سؤال
A transmission line is protected by

A)inrush protection
B)distance protection
C)time graded and current graded over current protection
D)both (b) and (c)
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Large internal faults are protected by

A)merz price percentage differential protection
B)mho and ohm relays
C)horn gaps and temperature relays
D)earth fault and positive sequence relays
سؤال
When a transmission line is energized, the wave that propagates on it is

A)current wave only
B)voltage wave only
C)both (a) and (b)
D)power factor wave only
سؤال
Protective relays are devices that detect abnormal conditions in electrical circuits by measuring

A)current during abnormal condition
B)voltage during abnormal condition
C)constantly the electrical quantities which differ during normal and abnormal conditions
D)none of the above
سؤال
The voltage appearing across the contacts after opening of the circuit breaker is called______voltage.

A)recovery
B)surge
C)operating
D)arc
سؤال
Ionization in circuit breaker is facilitated by

A)high temperature
B)increase of mean free path
C)increasing field strength
D)all of the above
سؤال
In a circuit breaker the basic problem is to

A)maintain the arc
B)extinguish the arc
C)transmit large power
D)emit the ionizing electrons
سؤال
Overheating of relay contacts or contact born out is due to

A)slow making and breaking of load circuit contacts
B)foreign matter on the contact surface
C)too low contact pressure
D)all of the above
سؤال
Interruption of large currents by relay requires

A)arc suppressing blow out coils
B)wide separation of the opened contacts
C)high speed opening of contacts
D)all of the above
سؤال
Shunt capacitance is neglected while considering

A)short transmission line
B)medium transmission line
C)long transmission line
D)medium and long tr
سؤال
The arc voltage produced in A.C. circuit breaker is always

A)in phase with the arc current
B)lagging the arc current by 90?
C)leading the arc current by 90°
D)none of the above
سؤال
The time of closing the cycle, in modern circuit breakers is

A)0.003 sec
B)0.001 sec
C)0.01 sec
D)0.10 sec
سؤال
Insulation resistance of high voltage circuit breakers is more than

A)1 mega ohms
B)10 mega ohms
C)100 mega ohms
D)500 mega ohms
سؤال
H.R.C. fuses provide best protection against

A)overload
B)reverse current
C)open-circuits
D)short-circuits
سؤال
The ground wire should not be smaller than No ______ copper.

A)2
B)4
C)6
D)10
سؤال
The delay fuses are used for the protection of ________ .

A)motors
B)power outlet circuits
C)fluorescent lamps
D)light circuits
سؤال
Which of the following is the least expensive protection for overcurrent is low voltage system ?

A)Rewireable fuse
B)Isolator
C)Oil circuit breaker
D)Air break circuit breaker
سؤال
Resistance grounding is used for voltage between

A)33kVto66kV
B)HkVto33kV
C)3.3kVandllkV
D)none of the above
سؤال
The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to

A)lubricate the contacts
B)insulate the contacts from switch body
C)extinguish the arc
D)all of the above
سؤال
In Railway applications ______ circuit breaker is used.

A)SFe
B)bulk oil
C)minimum oil
D)air break
سؤال
To protect most of the electrical equipment handling low power, the types of relays used are

A)thermocouple
B)electronic and bimetallic
C)both (a) and (b)
D)none of the above
سؤال
Wave trap is used to trap waves of

A)power frequencies
B)higher frequencies entering generator or transformer units
C)either of the above
D)none of the above
سؤال
Ungrounded neutral transmission system is not recommended because of system

A)insulation being overstressed due to over voltages
B)insulation overstress may lead to failure and subsequent phase to phase faults
C)being inadequately protected against ground fault
D)all of the above
سؤال
The reflection co-efficient at the open circuited end of a transmission line.

A)zero
B)infinity
C)unity
D)none of the above
سؤال
For the protection of power station buildings against direct strokes the requirements are

A)interception
B)interception and conduction
C)interception, conduction and dissipation
D)interception, conduction, dissipation and reflection
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 2: Electrical Protection and Transmission Systems
1
A transmission line is protected by

A)inrush protection
B)distance protection
C)time graded and current graded over current protection
D)both (b) and (c)
both (b) and (c)
2
Large internal faults are protected by

A)merz price percentage differential protection
B)mho and ohm relays
C)horn gaps and temperature relays
D)earth fault and positive sequence relays
merz price percentage differential protection
3
When a transmission line is energized, the wave that propagates on it is

A)current wave only
B)voltage wave only
C)both (a) and (b)
D)power factor wave only
both (a) and (b)
4
Protective relays are devices that detect abnormal conditions in electrical circuits by measuring

A)current during abnormal condition
B)voltage during abnormal condition
C)constantly the electrical quantities which differ during normal and abnormal conditions
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
The voltage appearing across the contacts after opening of the circuit breaker is called______voltage.

A)recovery
B)surge
C)operating
D)arc
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
Ionization in circuit breaker is facilitated by

A)high temperature
B)increase of mean free path
C)increasing field strength
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
In a circuit breaker the basic problem is to

A)maintain the arc
B)extinguish the arc
C)transmit large power
D)emit the ionizing electrons
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
Overheating of relay contacts or contact born out is due to

A)slow making and breaking of load circuit contacts
B)foreign matter on the contact surface
C)too low contact pressure
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
Interruption of large currents by relay requires

A)arc suppressing blow out coils
B)wide separation of the opened contacts
C)high speed opening of contacts
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
Shunt capacitance is neglected while considering

A)short transmission line
B)medium transmission line
C)long transmission line
D)medium and long tr
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
The arc voltage produced in A.C. circuit breaker is always

A)in phase with the arc current
B)lagging the arc current by 90?
C)leading the arc current by 90°
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
The time of closing the cycle, in modern circuit breakers is

A)0.003 sec
B)0.001 sec
C)0.01 sec
D)0.10 sec
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
Insulation resistance of high voltage circuit breakers is more than

A)1 mega ohms
B)10 mega ohms
C)100 mega ohms
D)500 mega ohms
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
H.R.C. fuses provide best protection against

A)overload
B)reverse current
C)open-circuits
D)short-circuits
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
The ground wire should not be smaller than No ______ copper.

A)2
B)4
C)6
D)10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
The delay fuses are used for the protection of ________ .

A)motors
B)power outlet circuits
C)fluorescent lamps
D)light circuits
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
Which of the following is the least expensive protection for overcurrent is low voltage system ?

A)Rewireable fuse
B)Isolator
C)Oil circuit breaker
D)Air break circuit breaker
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
Resistance grounding is used for voltage between

A)33kVto66kV
B)HkVto33kV
C)3.3kVandllkV
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
The contacts of high voltage switches used in power system are submerged in oil. The main purpose of the oil is to

A)lubricate the contacts
B)insulate the contacts from switch body
C)extinguish the arc
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
In Railway applications ______ circuit breaker is used.

A)SFe
B)bulk oil
C)minimum oil
D)air break
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
To protect most of the electrical equipment handling low power, the types of relays used are

A)thermocouple
B)electronic and bimetallic
C)both (a) and (b)
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
Wave trap is used to trap waves of

A)power frequencies
B)higher frequencies entering generator or transformer units
C)either of the above
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
Ungrounded neutral transmission system is not recommended because of system

A)insulation being overstressed due to over voltages
B)insulation overstress may lead to failure and subsequent phase to phase faults
C)being inadequately protected against ground fault
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
The reflection co-efficient at the open circuited end of a transmission line.

A)zero
B)infinity
C)unity
D)none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
For the protection of power station buildings against direct strokes the requirements are

A)interception
B)interception and conduction
C)interception, conduction and dissipation
D)interception, conduction, dissipation and reflection