Deck 11: Relaying Schemes and Techniques for Electrical Equipment Protection

ملء الشاشة (f)
exit full mode
سؤال
Where severe synchronising swing occur, the relay employed is

A)Impedance relay
B)Mho relay
C)Reactance relay
D)Induction relay
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
For the protection of lines against faults involving variable fault resistance, the preferred relaying scheme is a

A)Plain impedance relay
B)Directional over-current relay
C)Mho relay
D)Reactance relay
سؤال
For ground fault we prefer

A)Plain impedance relay
B)Directional over current relay
C)Mho relay
D)Reactance relay
سؤال
Admittance relay

A)Nondirectional relay
B)Directional relay
C)Differential relay
D)None of the above
سؤال
The relay used for feeder protection is

A)Under voltage relay
B)Translay relay
C)Thermal relay
D)Buchholz relay
سؤال
Which relay is used to detect and protect internal fault in a transformer ?

A)Buchholz relay
B)Directional relay
C)Thermal relay
D)Distance relay
سؤال
Which one of the following relay has the capability of anticipating the possible major fault in a transformer ?

A)Over-current relay
B)Differential relay
C)Buchholz relay
D)Over fluxing relay
سؤال
Zero sequence current is used for relaying purpose only in the case of

A)Phase over current really
B)Phase impedance relay
C)Ground over current relay
D)Ground impedance relay
سؤال
To prevent mal operation of differentially connected relay while energising a transformer, the relay restraining coil is biased with

A)Second harmonic current
B)Third harmonic current
C)Fifth harmonic current
D)Seventh harmonic current
سؤال
How many relays are used to detect interphase fault of a three line system?

A)One
B)Two
C)Three
D)Six
سؤال
Which is the main relay for protecting up to 90% of the transmission line-length in the forward direction?

A)Directional over current relay
B)Mho relay
C)Carrier current protective relay
D)Impedance relay
سؤال
For protection of parallel feeders fed from one end, the relays required are

A)Nondirectional relays at the source end and directional relay at the load end
B)Nondirectional relay at both ends
C)Directional relay at source end and nondirectional relay at load end
D)Directional relay at both ends
سؤال
Relays can be designed to respond to changes in

A)Resistance, reactance or impedance
B)Voltage and current
C)Light intensity
D)All of the above
سؤال
DC shunt relays are made of

A)Few turns of thin wire
B)Few turns of thick wire
C)Many turns of thin wire
D)Many turns of thick wire
سؤال
In order that current should flow without causing excessive heating or voltage drop, the relay contacts should

A)Have low contact resistance
B)Be clean and smooth
C)Be of sufficient size and proper shape
D)Have all above properties
سؤال
Interruption of large currents by relay requires

A)Arc suppressing blow out coils
B)Wide separation of the open contacts
C)High speed opening of contacts
D)All of the above
سؤال
To protect most of the electrical equipment handling low power, the types of relays used are

A)Thermocouple
B)Electronic and bimetallic
C)Both A and B
D)None of the above
سؤال
............. Relays are used for phase faults on long line

A)Impedance
B)Reactance
C)Either of the above
D)None of the above
سؤال
........ Relays is preferred for phase fault on short transmission line

A)Induction type
B)Reactance
C)Impedance
D)None of the above
سؤال
The under voltage relay can be used for

A)Generators
B)Bus bars
C)Transformers
D)All of the above
سؤال
The single phasing relays are used for the protection of

A)Single phase motors only
B)Two phase motors only
C)Two single phase motor running in parallel
D)Three phase motors
سؤال
The inverse definite mean time relays are used for over current and earth fault protection of transformer against

A)Heavy loads
B)Internal short circuits
C)External short circuits
D)All of the above
سؤال
In a static over current relay, inverse time characteristics are obtained by

A)A transistor amplifier
B)An integrating circuit
C)A transistor switch
D)A differentiating circuit
سؤال
In the case of transmission line protection, over current relay is used

A)Only up to 110 KV
B)Only up to 220 KV
C)Only up to 50 KV
D)Only up to 1100 KV
سؤال
Directional over current relays have two exciting coils connected across

A)CT secondaries of two different phases
B)VT secondaries of two different phases
C)CT and VT secondaries of same phases
D)CT and VT secondaries of two different phases
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 11: Relaying Schemes and Techniques for Electrical Equipment Protection
1
Where severe synchronising swing occur, the relay employed is

A)Impedance relay
B)Mho relay
C)Reactance relay
D)Induction relay
Mho relay
2
For the protection of lines against faults involving variable fault resistance, the preferred relaying scheme is a

A)Plain impedance relay
B)Directional over-current relay
C)Mho relay
D)Reactance relay
Reactance relay
3
For ground fault we prefer

A)Plain impedance relay
B)Directional over current relay
C)Mho relay
D)Reactance relay
Reactance relay
4
Admittance relay

A)Nondirectional relay
B)Directional relay
C)Differential relay
D)None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
The relay used for feeder protection is

A)Under voltage relay
B)Translay relay
C)Thermal relay
D)Buchholz relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
Which relay is used to detect and protect internal fault in a transformer ?

A)Buchholz relay
B)Directional relay
C)Thermal relay
D)Distance relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which one of the following relay has the capability of anticipating the possible major fault in a transformer ?

A)Over-current relay
B)Differential relay
C)Buchholz relay
D)Over fluxing relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
Zero sequence current is used for relaying purpose only in the case of

A)Phase over current really
B)Phase impedance relay
C)Ground over current relay
D)Ground impedance relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
To prevent mal operation of differentially connected relay while energising a transformer, the relay restraining coil is biased with

A)Second harmonic current
B)Third harmonic current
C)Fifth harmonic current
D)Seventh harmonic current
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
How many relays are used to detect interphase fault of a three line system?

A)One
B)Two
C)Three
D)Six
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
Which is the main relay for protecting up to 90% of the transmission line-length in the forward direction?

A)Directional over current relay
B)Mho relay
C)Carrier current protective relay
D)Impedance relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
For protection of parallel feeders fed from one end, the relays required are

A)Nondirectional relays at the source end and directional relay at the load end
B)Nondirectional relay at both ends
C)Directional relay at source end and nondirectional relay at load end
D)Directional relay at both ends
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
Relays can be designed to respond to changes in

A)Resistance, reactance or impedance
B)Voltage and current
C)Light intensity
D)All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
DC shunt relays are made of

A)Few turns of thin wire
B)Few turns of thick wire
C)Many turns of thin wire
D)Many turns of thick wire
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
In order that current should flow without causing excessive heating or voltage drop, the relay contacts should

A)Have low contact resistance
B)Be clean and smooth
C)Be of sufficient size and proper shape
D)Have all above properties
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
Interruption of large currents by relay requires

A)Arc suppressing blow out coils
B)Wide separation of the open contacts
C)High speed opening of contacts
D)All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
To protect most of the electrical equipment handling low power, the types of relays used are

A)Thermocouple
B)Electronic and bimetallic
C)Both A and B
D)None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
............. Relays are used for phase faults on long line

A)Impedance
B)Reactance
C)Either of the above
D)None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
........ Relays is preferred for phase fault on short transmission line

A)Induction type
B)Reactance
C)Impedance
D)None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
The under voltage relay can be used for

A)Generators
B)Bus bars
C)Transformers
D)All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
The single phasing relays are used for the protection of

A)Single phase motors only
B)Two phase motors only
C)Two single phase motor running in parallel
D)Three phase motors
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
The inverse definite mean time relays are used for over current and earth fault protection of transformer against

A)Heavy loads
B)Internal short circuits
C)External short circuits
D)All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
In a static over current relay, inverse time characteristics are obtained by

A)A transistor amplifier
B)An integrating circuit
C)A transistor switch
D)A differentiating circuit
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
In the case of transmission line protection, over current relay is used

A)Only up to 110 KV
B)Only up to 220 KV
C)Only up to 50 KV
D)Only up to 1100 KV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
Directional over current relays have two exciting coils connected across

A)CT secondaries of two different phases
B)VT secondaries of two different phases
C)CT and VT secondaries of same phases
D)CT and VT secondaries of two different phases
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.