Deck 5: Practical Conductors and Insulators

ملء الشاشة (f)
exit full mode
سؤال
In the electrical industry, 'wires' are generally referred to as

A) flex'
B) conductors'
C) cores'
D) cables'
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Place the following conductors in order, from best to worst in terms of their conductivity: aluminium, silver, gold, and copper

A) gold, silver, copper, aluminium
B) silver, gold, copper, aluminium
C) silver, copper, gold, aluminium
D) silver, copper, aluminium, gold
سؤال
What property makes aluminium generally unsuitable for domestic wiring systems?

A) poor conductivity compared to copper
B) unreliable pressure connections due to 'cold flow'
C) poor conducting quality of its corrosive film
D) low melting point
سؤال
A 'cable' consists of

A) one or more conductors
B) one or more insulated conductors
C) one or more insulated conductors enclosed in a protective sheath
سؤال
The term, 'live conductors', refers to a cable's

A) line conductor(s)
B) neutral conductor
C) line and neutral conductors
D) line, neutral, and earth conductors
سؤال
A cable, comprising a line, neutral, and protective (earth) conductor, is termed a

A) single-core conductor'
B) two-core conductor'
C) three-core conductor'
سؤال
Stranded conductors are manufactured to

A) ease their manufacture
B) increase their current ratings
C) increase the flexibility of a cable
D) improve their heat dissipation
سؤال
For a stranded '7/0.85' cable, the figure '0.85' refers to the

A) the diameter of individual strands
B) the cross-sectional area of individual strands
C) the diameter of the conductor
D) the cross-sectional area of the conductor
سؤال
Cables with 'wedge-shaped' cores are manufactured to

A) improve their current-carrying capacity
B) reduce the electrical stress within their insulation
C) improve their flexibility
D) reduce their overall diameter
سؤال
The purpose of a cable's outer sheath is to

A) provide limited mechanical protection
B) prevent the ingress of moisture
C) contain the individual cores
D) all of the above
سؤال
The purpose of armouring a cable is to

A) protect it against mechanical damage
B) relieve and electric stress
C) prevent the ingress of moisture
D) all of the above
سؤال
Insulation is specified, within the UK's Wiring Regulations, in terms of

A) the materials from which it is manufactured
B) its anticipated operating temperature
C) its method of manufacture
D) its insulation resistance
سؤال
The maximum electric field that can be sustained by a dielectric before breakdown occurs' describes an insulator's

A) insulation resistance
B) dielectric strength
C) resistivity
D) voltage gradient
سؤال
For cables manufactured for use in the EU, the insulation colour for a line conductor is

A) red
B) brown
C) black
D) blue
سؤال
For cables manufactured for use in the EU, the insulation colour for a neutral conductor is

A) red
B) brown
C) black
D) blue
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 5: Practical Conductors and Insulators
1
In the electrical industry, 'wires' are generally referred to as

A) flex'
B) conductors'
C) cores'
D) cables'
conductors'
2
Place the following conductors in order, from best to worst in terms of their conductivity: aluminium, silver, gold, and copper

A) gold, silver, copper, aluminium
B) silver, gold, copper, aluminium
C) silver, copper, gold, aluminium
D) silver, copper, aluminium, gold
silver, copper, gold, aluminium
3
What property makes aluminium generally unsuitable for domestic wiring systems?

A) poor conductivity compared to copper
B) unreliable pressure connections due to 'cold flow'
C) poor conducting quality of its corrosive film
D) low melting point
unreliable pressure connections due to 'cold flow'
4
A 'cable' consists of

A) one or more conductors
B) one or more insulated conductors
C) one or more insulated conductors enclosed in a protective sheath
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
The term, 'live conductors', refers to a cable's

A) line conductor(s)
B) neutral conductor
C) line and neutral conductors
D) line, neutral, and earth conductors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
A cable, comprising a line, neutral, and protective (earth) conductor, is termed a

A) single-core conductor'
B) two-core conductor'
C) three-core conductor'
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
Stranded conductors are manufactured to

A) ease their manufacture
B) increase their current ratings
C) increase the flexibility of a cable
D) improve their heat dissipation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
For a stranded '7/0.85' cable, the figure '0.85' refers to the

A) the diameter of individual strands
B) the cross-sectional area of individual strands
C) the diameter of the conductor
D) the cross-sectional area of the conductor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
Cables with 'wedge-shaped' cores are manufactured to

A) improve their current-carrying capacity
B) reduce the electrical stress within their insulation
C) improve their flexibility
D) reduce their overall diameter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
The purpose of a cable's outer sheath is to

A) provide limited mechanical protection
B) prevent the ingress of moisture
C) contain the individual cores
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
The purpose of armouring a cable is to

A) protect it against mechanical damage
B) relieve and electric stress
C) prevent the ingress of moisture
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
Insulation is specified, within the UK's Wiring Regulations, in terms of

A) the materials from which it is manufactured
B) its anticipated operating temperature
C) its method of manufacture
D) its insulation resistance
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
The maximum electric field that can be sustained by a dielectric before breakdown occurs' describes an insulator's

A) insulation resistance
B) dielectric strength
C) resistivity
D) voltage gradient
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
For cables manufactured for use in the EU, the insulation colour for a line conductor is

A) red
B) brown
C) black
D) blue
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
For cables manufactured for use in the EU, the insulation colour for a neutral conductor is

A) red
B) brown
C) black
D) blue
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.