Deck 8: Electric Arc and Circuit Breaker Protection

ملء الشاشة (f)
exit full mode
سؤال
The heat produced at the contact point owing to flow of electric current is least affected by_____________________.

A)Temperature of the surrounding medium.
B)Contact resistance.
C)Magnitude of electric current flowing.
D)Duration of flow of current.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The resistance of an electric arc can be increased by

A)Increasing the concentration of ionised particles.
B)Reducing the arc length.
C)Splitting the arc
D)Increasing the arc cross section.
سؤال
By using low resistance method for arc extension what is the value of arc resistance?

A)Arc resistance is zero.
B)Arc resistance is high
C)Arc resistance is low
D)Arc resistance is very high
سؤال
What happens in the arc extinction using high resistance method?

A)Arc resistance is decreased with time.
B)Arc resistance is increased with time.
C)No change it remains same.
D)Arc resistance is kept zero.
سؤال
What is the arc voltage in a circuit breaker?

A)In phase with the arc current.
B)Lagging the arc current by 90°
C)Leading the arc current by 90°
D)Lagging the arcing current by 180°
سؤال
Arcing voltage will be the least in case of

A)Carbon
B)Copper
C)Silver
D)Tungsten
سؤال
How is the initiation of electric arc at the instant of contact separation caused?

A)Thermionic emission of electrons.
B)Field emission of electrons.
C)Both (a) and (b)
D)None of these.
سؤال
The arc resistance depends on which among the following factors?

A)Cross section of the arc
B)Length of the arc
C)Degree of ionization
D)All of the above.
سؤال
Which type of tripping is generally preferred for the circuit breaker?

A)Manual
B)Automatically
C)Depending on the voltage level
D)None of the above
سؤال
Which part of the circuit breaker is helpful in breaking the current?

A)Trip coil.
B)Contacts.
C)Medium
D)Handle.
سؤال
When a fault occurs in a high voltage transmission line, what happens first?

A)Circuit breaker operates then the relay.
B)Relay operates and then the circuit breaker.
C)Relay operates, then successively the isolator and the circuit breaker.
D)Isolator operates, then successively the relay and the circuit breaker.
سؤال
Upto what voltage can the liquid type HRC fuses be used?

A)33 kV
B)132 kV
C)66 kV
D)220 kV
سؤال
What is the main advantage of using a fuse?

A)Cheapest type of protection.
B)Inverse time current characteristics.
C)Current limiting effect under short circuit conditions.
D)All of above.
سؤال
On what basis is the selection of fuse done?

A)Steady load
B)Fluctuating load
C)Both (a) and (b)
D)None of these.
سؤال
Upto what voltage a cartridge type of fuse can be used?

A)400 V
B)11 kV
C)20 kV
D)33 kV
سؤال
In a HRC fuse what is the time between the cut off and the final current zero called?

A)Pre - arcing time.
B)Arcing time.
C)Total operating time.
D)None of these.
سؤال
Which material is used in the liquid type of fuse?

A)SF6
B)Distilled water
C)Carbon tetra chloride.
D)Mineral oil / transformer oil
سؤال
What is the advantage of HRC fuses over Rewirable fuses?

A)High speed operation
B)High rupturing capacity
C)No ageing effect.
D)All of the above.
سؤال
If the strands of the fusing wire are twisted, what happens to the fusing current?

A)Increases
B)Reduces.
C)No change/ remains same
D)Depends on the value of current, increases or decreases.
سؤال
What is the typical value of the pre arcing time?

A)0.1
B)0.01
C)0.001
D)0.0001
سؤال
Outdoor switchgear is generally used for voltage beyond

A)11 KV
B)33 KV
C)66 KV
D)132 KV
سؤال
The least expensive protection for over current in low-voltage system is

A)Rewirable fuse
B)Isolator
C)Circuit breaker
D)Air-break switch
سؤال
Purpose of backup protection is

A)To increase the speed
B)To increase a reach
C)To leave no blind spot
D)To guard against failure of primary
سؤال
We do not require any protection against prime mover failure in case of

A)Turbo generator sets
B)Hydro generator sets
C)Diesel engine driven alternators
D)Back pressure turbo generators
سؤال
For the protection of stator winding of an alternate against internal fault involving ground the relay used is a

A)Biased differential relay
B)Directional over-current relay
C)Plain impedance relay
D)Buchholz relay
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 8: Electric Arc and Circuit Breaker Protection
1
The heat produced at the contact point owing to flow of electric current is least affected by_____________________.

A)Temperature of the surrounding medium.
B)Contact resistance.
C)Magnitude of electric current flowing.
D)Duration of flow of current.
Temperature of the surrounding medium.
2
The resistance of an electric arc can be increased by

A)Increasing the concentration of ionised particles.
B)Reducing the arc length.
C)Splitting the arc
D)Increasing the arc cross section.
Splitting the arc
3
By using low resistance method for arc extension what is the value of arc resistance?

A)Arc resistance is zero.
B)Arc resistance is high
C)Arc resistance is low
D)Arc resistance is very high
Arc resistance is low
4
What happens in the arc extinction using high resistance method?

A)Arc resistance is decreased with time.
B)Arc resistance is increased with time.
C)No change it remains same.
D)Arc resistance is kept zero.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
What is the arc voltage in a circuit breaker?

A)In phase with the arc current.
B)Lagging the arc current by 90°
C)Leading the arc current by 90°
D)Lagging the arcing current by 180°
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
Arcing voltage will be the least in case of

A)Carbon
B)Copper
C)Silver
D)Tungsten
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
How is the initiation of electric arc at the instant of contact separation caused?

A)Thermionic emission of electrons.
B)Field emission of electrons.
C)Both (a) and (b)
D)None of these.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
The arc resistance depends on which among the following factors?

A)Cross section of the arc
B)Length of the arc
C)Degree of ionization
D)All of the above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
Which type of tripping is generally preferred for the circuit breaker?

A)Manual
B)Automatically
C)Depending on the voltage level
D)None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
Which part of the circuit breaker is helpful in breaking the current?

A)Trip coil.
B)Contacts.
C)Medium
D)Handle.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
When a fault occurs in a high voltage transmission line, what happens first?

A)Circuit breaker operates then the relay.
B)Relay operates and then the circuit breaker.
C)Relay operates, then successively the isolator and the circuit breaker.
D)Isolator operates, then successively the relay and the circuit breaker.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
Upto what voltage can the liquid type HRC fuses be used?

A)33 kV
B)132 kV
C)66 kV
D)220 kV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
What is the main advantage of using a fuse?

A)Cheapest type of protection.
B)Inverse time current characteristics.
C)Current limiting effect under short circuit conditions.
D)All of above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
On what basis is the selection of fuse done?

A)Steady load
B)Fluctuating load
C)Both (a) and (b)
D)None of these.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
Upto what voltage a cartridge type of fuse can be used?

A)400 V
B)11 kV
C)20 kV
D)33 kV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
In a HRC fuse what is the time between the cut off and the final current zero called?

A)Pre - arcing time.
B)Arcing time.
C)Total operating time.
D)None of these.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
Which material is used in the liquid type of fuse?

A)SF6
B)Distilled water
C)Carbon tetra chloride.
D)Mineral oil / transformer oil
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
What is the advantage of HRC fuses over Rewirable fuses?

A)High speed operation
B)High rupturing capacity
C)No ageing effect.
D)All of the above.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
If the strands of the fusing wire are twisted, what happens to the fusing current?

A)Increases
B)Reduces.
C)No change/ remains same
D)Depends on the value of current, increases or decreases.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
What is the typical value of the pre arcing time?

A)0.1
B)0.01
C)0.001
D)0.0001
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
Outdoor switchgear is generally used for voltage beyond

A)11 KV
B)33 KV
C)66 KV
D)132 KV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
The least expensive protection for over current in low-voltage system is

A)Rewirable fuse
B)Isolator
C)Circuit breaker
D)Air-break switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
Purpose of backup protection is

A)To increase the speed
B)To increase a reach
C)To leave no blind spot
D)To guard against failure of primary
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
We do not require any protection against prime mover failure in case of

A)Turbo generator sets
B)Hydro generator sets
C)Diesel engine driven alternators
D)Back pressure turbo generators
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
For the protection of stator winding of an alternate against internal fault involving ground the relay used is a

A)Biased differential relay
B)Directional over-current relay
C)Plain impedance relay
D)Buchholz relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.