Deck 8: Signal Monitoring

ملء الشاشة (f)
exit full mode
سؤال
When analyzing the video signal on a waveform monitor, the view of the signal can be changed and certain parts enlarged.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Active video when viewed as luminance only occupies the range between 7.5 and 1000 units or IRE.
سؤال
Because some of the color information on a normal color bar display would be beyond the waveform monitor's measuring limits, a color bar signal reduced to 75% of true levels is the general standard in use.
سؤال
The horizontal sync pulse should be at the -40 units line.
سؤال
The Low Pass filter on a waveform monitor (LPASS) selects the luminance portion of the signal only.
سؤال
Waveform monitors and vectorscopes are both measuring tools also known

A) oscillators
B) oscilloscopes
C) zoetropes
D) none of the above
سؤال
In front of the CRT of a scope is a glass or plastic plate made up of vertical and horizontal lines used to measure the video signal. This plate is called the

A) scale
B) face
C) target
D) graticule
سؤال
The scale on a waveform monitor that ranges from -40 to 100 IRE was referred to as how many volts of peak-to-peak video?

A) One
B) 1/1000
C) 3.58 volts
D) 100
سؤال
The horizontal line at zero units on a waveform monitor is referred to as the

A) zero line
B) base line
C) unit line
D) timing line
سؤال
The horizontal line at zero units is marked with vertical divisions in

A) milliseconds
B) microseconds
C) tenths of microseconds
D) both B and C
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 8: Signal Monitoring
1
When analyzing the video signal on a waveform monitor, the view of the signal can be changed and certain parts enlarged.
True
2
Active video when viewed as luminance only occupies the range between 7.5 and 1000 units or IRE.
False
3
Because some of the color information on a normal color bar display would be beyond the waveform monitor's measuring limits, a color bar signal reduced to 75% of true levels is the general standard in use.
True
4
The horizontal sync pulse should be at the -40 units line.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
The Low Pass filter on a waveform monitor (LPASS) selects the luminance portion of the signal only.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
Waveform monitors and vectorscopes are both measuring tools also known

A) oscillators
B) oscilloscopes
C) zoetropes
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
In front of the CRT of a scope is a glass or plastic plate made up of vertical and horizontal lines used to measure the video signal. This plate is called the

A) scale
B) face
C) target
D) graticule
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
The scale on a waveform monitor that ranges from -40 to 100 IRE was referred to as how many volts of peak-to-peak video?

A) One
B) 1/1000
C) 3.58 volts
D) 100
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
The horizontal line at zero units on a waveform monitor is referred to as the

A) zero line
B) base line
C) unit line
D) timing line
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
The horizontal line at zero units is marked with vertical divisions in

A) milliseconds
B) microseconds
C) tenths of microseconds
D) both B and C
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.