Deck 10: Electrical Protection and Switchgear

ملء الشاشة (f)
exit full mode
سؤال
Large internal faults are protected by

A)Merz price percentage differential protection
B)Mho and ohm relays
C)Horan gaps and temperature relays
D)Earth fault and positive sequence relays
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Which of the following is the least expensive protection for over current in lowvoltage system ?

A)Rewireable fuse
B)Isolator
C)Oil circuit breaker
D)Air break circuit breaker
سؤال
For the protection of power station buildings against direct strokes the requirements are

A)Interception
B)Interception and conduction
C)Interception, conduction and dissipation
D)Interception,conduction,dissipation and reflection
سؤال
The line insulation is............. the insulation level at the station equipment

A)Less than
B)Same as
C)More than
D)Not directly related with
سؤال
Short-circuit currents are due to

A)Single phase to ground faults
B)Phase to phase faults
C)Three phase faults
D)Any of these
سؤال
For which of the following protection from negative sequence current is provided?

A)Generators
B)Motors
C)Transmission line
D)Transformers
سؤال
For which of the following ratings of the transformer differential protection is recommended?

A)Above 30 KVA
B)Equal to and above 5 MVA
C)Equal two and above 25 MVA
D)None of the above
سؤال
Over voltage protection is recommended for

A)Hydro electric generators
B)Steam turbine generators
C)Gasturbine generators
D)All of the above
سؤال
Overfluxing protection is recommended for

A)Distribution transformer
B)Generator transformer of the power plant
C)Auto transformer of the power plant
D)Station transformer of the power plant
سؤال
Hey switchgear is device used for

A)Interrupting an electrical circuit
B)Switching an electrical circuit
C)Reaching and controlling an electrical circuit
D)Switching, controlling and protecting the electrical circuit and equipment
سؤال
Switching over voltage arc are more hazardous than lighting surges in case of

A)Unbalanced systems
B)Low-voltages
C)11 KV systems
D)EHV and UHV systems
سؤال
Least number of faults are generally reported for

A)Transmission lines
B)Cables
C)Switchgears
D)Transformers
سؤال
Minimum working voltage will be least in case of

A)Silver
B)Graphite
C)Carbon
D)Tungsten
سؤال
In a contactor, interrupting medium may be

A)Air
B)Oil
C)Sf6 gas
D)Any of the above
سؤال
The transient voltages that appears across the contacts at the instant of arc extinction is called ..............voltage

A)Supply
B)Recovery
C)Restriking
D)Peak
سؤال
The power loss is an important factor for the design of

A)Transmission line
B)Motor
C)Generator
D)Feeder
سؤال
SF6 gas

A)Is yellow in colour
B)Is lighter than air
C)Is non-toxic
D)Has pungent small
سؤال
SF6 gas is transported in

A)Air cylinders
B)Gas cylinders
C)Liquid from in cylinders
D)Solid form in boxes
سؤال
The short-circuit in any winding of the transformer is the result of

A)Mechanical vibration
B)Insulation failure
C)Loose connection
D)Impulse voltage
سؤال
The actuating quantity for the relays may be

A)Magnitude
B)Frequency
C)Phase angle
D)Any of the above
سؤال
The operating speed of a relay depends upon the

A)Rate of flux built up
B)Armature core air gap
C)Spring tension
D)All of these
سؤال
Inverse time current relays are used for the protection of

A)Feeders
B)Transformers
C)Alternators
D)Both A and B
سؤال
IDMT relays are used to protect the power transformers against

A)External short-circuit
B)Over loads
C)Internal short-circuits
D)Both A and B
سؤال
In distance protection, the relay measures

A)Negative sequence impedance of the light from relay up to the fault point
B)Positive sequence impedance of the line from relay up to the fault point
C)Self impedance of the line from relay up to the fault point
D)Zero sequence impedance of the line from relay up to the fault point
سؤال
The relay used for phase fault protection of short transmission lines is

A)Reactance relay
B)Impedance relay
C)Mho relay
D)IDMT relay
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 10: Electrical Protection and Switchgear
1
Large internal faults are protected by

A)Merz price percentage differential protection
B)Mho and ohm relays
C)Horan gaps and temperature relays
D)Earth fault and positive sequence relays
Merz price percentage differential protection
2
Which of the following is the least expensive protection for over current in lowvoltage system ?

A)Rewireable fuse
B)Isolator
C)Oil circuit breaker
D)Air break circuit breaker
Rewireable fuse
3
For the protection of power station buildings against direct strokes the requirements are

A)Interception
B)Interception and conduction
C)Interception, conduction and dissipation
D)Interception,conduction,dissipation and reflection
Interception, conduction and dissipation
4
The line insulation is............. the insulation level at the station equipment

A)Less than
B)Same as
C)More than
D)Not directly related with
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
Short-circuit currents are due to

A)Single phase to ground faults
B)Phase to phase faults
C)Three phase faults
D)Any of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
For which of the following protection from negative sequence current is provided?

A)Generators
B)Motors
C)Transmission line
D)Transformers
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
For which of the following ratings of the transformer differential protection is recommended?

A)Above 30 KVA
B)Equal to and above 5 MVA
C)Equal two and above 25 MVA
D)None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
Over voltage protection is recommended for

A)Hydro electric generators
B)Steam turbine generators
C)Gasturbine generators
D)All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
Overfluxing protection is recommended for

A)Distribution transformer
B)Generator transformer of the power plant
C)Auto transformer of the power plant
D)Station transformer of the power plant
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
Hey switchgear is device used for

A)Interrupting an electrical circuit
B)Switching an electrical circuit
C)Reaching and controlling an electrical circuit
D)Switching, controlling and protecting the electrical circuit and equipment
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
Switching over voltage arc are more hazardous than lighting surges in case of

A)Unbalanced systems
B)Low-voltages
C)11 KV systems
D)EHV and UHV systems
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
Least number of faults are generally reported for

A)Transmission lines
B)Cables
C)Switchgears
D)Transformers
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
Minimum working voltage will be least in case of

A)Silver
B)Graphite
C)Carbon
D)Tungsten
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
In a contactor, interrupting medium may be

A)Air
B)Oil
C)Sf6 gas
D)Any of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
The transient voltages that appears across the contacts at the instant of arc extinction is called ..............voltage

A)Supply
B)Recovery
C)Restriking
D)Peak
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
The power loss is an important factor for the design of

A)Transmission line
B)Motor
C)Generator
D)Feeder
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
SF6 gas

A)Is yellow in colour
B)Is lighter than air
C)Is non-toxic
D)Has pungent small
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
SF6 gas is transported in

A)Air cylinders
B)Gas cylinders
C)Liquid from in cylinders
D)Solid form in boxes
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
The short-circuit in any winding of the transformer is the result of

A)Mechanical vibration
B)Insulation failure
C)Loose connection
D)Impulse voltage
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
The actuating quantity for the relays may be

A)Magnitude
B)Frequency
C)Phase angle
D)Any of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
The operating speed of a relay depends upon the

A)Rate of flux built up
B)Armature core air gap
C)Spring tension
D)All of these
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
Inverse time current relays are used for the protection of

A)Feeders
B)Transformers
C)Alternators
D)Both A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
IDMT relays are used to protect the power transformers against

A)External short-circuit
B)Over loads
C)Internal short-circuits
D)Both A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
In distance protection, the relay measures

A)Negative sequence impedance of the light from relay up to the fault point
B)Positive sequence impedance of the line from relay up to the fault point
C)Self impedance of the line from relay up to the fault point
D)Zero sequence impedance of the line from relay up to the fault point
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
The relay used for phase fault protection of short transmission lines is

A)Reactance relay
B)Impedance relay
C)Mho relay
D)IDMT relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.