Deck 8: Assessment of Pulmonary Function

ملء الشاشة (f)
exit full mode
سؤال
What speed should be used for the rotating drum of a water-sealed spirometer to measure volume changes during a forced vital capacity maneuver?

A) 16 mm/min
B) 32 mm/min
C) 160 mm/min
D) 1920 mm/min
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The bell factor for a 9-L water-sealed spirometer bell is _____ mL/mm.

A) 13.5
B) 29.3
C) 20.93
D) 41.73
سؤال
"An aluminum bell suspended by a chain-and-pulley mechanism with a weight that counterbalances the weight of the bell" describes which of the following?

A) Dry rolling spirometer
B) Water-sealed spirometer
C) Bellows spirometer
D) Pneumotachograph
سؤال
Which type of flow-measuring device uses struts to create a partial obstruction to gas flow,causing whirlpools to be produced when gas flows through it?

A) Monel pneumotachograph
B) Ceramic pneumotachograph
C) Vortex ultrasonic flowmeter
D) Variable-orifice pneumotachograph
سؤال
What is the volume displacement when the pen of a 13.5-L water-sealed spirometer moves 28 mm?

A) 0.378 L
B) 0.563 L
C) 0.586 L
D) 1.168 L
سؤال
The visual picture of volume and flow measurements is known as which of the following?

A) Spirogram
B) Spirometer
C) Kymograph
D) Turbine flowmeter
سؤال
Which of the following is a volume-collecting device?

A) Turbine flowmeter
B) Thermal anemometer
C) Dry rolling seal spirometer
D) Pressure pneumotachograph
سؤال
Which of the following devices is bidirectional?

A) Turbine flowmeter
B) Screen pneumotachograph
C) Vortex ultrasonic flowmeter
D) Variable-orifice pneumotachograph
سؤال
Peak flowmeters are calibrated in which of the following units?

A) liters/second
B) liters/minute
C) milliliters/second
D) millimeters/minute
سؤال
________ is used to measure lung-volume changes by collecting exhaled gas into an expandable wedge-shaped device.

A) A bellows spirometer
B) A water-sealed spirometer
C) A vortex pneumotachometer
D) A screen pneumotachometer
سؤال
The accuracy of an instrument depends on which of the following?
1)The standard deviation of repeated measurements
2)The instrument's linearity and frequency response
3)The instrument's ability to reproduce a measurement
4)The instrument's sensitivity to environmental conditions

A) 1 and 2
B) 1 and 3
C) 2 and 3
D) 2 and 4
سؤال
What is the tidal volume measurement when the pen of a 9-L water-sealed spirometer moves 25 mm?

A) 0.338 L
B) 0.523 L
C) 0.843 L
D) 1.043 L
سؤال
Which statement is true concerning thermal flowmeters?

A) Gas flow can be measured bidirectionally.
B) Gas velocity affects the amount of cooling.
C) Cooling increases the resistance of a heated wire.
D) Cooling decreases the resistance of a thermistor bead.
سؤال
Speed settings of 32 and 160 mm/min on a water-sealed spirometer can be used to measure which of the following?
1)Minute ventilation
2)Peak expiratory flows
3)Maximum voluntary ventilation
4)Forced vital capacity maneuvers

A) 1 and 2
B) 1 and 3
C) 2 and 4
D) 3 and 4
سؤال
The rotating motor-driven drum used to document the bell movement of a water-sealed spirometer is known as which of the following?

A) Spirograph
B) Kymograph
C) Anemometer
D) Pneumotachograph
سؤال
Which of the following is true concerning the Stead-Wells spirometer?

A) Counterweights are necessary.
B) The pen and bell move in opposite directions.
C) The pen recorder is attached directly to the bell.
D) On exhalation, the bell and pen move downward.
سؤال
The precision of an instrument depends on:

A) linearity.
B) calibration.
C) repeatability.
D) frequency of response.
سؤال
The principle that gas flow is proportional to the pressure drop across a known resistance is used by which of the following devices?

A) Turbine flowmeter
B) Thermal flowmeter
C) Fleisch pneumotachograph
D) Ultrasonic pneumotachograph
سؤال
Airflow is measured by which of the following?

A) "Hot-wire" anemometer
B) Bellows spirometer
C) Water-sealed spirometer
D) Dry rolling seal spirometer
سؤال
When a patient inhales while connected to a water-sealed spirometer,the bell moves _____ and the pen moves _____.

A) Up; up
B) Up; down
C) Down; up
D) Down; down
سؤال
The bedside respiratory mechanics of mechanically ventilated patients can be measured with which of the following?
1)VenTrak system
2)Tissot spirometer
3)BICORE CP-100 system
4)Stead-Wells spirometer

A) 1 and 2
B) 1 and 3
C) 2 and 3
D) 2 and 4
سؤال
The best method for accurately measuring the thoracic gas volume of a patient with emphysema is:

A) helium dilution.
B) nitrogen washout.
C) pressure plethysmography.
D) chemiluminescence monitoring.
سؤال
A screen pneumotachograph is:

A) built with metal struts.
B) expensive and non-disposable.
C) bidirectional and very accurate.
D) heated to prevent condensation.
سؤال
Body plethysmography is based on which of the following gas laws?

A) Boyle's
B) Charles'
C) Dalton's
D) Gay-Lussac's
سؤال
Which of the following are factors that influence the partial pressure of alveolar carbon dioxide (PACO₂)?
1)Diffusion
2)Ventilation
3)CO₂ production
4)Perfusion of the lungs

A) 1 and 2
B) 2 and 3
C) 1,3,and 4
D) 1,2,3,and 4
سؤال
Which of the following represents the relationship used by body plethysmography to calculate functional residual capacity?

A) VFRC=ΔV÷ΔP×(PBPH2O) V_{F R C}=\Delta V \div \Delta P \times\left(P_{B}-P_{H 2 O}\right)
B) VFRC=ΔP÷ΔV×(PBPH2O) \mathrm{V}_{\mathrm{FRC}}=\Delta \mathrm{P} \div \Delta \mathrm{V} \times\left(\mathrm{P}_{\mathrm{B}}-\mathrm{P}_{\mathrm{H} 2 \mathrm{O}}\right)
C) VFRC=ΔV÷ΔT×(PBPH2O) \mathrm{V}_{\mathrm{FRC}}=\Delta \mathrm{V} \div \Delta \mathrm{T} \times\left(\mathrm{P}_{\mathrm{B}}-\mathrm{P}_{\mathrm{H} 2 \mathrm{O}}\right)
D) VFRC=(PBPH2O)×ΔV\mathrm { V } _ { \mathrm { FRC } } = \left( \mathrm { P } _ { \mathrm { B } } - \mathrm { P } _ { \mathrm { H } 2 \mathrm { O } } \right) \times \Delta \mathrm { V }
سؤال
The parents of a newborn sent home with an apnea monitor call the respiratory therapist to report several periods of apnea as noted by the monitor's alarm system.The respiratory therapist should check which of the following to ensure that the baby's movement was not the cause of these alarms?

A) Sensitivity of the monitor
B) Placement of the electrodes
C) Amount of electrical current
D) Frequency of the vibrations
سؤال
Which type of pressure-measurement device is best suited to measure arterial blood pressure through an arterial catheter?

A) Bourdon gauge
B) Aneroid manometer
C) Variable inductance
D) Variable capacitance
سؤال
Which of the following equipment is necessary to perform a nitrogen washout test?

A) Pneumotachometer
B) Carbon dioxide (CO₂) absorber
C) Drying column
D) Pressure transducer
سؤال
The standard for repeatability for forced expiratory volume in 1 second (FEV₁)is ___ mL.

A) 100
B) 150
C) 200
D) 250
سؤال
Which of the following might cause an apnea monitor to fail to alert the clinician to the presence of apnea?

A) Tachycardia
B) Changes in blood volume
C) Upper airway obstruction
D) Inadequate Sensitivity settings
سؤال
"Opposition to the flow of an alternating current" is the definition of:

A) electrical resistance.
B) variable capacitance.
C) electrical impedance.
D) variable inductance.
سؤال
Impedance plethysmographs operate by using _____-frequency,_____-amplitude electrical current.

A) Low; low
B) High; low
C) Low; high
D) High; high
سؤال
Which type of pneumotachograph uses the Doppler effect to measure airflow velocity?

A) Fleisch
B) Screen type
C) Nonvortex
D) Variable-orifice
سؤال
Which of the following is true concerning the triple-lumen esophageal catheter used with the BICORE CP-100 Pulmonary Monitoring System?

A) It can measure intrapleural pressure indirectly.
B) Its ideal position is the upper third of the esophagus.
C) When the catheter enters the stomach, a negative pressure is recorded.
D) The catheter can be positioned by observing the markings on its side.
سؤال
One type of ventilatory pattern necessary for calculating functional residual capacity through the use of a body plethysmograph is:

A) deep breathing with a breath hold.
B) rapid, shallow breathing.
C) deep, rapid breathing.
D) slow, deep breathing.
سؤال
The end point of a helium dilution test occurs when:

A) nitrogen is washed out.
B) there is no more helium.
C) the change in pressure remains steady.
D) the helium percentage remains steady for 2 minutes.
سؤال
A comparison of functional residual capacity measured by body plethysmography with that measured by nitrogen washout reveals that the measurement obtained during the nitrogen washout test is less than that during body plethysmography.This discrepancy is most likely caused by which of the following?

A) Poor technique
B) Severe air-trapping
C) Restrictive lung disease
D) Directional valve malfunction
سؤال
Which type of pressure-measurement device is used to measure a patient's maximum inspiratory pressure?

A) Variable inductance
B) Aneroid manometer
C) Plethysmograph
D) Strain gauge
سؤال
Aneroid manometers use ________ to measure pressure.

A) a vacuum chamber with a flexible diaphragm
B) capacitance and changes in output voltage
C) changes in inductance of two coils
D) a Wheatstone bridge circuit
سؤال
Patients with restrictive pulmonary disease demonstrate a decrease in which of the following measurements?
1)Vital capacity
2)Total lung capacity
3)Forced expiratory flow from 25% to 75% of the vital capacity (FEF₂₅₋₇₅)
4)Ratio of forced expiratory volume in 1 second to vital capacity (FEV₁/VC)

A) 1 and 2
B) 2 and 3
C) 1 and 4
D) 3 and 4
سؤال
While working in the neonatal intensive care unit,a respiratory therapist notices that a baby with an apnea monitor is not breathing,but the apnea alarm is not ringing.Which of the following might cause this failure?
1)Tachypnea
2)Bradycardia
3)Excessive movement
4)Upper airway obstruction

A) 1 and 2
B) 2 and 4
C) 1 and 3
D) 3 and 4
سؤال
If a patient's minute volume is 8.5 L/min and his respiratory rate is 15 breaths/min,his average tidal volume is ____ L.

A) 0.125
B) 0.570
C) 0.060
D) 5.700
سؤال
Total lung capacity is a result of:

A) vital capacity plus residual volume.
B) inspiratory capacity plus residual volume.
C) inspiratory capacity plus expiratory residual volume.
D) inspiratory reserve volume plus functional residual capacity.
سؤال
What type of device is used in an ICU to detect respiratory muscle fatigue?

A) Aneroid manometer
B) Pressure plethysmograph
C) Inductive plethysmograph
D) Electromechanical transducer
سؤال
Which device would be appropriate for monitoring respiratory rate and tidal volume during a sleep study?

A) Capnograph
B) Mass spectrometer
C) Pneumotachograph
D) Inductive plethysmograph
سؤال
Secretions in the airway of a mechanically ventilated patient could be indicated by a(n):

A) increase in inspiratory capacity.
B) increase in breathing frequency.
C) increase in peak inspiratory pressure.
D) decrease in forced expiratory flow rates.
سؤال
Which of the following devices can a patient with asthma use in the home to monitor daily variations in Raw?

A) Thermal flowmeter
B) Fleisch pneumotachograph
C) Screen pneumotachograph
D) Vortex ultrasonic flowmeter
سؤال
Which of the following values is not measured directly?

A) FEV₁
B) Airway resistance (Raw)
C) Peak expiratory flows
D) Maximum inspiratory pressure
سؤال
As measured by inductive plethysmography,rib cage movement plus abdominal movement equals:

A) tidal volume.
B) inspiratory capacity.
C) expiratory reserve volume.
D) functional residual capacity.
سؤال
Newer ventilators can make tidal volume and minute volume measurements by incorporating which of the following?

A) Capnograph
B) Anemometer
C) Flow transducer
D) Pressure transducer
سؤال
To set up a pulmonary function laboratory that can measure all standard and dynamic lung volumes,which of the following equipment is necessary?

A) Screen pneumotachograph and inductive plethysmograph
B) Fleisch pneumotachograph and peak flowmeter
C) Vortex ultrasonic flowmeter and inductive plethysmograph
D) Stead-Wells spirometer and constant-volume plethysmograph
سؤال
The results of pulmonary function testing show a normal total lung capacity and decreased,but reversible,FEV₁ and FEV₂₅₋₇₅.The patient is a 22-year-old,nonsmoking man with a history of intermittent "noisy breathing." Which of the following is most likely the cause of his problem?

A) Asthma
B) Emphysema
C) Pulmonary fibrosis
D) Severe restrictive pulmonary disease
سؤال
The most appropriate lung volume to measure for a mechanically ventilated patient is _____ volume.

A) minute
B) residual
C) expiratory reserve
D) inspiratory reserve
سؤال
Increased alveolar ventilation is associated with which of the following?

A) Hyperthermia
B) Bronchospasm
C) Decreased metabolic rate
D) Respiratory muscle fatigue
سؤال
The principle that the respiratory system moves with 2 degrees of freedom describes the basis for which of the following?

A) Inductive plethysmography
B) Volume plethysmography
C) Strain gauge transducer
D) Nitrogen washout
سؤال
Which of the following variables can be measured directly?

A) Lung compliance
B) Work of breathing
C) Raw
D) Pₚₗₐₜₑₐᵤ
سؤال
Vital capacity is the sum of which of the following?
1)Residual volume
2)Inspiratory capacity
3)Expiratory reserve volume
4)Inspiratory reserve volume
5)Functional residual capacity

A) 2 and 3
B) 1 and 4
C) 2 and 5
D) 3 and 4
سؤال
Expiratory residual volume plus residual volume equals:

A) functional residual capacity.
B) inspiratory capacity.
C) total lung capacity.
D) vital capacity.
سؤال
What is the minute volume of a patient if her respiratory rate is 12 breaths/min and her tidal volume is 750 mL?

A) 0.06 L
B) 9.00 L
C) 6.25 L
D) 9.00 L
سؤال
Which oxygen analyzer uses a semipermeable polytetrafluoroethylene membrane to separate oxygen from a potassium hydroxide bath containing a gold cathode and a lead anode?

A) Paramagnetic
B) Galvanic
C) Electrical
D) Polarographic
سؤال
Which device is appropriate for assessing a patient's response to bronchodilator therapy at the bedside?

A) Stead-Wells spirometer
B) Mainstream capnograph
C) Inductive plethysmograph
D) Rotating-vane flowmeter
سؤال
Which of the following pathophysiologic conditions can increase both the peak inspiratory pressure and the Pₚₗₐₜₑₐᵤ of a ventilated patient?

A) Asthma
B) Atelectasis
C) Kyphoscoliosis
D) Pulmonary interstitial fibrosis
سؤال
The respiratory system compliance of a patient receiving mechanical ventilation when the returned tidal volume is 650 mL,the static pressure is 35 cm H₂O,and the positive end-expiratory pressure is 8 cm H₂O is _____ mL/cm H₂O.

A) 0.04
B) 18.6
C) 53.9
D) 24
سؤال
Which of the following variables in the formula describing Poiseuille's law can be altered in the clinical setting to improve Raw?
1)Radius of the airways
2)Viscosity of the inspired gas
3)Flow rate of the inspired gas
4)Temperature of the inspired gas
5)Length of the tracheobronchial tree

A) 1 and 3
B) 1,4,and 5
C) 2,3,and 5
D) 1,2,and 3
سؤال
The amount of pressure required by a ventilator to maintain tidal volume when there is no gas flow is known as:

A) Pₚₗₐₜₑₐᵤ.
B) peak inspiratory pressure.
C) peak expiratory pressure.
D) Maximum inspiratory pressure.
سؤال
A(n)______ analyzer is an oxygen analyzer that uses paramagnetism to measure oxygen concentration.

A) Galvanic
B) Electrical
C) Paramagnetic
D) Polarographic
سؤال
Normal Raw of the respiratory system is _____ cm H₂O/L/s.

A) 1 to 3
B) 2 to 5
C) 4 to 8
D) 6 to 10
سؤال
Occlusion of the expiratory valve of the ventilator at the end of a tidal inspiration enables measurement of which of the following?

A) Pₚₗₐₜₑₐᵤ
B) Peak airway pressure
C) Maximum inspiratory pressure
D) Maximum expiratory pressure
سؤال
Which type of oxygen analyzer will give erroneous concentration levels in the presence of contaminant gases?

A) Polarographic
B) Electrical
C) Galvanic
D) Physical
سؤال
The oxygen analyzer that is no longer commonly used is the ____ analyzer.

A) Paramagnetic
B) Galvanic
C) Electrical
D) Polarographic
سؤال
Electrical analyzers operate by using which of the following?

A) Clark electrodes
B) Pauling's principle
C) Thermal conductivity
D) Oxygen-mediated chemical reaction
سؤال
What is the pressure reading on the anemometer of a ventilator during an inspiratory hold maneuver?

A) Pₚₗₐₜₑₐᵤ.
B) Peak inspiratory pressure
C) Mean inspiratory pressure
D) Maximum inspiratory pressure
سؤال
Which device can be incorporated into a ventilator to provide continuous recordings of airway pressure during the breathing cycle?

A) Variable capacitance transducer
B) Inductive plethysmograph
C) Strain gauge transducer
D) Aneroid manometer
سؤال
Which of the following happen to the wire within a Wheatstone bridge when it is exposed to oxygen concentrations higher than room air?
1)Its resistance decreases.
2)Its resistance increases.
3)It cools down.
4)It heats up.

A) 1 and 4
B) 2 and 3
C) 1 and 4
D) 1 and 3
سؤال
Which of the following is a complication of performing peak expiratory flows maneuvers?

A) Increased static pressure
B) Increased airway resistance
C) Decreased chest compliance
D) Decreased mean airway pressure
سؤال
A(n)______ analyzer is an oxygen analyzer that can display both partial pressure (in millimeters of mercury)and the percentage of oxygen concentration.

A) Paramagnetic
B) Galvanic
C) Electrical
D) Polarographic
سؤال
If the chest wall compliance of a mechanically ventilated patient decreases,which of the following will occur?

A) Maximum inspiratory pressure will decrease.
B) Peak inspiratory pressure will decrease.
C) Pₚₗₐₜₑₐᵤ will increase.
D) Tidal volume will increase.
سؤال
Which type of oxygen analyzer should not be used in the presence of anesthetic gases?

A) Polarographic
B) Paramagnetic
C) Electrical
D) Galvanic
سؤال
Which gas law is applicable when considering Raw?

A) Boyle's
B) Charles'
C) Poiseuille's
D) Avogadro's
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/120
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 8: Assessment of Pulmonary Function
1
What speed should be used for the rotating drum of a water-sealed spirometer to measure volume changes during a forced vital capacity maneuver?

A) 16 mm/min
B) 32 mm/min
C) 160 mm/min
D) 1920 mm/min
D
The fastest speed (1920 mm/min)is used for recording volume changes during forced vital capacity maneuvers.
2
The bell factor for a 9-L water-sealed spirometer bell is _____ mL/mm.

A) 13.5
B) 29.3
C) 20.93
D) 41.73
C
The bell factor is the number of milliliters of gas that must be displaced to cause the kymographic pen to move 1 mm.The bell factor for a 9-L bell is 20.93 mL/mm.
3
"An aluminum bell suspended by a chain-and-pulley mechanism with a weight that counterbalances the weight of the bell" describes which of the following?

A) Dry rolling spirometer
B) Water-sealed spirometer
C) Bellows spirometer
D) Pneumotachograph
B
This is the description of a water-sealed spirometer.
4
Which type of flow-measuring device uses struts to create a partial obstruction to gas flow,causing whirlpools to be produced when gas flows through it?

A) Monel pneumotachograph
B) Ceramic pneumotachograph
C) Vortex ultrasonic flowmeter
D) Variable-orifice pneumotachograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is the volume displacement when the pen of a 13.5-L water-sealed spirometer moves 28 mm?

A) 0.378 L
B) 0.563 L
C) 0.586 L
D) 1.168 L
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
6
The visual picture of volume and flow measurements is known as which of the following?

A) Spirogram
B) Spirometer
C) Kymograph
D) Turbine flowmeter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which of the following is a volume-collecting device?

A) Turbine flowmeter
B) Thermal anemometer
C) Dry rolling seal spirometer
D) Pressure pneumotachograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
8
Which of the following devices is bidirectional?

A) Turbine flowmeter
B) Screen pneumotachograph
C) Vortex ultrasonic flowmeter
D) Variable-orifice pneumotachograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
9
Peak flowmeters are calibrated in which of the following units?

A) liters/second
B) liters/minute
C) milliliters/second
D) millimeters/minute
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
10
________ is used to measure lung-volume changes by collecting exhaled gas into an expandable wedge-shaped device.

A) A bellows spirometer
B) A water-sealed spirometer
C) A vortex pneumotachometer
D) A screen pneumotachometer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
11
The accuracy of an instrument depends on which of the following?
1)The standard deviation of repeated measurements
2)The instrument's linearity and frequency response
3)The instrument's ability to reproduce a measurement
4)The instrument's sensitivity to environmental conditions

A) 1 and 2
B) 1 and 3
C) 2 and 3
D) 2 and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
12
What is the tidal volume measurement when the pen of a 9-L water-sealed spirometer moves 25 mm?

A) 0.338 L
B) 0.523 L
C) 0.843 L
D) 1.043 L
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which statement is true concerning thermal flowmeters?

A) Gas flow can be measured bidirectionally.
B) Gas velocity affects the amount of cooling.
C) Cooling increases the resistance of a heated wire.
D) Cooling decreases the resistance of a thermistor bead.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
14
Speed settings of 32 and 160 mm/min on a water-sealed spirometer can be used to measure which of the following?
1)Minute ventilation
2)Peak expiratory flows
3)Maximum voluntary ventilation
4)Forced vital capacity maneuvers

A) 1 and 2
B) 1 and 3
C) 2 and 4
D) 3 and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
15
The rotating motor-driven drum used to document the bell movement of a water-sealed spirometer is known as which of the following?

A) Spirograph
B) Kymograph
C) Anemometer
D) Pneumotachograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
16
Which of the following is true concerning the Stead-Wells spirometer?

A) Counterweights are necessary.
B) The pen and bell move in opposite directions.
C) The pen recorder is attached directly to the bell.
D) On exhalation, the bell and pen move downward.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
17
The precision of an instrument depends on:

A) linearity.
B) calibration.
C) repeatability.
D) frequency of response.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
18
The principle that gas flow is proportional to the pressure drop across a known resistance is used by which of the following devices?

A) Turbine flowmeter
B) Thermal flowmeter
C) Fleisch pneumotachograph
D) Ultrasonic pneumotachograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
19
Airflow is measured by which of the following?

A) "Hot-wire" anemometer
B) Bellows spirometer
C) Water-sealed spirometer
D) Dry rolling seal spirometer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
20
When a patient inhales while connected to a water-sealed spirometer,the bell moves _____ and the pen moves _____.

A) Up; up
B) Up; down
C) Down; up
D) Down; down
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
21
The bedside respiratory mechanics of mechanically ventilated patients can be measured with which of the following?
1)VenTrak system
2)Tissot spirometer
3)BICORE CP-100 system
4)Stead-Wells spirometer

A) 1 and 2
B) 1 and 3
C) 2 and 3
D) 2 and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
22
The best method for accurately measuring the thoracic gas volume of a patient with emphysema is:

A) helium dilution.
B) nitrogen washout.
C) pressure plethysmography.
D) chemiluminescence monitoring.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
23
A screen pneumotachograph is:

A) built with metal struts.
B) expensive and non-disposable.
C) bidirectional and very accurate.
D) heated to prevent condensation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
24
Body plethysmography is based on which of the following gas laws?

A) Boyle's
B) Charles'
C) Dalton's
D) Gay-Lussac's
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
25
Which of the following are factors that influence the partial pressure of alveolar carbon dioxide (PACO₂)?
1)Diffusion
2)Ventilation
3)CO₂ production
4)Perfusion of the lungs

A) 1 and 2
B) 2 and 3
C) 1,3,and 4
D) 1,2,3,and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
26
Which of the following represents the relationship used by body plethysmography to calculate functional residual capacity?

A) VFRC=ΔV÷ΔP×(PBPH2O) V_{F R C}=\Delta V \div \Delta P \times\left(P_{B}-P_{H 2 O}\right)
B) VFRC=ΔP÷ΔV×(PBPH2O) \mathrm{V}_{\mathrm{FRC}}=\Delta \mathrm{P} \div \Delta \mathrm{V} \times\left(\mathrm{P}_{\mathrm{B}}-\mathrm{P}_{\mathrm{H} 2 \mathrm{O}}\right)
C) VFRC=ΔV÷ΔT×(PBPH2O) \mathrm{V}_{\mathrm{FRC}}=\Delta \mathrm{V} \div \Delta \mathrm{T} \times\left(\mathrm{P}_{\mathrm{B}}-\mathrm{P}_{\mathrm{H} 2 \mathrm{O}}\right)
D) VFRC=(PBPH2O)×ΔV\mathrm { V } _ { \mathrm { FRC } } = \left( \mathrm { P } _ { \mathrm { B } } - \mathrm { P } _ { \mathrm { H } 2 \mathrm { O } } \right) \times \Delta \mathrm { V }
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
27
The parents of a newborn sent home with an apnea monitor call the respiratory therapist to report several periods of apnea as noted by the monitor's alarm system.The respiratory therapist should check which of the following to ensure that the baby's movement was not the cause of these alarms?

A) Sensitivity of the monitor
B) Placement of the electrodes
C) Amount of electrical current
D) Frequency of the vibrations
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
28
Which type of pressure-measurement device is best suited to measure arterial blood pressure through an arterial catheter?

A) Bourdon gauge
B) Aneroid manometer
C) Variable inductance
D) Variable capacitance
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
29
Which of the following equipment is necessary to perform a nitrogen washout test?

A) Pneumotachometer
B) Carbon dioxide (CO₂) absorber
C) Drying column
D) Pressure transducer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
30
The standard for repeatability for forced expiratory volume in 1 second (FEV₁)is ___ mL.

A) 100
B) 150
C) 200
D) 250
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
31
Which of the following might cause an apnea monitor to fail to alert the clinician to the presence of apnea?

A) Tachycardia
B) Changes in blood volume
C) Upper airway obstruction
D) Inadequate Sensitivity settings
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
32
"Opposition to the flow of an alternating current" is the definition of:

A) electrical resistance.
B) variable capacitance.
C) electrical impedance.
D) variable inductance.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
33
Impedance plethysmographs operate by using _____-frequency,_____-amplitude electrical current.

A) Low; low
B) High; low
C) Low; high
D) High; high
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
34
Which type of pneumotachograph uses the Doppler effect to measure airflow velocity?

A) Fleisch
B) Screen type
C) Nonvortex
D) Variable-orifice
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
35
Which of the following is true concerning the triple-lumen esophageal catheter used with the BICORE CP-100 Pulmonary Monitoring System?

A) It can measure intrapleural pressure indirectly.
B) Its ideal position is the upper third of the esophagus.
C) When the catheter enters the stomach, a negative pressure is recorded.
D) The catheter can be positioned by observing the markings on its side.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
36
One type of ventilatory pattern necessary for calculating functional residual capacity through the use of a body plethysmograph is:

A) deep breathing with a breath hold.
B) rapid, shallow breathing.
C) deep, rapid breathing.
D) slow, deep breathing.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
37
The end point of a helium dilution test occurs when:

A) nitrogen is washed out.
B) there is no more helium.
C) the change in pressure remains steady.
D) the helium percentage remains steady for 2 minutes.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
38
A comparison of functional residual capacity measured by body plethysmography with that measured by nitrogen washout reveals that the measurement obtained during the nitrogen washout test is less than that during body plethysmography.This discrepancy is most likely caused by which of the following?

A) Poor technique
B) Severe air-trapping
C) Restrictive lung disease
D) Directional valve malfunction
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
39
Which type of pressure-measurement device is used to measure a patient's maximum inspiratory pressure?

A) Variable inductance
B) Aneroid manometer
C) Plethysmograph
D) Strain gauge
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
40
Aneroid manometers use ________ to measure pressure.

A) a vacuum chamber with a flexible diaphragm
B) capacitance and changes in output voltage
C) changes in inductance of two coils
D) a Wheatstone bridge circuit
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
41
Patients with restrictive pulmonary disease demonstrate a decrease in which of the following measurements?
1)Vital capacity
2)Total lung capacity
3)Forced expiratory flow from 25% to 75% of the vital capacity (FEF₂₅₋₇₅)
4)Ratio of forced expiratory volume in 1 second to vital capacity (FEV₁/VC)

A) 1 and 2
B) 2 and 3
C) 1 and 4
D) 3 and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
42
While working in the neonatal intensive care unit,a respiratory therapist notices that a baby with an apnea monitor is not breathing,but the apnea alarm is not ringing.Which of the following might cause this failure?
1)Tachypnea
2)Bradycardia
3)Excessive movement
4)Upper airway obstruction

A) 1 and 2
B) 2 and 4
C) 1 and 3
D) 3 and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
43
If a patient's minute volume is 8.5 L/min and his respiratory rate is 15 breaths/min,his average tidal volume is ____ L.

A) 0.125
B) 0.570
C) 0.060
D) 5.700
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
44
Total lung capacity is a result of:

A) vital capacity plus residual volume.
B) inspiratory capacity plus residual volume.
C) inspiratory capacity plus expiratory residual volume.
D) inspiratory reserve volume plus functional residual capacity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
45
What type of device is used in an ICU to detect respiratory muscle fatigue?

A) Aneroid manometer
B) Pressure plethysmograph
C) Inductive plethysmograph
D) Electromechanical transducer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
46
Which device would be appropriate for monitoring respiratory rate and tidal volume during a sleep study?

A) Capnograph
B) Mass spectrometer
C) Pneumotachograph
D) Inductive plethysmograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
47
Secretions in the airway of a mechanically ventilated patient could be indicated by a(n):

A) increase in inspiratory capacity.
B) increase in breathing frequency.
C) increase in peak inspiratory pressure.
D) decrease in forced expiratory flow rates.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
48
Which of the following devices can a patient with asthma use in the home to monitor daily variations in Raw?

A) Thermal flowmeter
B) Fleisch pneumotachograph
C) Screen pneumotachograph
D) Vortex ultrasonic flowmeter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
49
Which of the following values is not measured directly?

A) FEV₁
B) Airway resistance (Raw)
C) Peak expiratory flows
D) Maximum inspiratory pressure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
50
As measured by inductive plethysmography,rib cage movement plus abdominal movement equals:

A) tidal volume.
B) inspiratory capacity.
C) expiratory reserve volume.
D) functional residual capacity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
51
Newer ventilators can make tidal volume and minute volume measurements by incorporating which of the following?

A) Capnograph
B) Anemometer
C) Flow transducer
D) Pressure transducer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
52
To set up a pulmonary function laboratory that can measure all standard and dynamic lung volumes,which of the following equipment is necessary?

A) Screen pneumotachograph and inductive plethysmograph
B) Fleisch pneumotachograph and peak flowmeter
C) Vortex ultrasonic flowmeter and inductive plethysmograph
D) Stead-Wells spirometer and constant-volume plethysmograph
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
53
The results of pulmonary function testing show a normal total lung capacity and decreased,but reversible,FEV₁ and FEV₂₅₋₇₅.The patient is a 22-year-old,nonsmoking man with a history of intermittent "noisy breathing." Which of the following is most likely the cause of his problem?

A) Asthma
B) Emphysema
C) Pulmonary fibrosis
D) Severe restrictive pulmonary disease
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
54
The most appropriate lung volume to measure for a mechanically ventilated patient is _____ volume.

A) minute
B) residual
C) expiratory reserve
D) inspiratory reserve
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
55
Increased alveolar ventilation is associated with which of the following?

A) Hyperthermia
B) Bronchospasm
C) Decreased metabolic rate
D) Respiratory muscle fatigue
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
56
The principle that the respiratory system moves with 2 degrees of freedom describes the basis for which of the following?

A) Inductive plethysmography
B) Volume plethysmography
C) Strain gauge transducer
D) Nitrogen washout
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
57
Which of the following variables can be measured directly?

A) Lung compliance
B) Work of breathing
C) Raw
D) Pₚₗₐₜₑₐᵤ
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
58
Vital capacity is the sum of which of the following?
1)Residual volume
2)Inspiratory capacity
3)Expiratory reserve volume
4)Inspiratory reserve volume
5)Functional residual capacity

A) 2 and 3
B) 1 and 4
C) 2 and 5
D) 3 and 4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
59
Expiratory residual volume plus residual volume equals:

A) functional residual capacity.
B) inspiratory capacity.
C) total lung capacity.
D) vital capacity.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
60
What is the minute volume of a patient if her respiratory rate is 12 breaths/min and her tidal volume is 750 mL?

A) 0.06 L
B) 9.00 L
C) 6.25 L
D) 9.00 L
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
61
Which oxygen analyzer uses a semipermeable polytetrafluoroethylene membrane to separate oxygen from a potassium hydroxide bath containing a gold cathode and a lead anode?

A) Paramagnetic
B) Galvanic
C) Electrical
D) Polarographic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
62
Which device is appropriate for assessing a patient's response to bronchodilator therapy at the bedside?

A) Stead-Wells spirometer
B) Mainstream capnograph
C) Inductive plethysmograph
D) Rotating-vane flowmeter
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
63
Which of the following pathophysiologic conditions can increase both the peak inspiratory pressure and the Pₚₗₐₜₑₐᵤ of a ventilated patient?

A) Asthma
B) Atelectasis
C) Kyphoscoliosis
D) Pulmonary interstitial fibrosis
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
64
The respiratory system compliance of a patient receiving mechanical ventilation when the returned tidal volume is 650 mL,the static pressure is 35 cm H₂O,and the positive end-expiratory pressure is 8 cm H₂O is _____ mL/cm H₂O.

A) 0.04
B) 18.6
C) 53.9
D) 24
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
65
Which of the following variables in the formula describing Poiseuille's law can be altered in the clinical setting to improve Raw?
1)Radius of the airways
2)Viscosity of the inspired gas
3)Flow rate of the inspired gas
4)Temperature of the inspired gas
5)Length of the tracheobronchial tree

A) 1 and 3
B) 1,4,and 5
C) 2,3,and 5
D) 1,2,and 3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
66
The amount of pressure required by a ventilator to maintain tidal volume when there is no gas flow is known as:

A) Pₚₗₐₜₑₐᵤ.
B) peak inspiratory pressure.
C) peak expiratory pressure.
D) Maximum inspiratory pressure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
67
A(n)______ analyzer is an oxygen analyzer that uses paramagnetism to measure oxygen concentration.

A) Galvanic
B) Electrical
C) Paramagnetic
D) Polarographic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
68
Normal Raw of the respiratory system is _____ cm H₂O/L/s.

A) 1 to 3
B) 2 to 5
C) 4 to 8
D) 6 to 10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
69
Occlusion of the expiratory valve of the ventilator at the end of a tidal inspiration enables measurement of which of the following?

A) Pₚₗₐₜₑₐᵤ
B) Peak airway pressure
C) Maximum inspiratory pressure
D) Maximum expiratory pressure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
70
Which type of oxygen analyzer will give erroneous concentration levels in the presence of contaminant gases?

A) Polarographic
B) Electrical
C) Galvanic
D) Physical
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
71
The oxygen analyzer that is no longer commonly used is the ____ analyzer.

A) Paramagnetic
B) Galvanic
C) Electrical
D) Polarographic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
72
Electrical analyzers operate by using which of the following?

A) Clark electrodes
B) Pauling's principle
C) Thermal conductivity
D) Oxygen-mediated chemical reaction
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
73
What is the pressure reading on the anemometer of a ventilator during an inspiratory hold maneuver?

A) Pₚₗₐₜₑₐᵤ.
B) Peak inspiratory pressure
C) Mean inspiratory pressure
D) Maximum inspiratory pressure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
74
Which device can be incorporated into a ventilator to provide continuous recordings of airway pressure during the breathing cycle?

A) Variable capacitance transducer
B) Inductive plethysmograph
C) Strain gauge transducer
D) Aneroid manometer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
75
Which of the following happen to the wire within a Wheatstone bridge when it is exposed to oxygen concentrations higher than room air?
1)Its resistance decreases.
2)Its resistance increases.
3)It cools down.
4)It heats up.

A) 1 and 4
B) 2 and 3
C) 1 and 4
D) 1 and 3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
76
Which of the following is a complication of performing peak expiratory flows maneuvers?

A) Increased static pressure
B) Increased airway resistance
C) Decreased chest compliance
D) Decreased mean airway pressure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
77
A(n)______ analyzer is an oxygen analyzer that can display both partial pressure (in millimeters of mercury)and the percentage of oxygen concentration.

A) Paramagnetic
B) Galvanic
C) Electrical
D) Polarographic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
78
If the chest wall compliance of a mechanically ventilated patient decreases,which of the following will occur?

A) Maximum inspiratory pressure will decrease.
B) Peak inspiratory pressure will decrease.
C) Pₚₗₐₜₑₐᵤ will increase.
D) Tidal volume will increase.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
79
Which type of oxygen analyzer should not be used in the presence of anesthetic gases?

A) Polarographic
B) Paramagnetic
C) Electrical
D) Galvanic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
80
Which gas law is applicable when considering Raw?

A) Boyle's
B) Charles'
C) Poiseuille's
D) Avogadro's
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 120 في هذه المجموعة.