Deck 18: Steam Heat

ملء الشاشة (f)
exit full mode
سؤال
_________________________ direct return systems often use balancing valves to evenly distribute water flow through each branch.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Steam is circulated through the system as a vapor to the steam terminal unit, where it is condensed to liquid and returned to the boiler.
سؤال
A ________________________________________ is located at the water level to prevent the boiler from overheating.
سؤال
The ______________________________ and pressure gauge are installed with a connector between them that prevents raw steam from reaching the indicator mechanism, which is a Bourdon tube.
سؤال
______________________________ pumping systems use circulators in both the primary and secondary loops.
سؤال
A _________________________ should be provided with each steam boiler so that the technician can see the boiler water level at a glance.
سؤال
Gas- and oil -fired steam boilers are much like hot water boilers.
سؤال
______________________________ units receive steam vapor and condense it while adding heat to something, usually the conditioned space.
سؤال
_________________________ valves prevent gravity flow through hot water loops when the circulators are off.
سؤال
Steam heat is similar to hot-water heat, except the latent heat of the steam vapor contains a larger amount of heat.
سؤال
Water level is not critical in a steam boiler because the heat-exchange surface is just below the operating water level.
سؤال
The _________________________ line is larger than the liquid condensate return line.
سؤال
System pressure differences in a steam system will cause the water level in a boiler to fluctuate up and down without a special piping arrangement called a _________________________.
سؤال
_________________________ systems utilize monoflo or diverter tees to balance water flow.
سؤال
_________________________ are used to control water flow to different zones in the structure in order to maintain different temperatures in those areas.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 18: Steam Heat
1
_________________________ direct return systems often use balancing valves to evenly distribute water flow through each branch.
Two-pipe
2
Steam is circulated through the system as a vapor to the steam terminal unit, where it is condensed to liquid and returned to the boiler.
True
3
A ________________________________________ is located at the water level to prevent the boiler from overheating.
low-water fuel cutoff control
4
The ______________________________ and pressure gauge are installed with a connector between them that prevents raw steam from reaching the indicator mechanism, which is a Bourdon tube.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
______________________________ pumping systems use circulators in both the primary and secondary loops.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
A _________________________ should be provided with each steam boiler so that the technician can see the boiler water level at a glance.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
Gas- and oil -fired steam boilers are much like hot water boilers.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
______________________________ units receive steam vapor and condense it while adding heat to something, usually the conditioned space.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
_________________________ valves prevent gravity flow through hot water loops when the circulators are off.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
Steam heat is similar to hot-water heat, except the latent heat of the steam vapor contains a larger amount of heat.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Water level is not critical in a steam boiler because the heat-exchange surface is just below the operating water level.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
The _________________________ line is larger than the liquid condensate return line.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
System pressure differences in a steam system will cause the water level in a boiler to fluctuate up and down without a special piping arrangement called a _________________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
_________________________ systems utilize monoflo or diverter tees to balance water flow.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
_________________________ are used to control water flow to different zones in the structure in order to maintain different temperatures in those areas.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.