Deck 11: Control of Scatter Radiation

ملء الشاشة (f)
exit full mode
سؤال
The use of a compression device will increase __________.

A) film fog
B) patient dose
C) contrast
D) scatter
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Federal regulations passed in _____ required that positive beam limiting devices be on all manufactured x-ray collimators.

A) 1954
B) 1974
C) 1994
D) 2000
سؤال
The most commonly used beam restricting device is the ____________.

A) extension cone
B) variable collimator
C) aperture diaphragm
D) compression device
سؤال
The use of __________ improves contrast and reduces patient dose.

A) collimation
B) high kVp
C) low kVp
D) less filtration
سؤال
The positive beam limiting device (PBL) assures that the x-ray beam is collimated to __________________.

A) the exact part size
B) 1 cm inside image receptor size
C) the image receptor size
D) 1 cm outside image receptor size
سؤال
The three primary factors influencing the intensity of scatter in the image-forming beam are ___________________.

A) mAs, kVp, and collimation
B) mAs, filtration, and grids
C) kVp, field size, and patient thickness
D) filtration, patient thickness, and mAs
سؤال
Contrast resolution is improved by _____________.

A) tight collimation
B) lowering kVp
C) patient compression
D) All of the above
سؤال
The x-ray interaction that contributes to the clear parts of the image is _____________.

A) coherent scatter
B) Compton interaction
C) photoelectric interaction
D) pair production
سؤال
How can you improve image contrast with a heavy patient without increasing patient dose?

A) Lower kVp and raise mAs.
B) Use tight collimation.
C) Raise kVp and lower mAs.
D) Do both A and B.
سؤال
The x-rays that are transmitted through the patient without interaction contribute to ______________.

A) useful information
B) film fog
C) image noise
D) All of the above
سؤال
Approximately _______% of the x-ray beam incident on the patient is transmitted through the patient without interaction to become part of the image-forming beam.

A) 90-99
B) 80-89
C) 20-29
D) 1
سؤال
A fixed aperture diaphragm should leave a _____ cm unexposed border on the film.

A) 0.1
B) 0.5
C) 1
D) 2
سؤال
Compton scatter contributes to _____________.

A) useful information
B) image noise
C) image contrast
D) All of the above
سؤال
Which kVp selection would result in the most scattered x-rays in the image-forming beam?

A) 90 kVp
B) 75 kVp
C) 60 kVp
D) 50 kVp
سؤال
Lowering kVp ________ patient dose and _________ image contrast.

A) lowers, decreases
B) increases, decreases
C) lowers, increases
D) increases, increases
سؤال
Image-forming x-rays include those which have been _________________.

A) transmitted without interaction
B) scattered through Compton interaction
C) absorbed through photoelectric interaction
D) Both A and B
سؤال
Decreasing the kVp will increase ___________.

A) patient dose
B) image noise
C) Compton scatter
D) optical density
سؤال
Photoelectric interactions increase when ___________ is decreased.

A) mAs
B) patient thickness
C) filtration
D) kVp
سؤال
Beam restriction with a(n) ____________ is only accurate at a fixed SID.

A) aperture diaphragm
B) cone
C) collimator
D) PBL device
سؤال
Scatter radiation increases as ___________________ increases.

A) photoelectric absorption
B) field size
C) filtration
D) contrast
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 11: Control of Scatter Radiation
1
The use of a compression device will increase __________.

A) film fog
B) patient dose
C) contrast
D) scatter
contrast
2
Federal regulations passed in _____ required that positive beam limiting devices be on all manufactured x-ray collimators.

A) 1954
B) 1974
C) 1994
D) 2000
1974
3
The most commonly used beam restricting device is the ____________.

A) extension cone
B) variable collimator
C) aperture diaphragm
D) compression device
variable collimator
4
The use of __________ improves contrast and reduces patient dose.

A) collimation
B) high kVp
C) low kVp
D) less filtration
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
5
The positive beam limiting device (PBL) assures that the x-ray beam is collimated to __________________.

A) the exact part size
B) 1 cm inside image receptor size
C) the image receptor size
D) 1 cm outside image receptor size
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
6
The three primary factors influencing the intensity of scatter in the image-forming beam are ___________________.

A) mAs, kVp, and collimation
B) mAs, filtration, and grids
C) kVp, field size, and patient thickness
D) filtration, patient thickness, and mAs
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
7
Contrast resolution is improved by _____________.

A) tight collimation
B) lowering kVp
C) patient compression
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
8
The x-ray interaction that contributes to the clear parts of the image is _____________.

A) coherent scatter
B) Compton interaction
C) photoelectric interaction
D) pair production
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
9
How can you improve image contrast with a heavy patient without increasing patient dose?

A) Lower kVp and raise mAs.
B) Use tight collimation.
C) Raise kVp and lower mAs.
D) Do both A and B.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
10
The x-rays that are transmitted through the patient without interaction contribute to ______________.

A) useful information
B) film fog
C) image noise
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
11
Approximately _______% of the x-ray beam incident on the patient is transmitted through the patient without interaction to become part of the image-forming beam.

A) 90-99
B) 80-89
C) 20-29
D) 1
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
12
A fixed aperture diaphragm should leave a _____ cm unexposed border on the film.

A) 0.1
B) 0.5
C) 1
D) 2
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
13
Compton scatter contributes to _____________.

A) useful information
B) image noise
C) image contrast
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
14
Which kVp selection would result in the most scattered x-rays in the image-forming beam?

A) 90 kVp
B) 75 kVp
C) 60 kVp
D) 50 kVp
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
15
Lowering kVp ________ patient dose and _________ image contrast.

A) lowers, decreases
B) increases, decreases
C) lowers, increases
D) increases, increases
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
16
Image-forming x-rays include those which have been _________________.

A) transmitted without interaction
B) scattered through Compton interaction
C) absorbed through photoelectric interaction
D) Both A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
17
Decreasing the kVp will increase ___________.

A) patient dose
B) image noise
C) Compton scatter
D) optical density
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
18
Photoelectric interactions increase when ___________ is decreased.

A) mAs
B) patient thickness
C) filtration
D) kVp
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
19
Beam restriction with a(n) ____________ is only accurate at a fixed SID.

A) aperture diaphragm
B) cone
C) collimator
D) PBL device
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
20
Scatter radiation increases as ___________________ increases.

A) photoelectric absorption
B) field size
C) filtration
D) contrast
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.