the PCM use short-term fuel trim (STFT) information?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
38
What type of tests does the comprehensive component monitor perform, and when does the it run?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
39
What type of misfire could cause immediate damage to the catalytic converter and will cause the MIL to flash?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
40
When does the comprehensive component monitor run?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 40 في هذه المجموعة.