Deck 10: Tower

ملء الشاشة (f)
exit full mode
سؤال
Impact grade sockets should always be used with power bolting tools.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Utility size wind turbine tower designs have generally been self-supporting lattice or tube.
سؤال
Components listed on a tower inspection and maintenance checklist may include: cables, mounting hardware, ladder safety equipment, and ___________.

A) tower lighting
B) GFCI receptacles
C) access hatches
D) All answers are correct
سؤال
An acceptable sequence for tightening fasteners around a circle is called a __________.

A) star pattern
B) moon pattern
C) cross pattern
D) None of the answers are correct
سؤال
Accidents involving power bolting tools may include: crush, pinch, and _______.

A) injection
B) amputation
C) burns
D) All answers are correct
سؤال
All cables running up the tower are used for electrical power transfer to the utility interconnection.
سؤال
Drip loop refers to the accumulation of cable located immediately above the yaw deck.
سؤال
Typical ladder safety systems include a vertical life line cable assembly and ________.

A) bungee cord
B) rail system
C) number ten noodle
D) All answers are correct
سؤال
Thermal imaging of cable bundles during operation or immediately after shut down would be a good means to determine a cable splice or termination problem.
سؤال
Contamination of the power cable insulating jacket with lubricating oil will never cause damage to the cable.
سؤال
Inspection of the ladder assembly, decks, and access hatches is not necessary during any maintenance activity.
سؤال
Bolts retaining the tube tower sections should be inspected for torque level every semi-annual preventative maintenance cycle.
سؤال
Inspection items for cables may include: nicks, abrassion, and _________.

A) oil contamination
B) cuts
C) missing insulation
D) All answers are correct
سؤال
An inspection of cable bundles running up the tower assembly should always include: mounting hardware, insulation damage, and weight.
سؤال
Using a paint pen to mark the final position of a nut after a torque inspection is a good means to determine if the nut loosens between maintenance cycles.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 10: Tower
1
Impact grade sockets should always be used with power bolting tools.
True
2
Utility size wind turbine tower designs have generally been self-supporting lattice or tube.
True
3
Components listed on a tower inspection and maintenance checklist may include: cables, mounting hardware, ladder safety equipment, and ___________.

A) tower lighting
B) GFCI receptacles
C) access hatches
D) All answers are correct
D
4
An acceptable sequence for tightening fasteners around a circle is called a __________.

A) star pattern
B) moon pattern
C) cross pattern
D) None of the answers are correct
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
Accidents involving power bolting tools may include: crush, pinch, and _______.

A) injection
B) amputation
C) burns
D) All answers are correct
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
All cables running up the tower are used for electrical power transfer to the utility interconnection.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
Drip loop refers to the accumulation of cable located immediately above the yaw deck.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
Typical ladder safety systems include a vertical life line cable assembly and ________.

A) bungee cord
B) rail system
C) number ten noodle
D) All answers are correct
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
Thermal imaging of cable bundles during operation or immediately after shut down would be a good means to determine a cable splice or termination problem.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
Contamination of the power cable insulating jacket with lubricating oil will never cause damage to the cable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Inspection of the ladder assembly, decks, and access hatches is not necessary during any maintenance activity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
Bolts retaining the tube tower sections should be inspected for torque level every semi-annual preventative maintenance cycle.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
Inspection items for cables may include: nicks, abrassion, and _________.

A) oil contamination
B) cuts
C) missing insulation
D) All answers are correct
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
An inspection of cable bundles running up the tower assembly should always include: mounting hardware, insulation damage, and weight.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
Using a paint pen to mark the final position of a nut after a torque inspection is a good means to determine if the nut loosens between maintenance cycles.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.