Deck 9: Gas Piping, Venting, and Appliance Efficiency

ملء الشاشة (f)
exit full mode
سؤال
If there is too much primary air, the gas flame can ____.

A) get blown out
B) "lift" off the burner rack
C) make noise
D) both b and c
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
What is the difference between a yellow gas flame and an orange gas flame?
سؤال
When a gas furnace ignites and is under "full-fire," why does the fan not come on immediately?
سؤال
In a conventional gas furnace, the hot flue gases are ____.

A) forced out a PVC vent with a blower
B) recycled through a secondary heat exchanger and then vented through a draft diverter
C) forced through a type B vent by a blower
D) vented by natural convection
سؤال
Why do propane and butane gas furnaces require 100% shut off in the event of pilot outage?
سؤال
The flame in a gas fired furnace is burning with heavy yellow tips. What is the problem?
سؤال
Match between columns
blower located above heat exchanger
low boy
blower located above heat exchanger
upflow
blower located above heat exchanger
horizontal
blower located above heat exchanger
downflow
سؤال
Match between columns
primarily used in crawl spaces
low boy
primarily used in crawl spaces
upflow
primarily used in crawl spaces
horizontal
primarily used in crawl spaces
downflow
سؤال
Match between columns
blower located below heat exchanger
low boy
blower located below heat exchanger
upflow
blower located below heat exchanger
horizontal
blower located below heat exchanger
downflow
سؤال
Match between columns
return and supply ducts are both on top
low boy
return and supply ducts are both on top
upflow
return and supply ducts are both on top
horizontal
return and supply ducts are both on top
downflow
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 9: Gas Piping, Venting, and Appliance Efficiency
1
If there is too much primary air, the gas flame can ____.

A) get blown out
B) "lift" off the burner rack
C) make noise
D) both b and c
D
2
What is the difference between a yellow gas flame and an orange gas flame?
A yellow flame represents an air-starved flame-carbon monoxide is being produced! An orange flame represents the burning of dust-not dangerous.
3
When a gas furnace ignites and is under "full-fire," why does the fan not come on immediately?
The chamber must warm up first or the blower will circulate cold air.
4
In a conventional gas furnace, the hot flue gases are ____.

A) forced out a PVC vent with a blower
B) recycled through a secondary heat exchanger and then vented through a draft diverter
C) forced through a type B vent by a blower
D) vented by natural convection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
Why do propane and butane gas furnaces require 100% shut off in the event of pilot outage?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
The flame in a gas fired furnace is burning with heavy yellow tips. What is the problem?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
Match between columns
blower located above heat exchanger
low boy
blower located above heat exchanger
upflow
blower located above heat exchanger
horizontal
blower located above heat exchanger
downflow
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
Match between columns
primarily used in crawl spaces
low boy
primarily used in crawl spaces
upflow
primarily used in crawl spaces
horizontal
primarily used in crawl spaces
downflow
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
Match between columns
blower located below heat exchanger
low boy
blower located below heat exchanger
upflow
blower located below heat exchanger
horizontal
blower located below heat exchanger
downflow
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
Match between columns
return and supply ducts are both on top
low boy
return and supply ducts are both on top
upflow
return and supply ducts are both on top
horizontal
return and supply ducts are both on top
downflow
فتح الحزمة