A detached garage supplied with electrical power must always have at least one 125-volt, 15- or 20-amp receptacle and at least one wall switch-controlled lighting outlet.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Incandescent lamps used for lighting in a garage can be replaced with compact fluorescent (CFL) lamps or LED lamps.
سؤال
Good wiring practices require electricians to install at least __________ lighting outlets in a two-car garage to provide adequate lighting.

A) 1
B) 2
C) 3
D) 4
سؤال
All 15- and 20-amp, 125- and 250-volt non-locking receptacles used outdoors must be listed as weather-resistant.
سؤال
An overhead garage door is not considered an entrance or exit by the NEC and therefore does not require a lighting outlet(s) to be installed over or next to it.
سؤال
According to the NEC, which of the following 125 volt, 15 or 20 amp duplex receptacles installed in a garage to serve cord-and-plug appliances such as a refrigerator or freezer, requires GFCI protection?

A) Duplex receptacles located beside the appliance
B) Duplex receptacles located behind the appliance
C) Duplex receptacles located on the wall and just above the appliance
D) All of the above
سؤال
When used as an interior wiring method, Type UF cable must be installed according to the same rules as Type NM cable.
سؤال
Section 210.17 requires any outlet that is installed in a garage for the purpose of charging an electric vehicle to be supplied by a separate branch circuit and the branch circuit cannot have any other outlets on it.
سؤال
PVC conduit is not permitted as the only means of support for a junction box used with underwater lighting when wiring permanently installed swimming pools.
سؤال
If two ground rods are installed at a detached garage they must be located at least 12 feet (1.8 m) apart.
سؤال
Overhead conductor spans are permitted to be supported by trees.
سؤال
Section 210.52(G)(1) requires that at least two receptacle outlets be installed for each car space in a garage.
سؤال
In attached garages, the NEC requires at least __________.

A) one single 125-volt receptacle
B) one duplex 125-volt receptacle
C) one wall switch-controlled lighting outlet
D) one 125-volt, 15 or 20 amp receptacle and one wall switch-controlled lighting outlet
سؤال
If the feeder supplying power to a detached garage is installed with an equipment grounding conductor, the NEC does not require a separate grounding electrode system to be established at the detached garage.
سؤال
Any 15 or 20 amp, 125 through 250 volt receptacle installed in a wet location must have a cover or enclosure that keeps it weatherproof, but only when there isn't anything plugged into it.
سؤال
If you are required to install wiring for a storage shed or other accessory building, install the wiring the same as for a detached garage.
سؤال
The maximum distance between receptacles in a garage is __________ feet.

A) 4
B) 6
C) 12
D) there is no NEC requirement
سؤال
A GFCI receptacle is an acceptable means to provide the required GFCI protection to a hydromassage bathtub.
سؤال
When running branch circuit wiring in a raceway from an electrical panel inside the house to pool associated motors, an insulated equipment grounding conductor __________.

A) must be run
B) may be run
C) shall not be run
D) depends if the raceway is metallic or nonmetallic
سؤال
Outdoor lighting can be mounted on trees.
سؤال
The NEC requires that if a feeder supplying a detached garage from the service in the main house has an equipment grounding conductor run with the feeder, the grounded conductor __________ be connected to the equipment grounding conductor or to the grounding electrode system in the garage.

A) may
B) shall
C) shall not
D) could
سؤال
A permanently installed swimming pool must have at least one 125-volt, 15- or 20-amp receptacle located a minimum of __________ feet from the inside wall of the pool.

A) 3
B) 5
C) 6
D) 10
سؤال
Type UF cable can be used outdoors in direct exposure to the sun only if __________.

A) it is listed as being sunlight resistant
B) it has a sunlight resistant marking on the cable sheathing
C) it is rated for less than 300 volts
D) both A and B
سؤال
Locations subject to saturation with water or other liquids in unprotected areas exposed to the weather are called ____________________ locations.
سؤال
The conductors that provide power to pool lighting fixtures must be GFCI protected if the voltage is above __________ volts.

A) 15
B) 24
C) 120
D) 240
سؤال
The minimum burial depth for type UF cable can be found in Table __________ of the NEC.

A) 110.26
B) 220.12
C) 300.5
D) 310.15(B)(16)
سؤال
The most important installation practice for a permanently installed swimming pool is the proper grounding and bonding together of all ____________________ parts in and around the pool.
سؤال
According to the NEC, the minimum burial depth for a direct buried cable like Type UF is __________ inches. (General Rule)

A) 6
B) 12
C) 18
D) 24
سؤال
Lighting fixture assemblies for storage pools are permitted as long as the lamp operates at no more than __________ volts.

A) 15
B) 24
C) 120
D) 240
سؤال
Pool motors can be cord and plug connected but if they are, the cord can't be more than __________ feet long and must contain an equipment grounding conductor sized according to Table 250.122.

A) 1
B) 2
C) 3
D) 4
سؤال
Without a special ballast, fluorescent lamps installed in a garage usually will not start when exposed to temperatures below __________ degrees F.

A) 60
B) 50
C) 70
D) 80
سؤال
If a cable is buried underground to bring power to a detached garage, Type ____________________ cable is typically used.
سؤال
In an outdoor pool area, the NEC requires luminaires, ceiling suspended paddle fans, or lighting outlets not to be installed over the pool or an area extending __________ feet horizontally from the inside wall of the pool.

A) 5
B) 10
C) 12
D) 20
سؤال
For spas and hot tubs, at least one 125-volt, 15- or 20-ampere rated receptacle must be installed at least __________ from the inside wall of the spa or hot tub.

A) 3
B) 5
C) 6
D) 10
سؤال
For a permanently installed swimming pool, any 15 or 20 amp, 125 through 250 volt rated receptacle located within __________ feet of a pool's inside wall must be GFCI protected.

A) 3
B) 10
C) 12
D) 20
سؤال
When bonding the various metal parts of a permanently installed swimming pool, all bonding wires must be solid copper and be ____ AWG or larger.

A) 10
B) 8
C) 6
D) 4
سؤال
Article __________ in the NEC covers the requirements for swimming pools, hot tubs, and hydromassage tubs.

A) 110
B) 250
C) 440
D) 680
سؤال
A light-sensing device used to control lighting fixtures in response to detected light levels is called a _________.

A) transfer switch
B) no-niche luminaire
C) dry-niche luminaire
D) photocell
سؤال
Assuming a 20 amp circuit breaker and GFCI protection, the minimum burial depth for a Type UF cable running to a 120 volt pole light at a residence is __________ inches.

A) 6
B) 12
C) 18
D) 24
سؤال
A welding process for joining materials that employs molten metal to permanently join the conductors together is called __________ welding.

A) stick
B) thermal
C) exothermic
D) cohesive
سؤال
A circuit rated at 6600 watts and 240 volts will draw ____________________ amperes.
سؤال
Name the two basic types of residential generators that can be used in a standby power system.
سؤال
If a lighting fixture is installed under a canopy or under an open porch, it is considered to be in a(n) ____________________ location.
سؤال
If a conductor or cable has a(n) ____________________ in their insulation designation, such as THWN, it means that it is suitable for installation in a wet location.
سؤال
Explain why a 14 AWG Type NM cable is not permitted to be used for a spa or hot tub.
سؤال
Describe a multiwire branch circuit.
سؤال
Receptacle outlets located outdoors that are fed using an underground wiring method and supported by conduit must have at least ____________________ conduit(s) threaded wrenchtight into the box.
سؤال
Explain the benefits of the new generator-ready loadcenters.
سؤال
A(n) ____________________ switch eliminates the possibility of a generator voltage being applied to the secondary of the utility's supply transformer.
سؤال
A(n) ____________________ is a rotating machine used to convert mechanical energy into electrical energy.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/50
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 15: Special Residential Wiring Situations
1
A detached garage supplied with electrical power must always have at least one 125-volt, 15- or 20-amp receptacle and at least one wall switch-controlled lighting outlet.
True
2
Incandescent lamps used for lighting in a garage can be replaced with compact fluorescent (CFL) lamps or LED lamps.
True
3
Good wiring practices require electricians to install at least __________ lighting outlets in a two-car garage to provide adequate lighting.

A) 1
B) 2
C) 3
D) 4
C
4
All 15- and 20-amp, 125- and 250-volt non-locking receptacles used outdoors must be listed as weather-resistant.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
5
An overhead garage door is not considered an entrance or exit by the NEC and therefore does not require a lighting outlet(s) to be installed over or next to it.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
6
According to the NEC, which of the following 125 volt, 15 or 20 amp duplex receptacles installed in a garage to serve cord-and-plug appliances such as a refrigerator or freezer, requires GFCI protection?

A) Duplex receptacles located beside the appliance
B) Duplex receptacles located behind the appliance
C) Duplex receptacles located on the wall and just above the appliance
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
7
When used as an interior wiring method, Type UF cable must be installed according to the same rules as Type NM cable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
8
Section 210.17 requires any outlet that is installed in a garage for the purpose of charging an electric vehicle to be supplied by a separate branch circuit and the branch circuit cannot have any other outlets on it.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
9
PVC conduit is not permitted as the only means of support for a junction box used with underwater lighting when wiring permanently installed swimming pools.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
10
If two ground rods are installed at a detached garage they must be located at least 12 feet (1.8 m) apart.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
11
Overhead conductor spans are permitted to be supported by trees.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
12
Section 210.52(G)(1) requires that at least two receptacle outlets be installed for each car space in a garage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
13
In attached garages, the NEC requires at least __________.

A) one single 125-volt receptacle
B) one duplex 125-volt receptacle
C) one wall switch-controlled lighting outlet
D) one 125-volt, 15 or 20 amp receptacle and one wall switch-controlled lighting outlet
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
14
If the feeder supplying power to a detached garage is installed with an equipment grounding conductor, the NEC does not require a separate grounding electrode system to be established at the detached garage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
15
Any 15 or 20 amp, 125 through 250 volt receptacle installed in a wet location must have a cover or enclosure that keeps it weatherproof, but only when there isn't anything plugged into it.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
16
If you are required to install wiring for a storage shed or other accessory building, install the wiring the same as for a detached garage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
17
The maximum distance between receptacles in a garage is __________ feet.

A) 4
B) 6
C) 12
D) there is no NEC requirement
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
18
A GFCI receptacle is an acceptable means to provide the required GFCI protection to a hydromassage bathtub.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
19
When running branch circuit wiring in a raceway from an electrical panel inside the house to pool associated motors, an insulated equipment grounding conductor __________.

A) must be run
B) may be run
C) shall not be run
D) depends if the raceway is metallic or nonmetallic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
20
Outdoor lighting can be mounted on trees.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
21
The NEC requires that if a feeder supplying a detached garage from the service in the main house has an equipment grounding conductor run with the feeder, the grounded conductor __________ be connected to the equipment grounding conductor or to the grounding electrode system in the garage.

A) may
B) shall
C) shall not
D) could
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
22
A permanently installed swimming pool must have at least one 125-volt, 15- or 20-amp receptacle located a minimum of __________ feet from the inside wall of the pool.

A) 3
B) 5
C) 6
D) 10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
23
Type UF cable can be used outdoors in direct exposure to the sun only if __________.

A) it is listed as being sunlight resistant
B) it has a sunlight resistant marking on the cable sheathing
C) it is rated for less than 300 volts
D) both A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
24
Locations subject to saturation with water or other liquids in unprotected areas exposed to the weather are called ____________________ locations.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
25
The conductors that provide power to pool lighting fixtures must be GFCI protected if the voltage is above __________ volts.

A) 15
B) 24
C) 120
D) 240
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
26
The minimum burial depth for type UF cable can be found in Table __________ of the NEC.

A) 110.26
B) 220.12
C) 300.5
D) 310.15(B)(16)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
27
The most important installation practice for a permanently installed swimming pool is the proper grounding and bonding together of all ____________________ parts in and around the pool.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
28
According to the NEC, the minimum burial depth for a direct buried cable like Type UF is __________ inches. (General Rule)

A) 6
B) 12
C) 18
D) 24
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
29
Lighting fixture assemblies for storage pools are permitted as long as the lamp operates at no more than __________ volts.

A) 15
B) 24
C) 120
D) 240
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
30
Pool motors can be cord and plug connected but if they are, the cord can't be more than __________ feet long and must contain an equipment grounding conductor sized according to Table 250.122.

A) 1
B) 2
C) 3
D) 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
31
Without a special ballast, fluorescent lamps installed in a garage usually will not start when exposed to temperatures below __________ degrees F.

A) 60
B) 50
C) 70
D) 80
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
32
If a cable is buried underground to bring power to a detached garage, Type ____________________ cable is typically used.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
33
In an outdoor pool area, the NEC requires luminaires, ceiling suspended paddle fans, or lighting outlets not to be installed over the pool or an area extending __________ feet horizontally from the inside wall of the pool.

A) 5
B) 10
C) 12
D) 20
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
34
For spas and hot tubs, at least one 125-volt, 15- or 20-ampere rated receptacle must be installed at least __________ from the inside wall of the spa or hot tub.

A) 3
B) 5
C) 6
D) 10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
35
For a permanently installed swimming pool, any 15 or 20 amp, 125 through 250 volt rated receptacle located within __________ feet of a pool's inside wall must be GFCI protected.

A) 3
B) 10
C) 12
D) 20
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
36
When bonding the various metal parts of a permanently installed swimming pool, all bonding wires must be solid copper and be ____ AWG or larger.

A) 10
B) 8
C) 6
D) 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
37
Article __________ in the NEC covers the requirements for swimming pools, hot tubs, and hydromassage tubs.

A) 110
B) 250
C) 440
D) 680
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
38
A light-sensing device used to control lighting fixtures in response to detected light levels is called a _________.

A) transfer switch
B) no-niche luminaire
C) dry-niche luminaire
D) photocell
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
39
Assuming a 20 amp circuit breaker and GFCI protection, the minimum burial depth for a Type UF cable running to a 120 volt pole light at a residence is __________ inches.

A) 6
B) 12
C) 18
D) 24
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
40
A welding process for joining materials that employs molten metal to permanently join the conductors together is called __________ welding.

A) stick
B) thermal
C) exothermic
D) cohesive
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
41
A circuit rated at 6600 watts and 240 volts will draw ____________________ amperes.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
42
Name the two basic types of residential generators that can be used in a standby power system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
43
If a lighting fixture is installed under a canopy or under an open porch, it is considered to be in a(n) ____________________ location.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
44
If a conductor or cable has a(n) ____________________ in their insulation designation, such as THWN, it means that it is suitable for installation in a wet location.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
45
Explain why a 14 AWG Type NM cable is not permitted to be used for a spa or hot tub.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
46
Describe a multiwire branch circuit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
47
Receptacle outlets located outdoors that are fed using an underground wiring method and supported by conduit must have at least ____________________ conduit(s) threaded wrenchtight into the box.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
48
Explain the benefits of the new generator-ready loadcenters.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
49
A(n) ____________________ switch eliminates the possibility of a generator voltage being applied to the secondary of the utility's supply transformer.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
50
A(n) ____________________ is a rotating machine used to convert mechanical energy into electrical energy.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.