Deck 4: Oscilloscopes and Dsos

ملء الشاشة (f)
exit full mode
سؤال
A signal showing the voltage of a battery displayed on an analog oscilloscope is being discussed. Technician A says that the display will show one horizontal line above the zero line. Technician B says that the display will show a line sloping upward from zero to the battery voltage level. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A TP sensor signal voltage is being observed using a digital storage oscilloscope. The pattern on the scope occasionally rises to the source voltage level. What does this indicate?

A) Normal operation
B) A momentary short in the TP sensor
C) A momentary open circuit
D) A fault with the scope leads
سؤال
Two technicians are discussing pulse train signals. Technician A says that a pulse train is a DC signal waveform that goes above and below zero volts. Technician B says that a pulse train is a DC voltage that turns on and off in a series of pulses and they do not go below zero. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
سؤال
Which type of oscilloscope displays all voltages without taking samples?

A) Complex
B) Analog
C) Digital
D) None of these
سؤال
Technician A says that analog scopes use an LCD display. Technician B says that digital scopes may use a CRT display. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
سؤال
A digital storage oscilloscope is set to begin displaying a waveform when a certain voltage is detected. This minimum voltage is called ________.

A) threshold
B) trigger
C) trip
D) None of these
سؤال
A typical DSO display screen is arranged in an ________ grid.

A) 6 × 8
B) 8 × 10
C) 8 × 8
D) None of these
سؤال
Technician A says that voltage is usually indicated on the horizontal display axis. Technician B says that time is usually indicated on the horizontal display axis. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
سؤال
________ the time base setting reduces the number of samples per second.

A) Increasing
B) Dividing
C) Decreasing
D) None of these
سؤال
A time base setting of 1ms/div will show a total time of ________ on the scope display

A) 100 ms
B) 1 ms
C) 10 ms
D) None of these
سؤال
Which is the correct voltage division setting for testing a throttle position sensor?

A) 1V
B) 3V
C) 5V
D) 10V
سؤال
Which of these is measured as a percentage?

A) Pulse width
B) Duty cycle
C) Dwell
D) None of these
سؤال
Which of these terms is a measure of the actual on-time measured in milliseconds?

A) Period
B) Pulse width
C) Frequency
D) Amplitude
سؤال
A DSO and a ________ are useful tools when diagnosing a fuel pump circuit.

A) hose clamp
B) current clamp
C) vacuum transducer
D) test light
سؤال
With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________. <strong>With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________.  </strong> A) 8 volts; 500mS B) 1 volt; 1 second C) 1 volt; 500 mS D) None of these <div style=padding-top: 35px>

A) 8 volts; 500mS
B) 1 volt; 1 second
C) 1 volt; 500 mS
D) None of these
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 4: Oscilloscopes and Dsos
1
A signal showing the voltage of a battery displayed on an analog oscilloscope is being discussed. Technician A says that the display will show one horizontal line above the zero line. Technician B says that the display will show a line sloping upward from zero to the battery voltage level. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
A
2
A TP sensor signal voltage is being observed using a digital storage oscilloscope. The pattern on the scope occasionally rises to the source voltage level. What does this indicate?

A) Normal operation
B) A momentary short in the TP sensor
C) A momentary open circuit
D) A fault with the scope leads
B
3
Two technicians are discussing pulse train signals. Technician A says that a pulse train is a DC signal waveform that goes above and below zero volts. Technician B says that a pulse train is a DC voltage that turns on and off in a series of pulses and they do not go below zero. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
B
4
Which type of oscilloscope displays all voltages without taking samples?

A) Complex
B) Analog
C) Digital
D) None of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
Technician A says that analog scopes use an LCD display. Technician B says that digital scopes may use a CRT display. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
A digital storage oscilloscope is set to begin displaying a waveform when a certain voltage is detected. This minimum voltage is called ________.

A) threshold
B) trigger
C) trip
D) None of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
A typical DSO display screen is arranged in an ________ grid.

A) 6 × 8
B) 8 × 10
C) 8 × 8
D) None of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
Technician A says that voltage is usually indicated on the horizontal display axis. Technician B says that time is usually indicated on the horizontal display axis. Which technician is correct?

A) Technician A only
B) Technician B only
C) Both technicians A and B
D) Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
________ the time base setting reduces the number of samples per second.

A) Increasing
B) Dividing
C) Decreasing
D) None of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
A time base setting of 1ms/div will show a total time of ________ on the scope display

A) 100 ms
B) 1 ms
C) 10 ms
D) None of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Which is the correct voltage division setting for testing a throttle position sensor?

A) 1V
B) 3V
C) 5V
D) 10V
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
Which of these is measured as a percentage?

A) Pulse width
B) Duty cycle
C) Dwell
D) None of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of these terms is a measure of the actual on-time measured in milliseconds?

A) Period
B) Pulse width
C) Frequency
D) Amplitude
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
A DSO and a ________ are useful tools when diagnosing a fuel pump circuit.

A) hose clamp
B) current clamp
C) vacuum transducer
D) test light
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________. <strong>With the scope set as shown, the maximum voltage to be measured is ________ and the time displayed will be ________.  </strong> A) 8 volts; 500mS B) 1 volt; 1 second C) 1 volt; 500 mS D) None of these

A) 8 volts; 500mS
B) 1 volt; 1 second
C) 1 volt; 500 mS
D) None of these