Deck 3: Classification of Mechanical Ventilators

ملء الشاشة (f)
exit full mode
سؤال
The type of drive mechanism determines the characteristic flow and pressure patterns each ventilator produces.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A negative pressure ventilator applies pressure inside the chest to expand it.
سؤال
Flow triggering has been shown to be more sensitive and responsive to a patient's efforts than pressure triggering.
سؤال
During dual control within breath modes, the ventilator switches from pressure-controlled to flow-controlled.
سؤال
Output waveforms are typically presented in the order of pressure, volume, and flow.
سؤال
____ is a unit of volume divided by a unit of time.

A) Flow
B) Compliance
C) Resistance
D) Pressure
سؤال
Which of the following is an example of an electrically powered ventilator?

A) Bird Mark 7
B) Percussionaire IPV
C) CareFusion LTV 1150
D) Monaghan 225/SIMV
سؤال
The ____ is the system that governs or controls the ventilator drive mechanism or output control valve.

A) solenoid valve
B) control circuit
C) compressor
D) piston
سؤال
Which of the following types of control circuits may also be referred to as servo controlled?

A) open loop
B) closed loop
C) mechanical
D) electronic
سؤال
____ are ventilators that measure and control inspiratory and expiratory time.

A) Flow controllers
B) Volume controllers
C) Pressure controllers
D) Time controllers
سؤال
A ____ breath is initiated and delivered by the ventilator when it senses the patient's spontaneous inspiratory effort.

A) time-triggered
B) pressure-triggered
C) volume-triggered
D) flow-triggered
سؤال
The variable that is controlled during the expiratory phase or expiratory time is termed the ____.

A) limit variable
B) baseline variable
C) cycle variable
D) conditional variable
سؤال
____ is a time-triggered, pressure-limited and time cycled mode that allows for spontaneous breathing.

A) Intermittent mandatory ventilation (IMV)
B) Automode
C) Proportional assist ventilation (PAV)
D) Airway pressure release ventilation (APRV)
سؤال
Which of the following waveforms are characteristically produced by ventilators having a rotary-driven piston drive mechanism?

A) rectangular
B) exponential
C) sinusoidal
D) oscillating
سؤال
Which of the following flow waveforms is produced when volume is the control variable and the output is an ascending ramp?

A) rectangular
B) ascending ramp
C) descending ramp
D) sinusoidal
سؤال
Flow alarms are limited to ____.

A) exhaled minute volume
B) gas temperature
C) oxygen concentration
D) total ventilatory frequency
سؤال
____ alarms alert the clinician to changes in oxygen concentration or gas temperature.

A) Expiratory gas
B) Volume
C) Inspiratory gas
D) Time
سؤال
____ is defined as a change in volume divided by a change in pressure.

A) Flow
B) Compliance
C) Resistance
D) Pressure
سؤال
A resistance load is proportional to ____.

A) volume
B) compliance
C) volume and airway resistance
D) airway resistance and inspiratory flow
سؤال
_______________ proposed a new way to classify mechanical ventilators based on related features, physics, and engineering.
سؤال
Current generation ventilators use programmed algorithms in the microprocessors to open and close the _______________ to mimic virtually any flow or pressure wave pattern.
سؤال
_______________ is defined as the time interval between the start of inspiratory flow and the beginning of expiratory flow.
سؤال
Automatic tube compensation is active both during inspiration and expiration, and may reduce air trapping and _______________.
سؤال
_______________ alert the clinician to settings or parameters that are not within acceptable ranges or specifications, or they warn the clinician that the ventilator has failed some part of a self-diagnostic test.
سؤال
Describe inspiration and expiration.
سؤال
Explain the advantage of both pressure-controlled ventilation and volume-controlled ventilation.
سؤال
Discuss how careful observation and assessment of waveforms during mechanical ventilation can provide useful information for the clinician.
سؤال
Discuss Robert Chatburn's ventilator classification system.
سؤال
Describe the four types of flow waveforms.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/29
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 3: Classification of Mechanical Ventilators
1
The type of drive mechanism determines the characteristic flow and pressure patterns each ventilator produces.
True
2
A negative pressure ventilator applies pressure inside the chest to expand it.
False
3
Flow triggering has been shown to be more sensitive and responsive to a patient's efforts than pressure triggering.
True
4
During dual control within breath modes, the ventilator switches from pressure-controlled to flow-controlled.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
5
Output waveforms are typically presented in the order of pressure, volume, and flow.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
6
____ is a unit of volume divided by a unit of time.

A) Flow
B) Compliance
C) Resistance
D) Pressure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
7
Which of the following is an example of an electrically powered ventilator?

A) Bird Mark 7
B) Percussionaire IPV
C) CareFusion LTV 1150
D) Monaghan 225/SIMV
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
8
The ____ is the system that governs or controls the ventilator drive mechanism or output control valve.

A) solenoid valve
B) control circuit
C) compressor
D) piston
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
9
Which of the following types of control circuits may also be referred to as servo controlled?

A) open loop
B) closed loop
C) mechanical
D) electronic
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
10
____ are ventilators that measure and control inspiratory and expiratory time.

A) Flow controllers
B) Volume controllers
C) Pressure controllers
D) Time controllers
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
11
A ____ breath is initiated and delivered by the ventilator when it senses the patient's spontaneous inspiratory effort.

A) time-triggered
B) pressure-triggered
C) volume-triggered
D) flow-triggered
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
12
The variable that is controlled during the expiratory phase or expiratory time is termed the ____.

A) limit variable
B) baseline variable
C) cycle variable
D) conditional variable
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
13
____ is a time-triggered, pressure-limited and time cycled mode that allows for spontaneous breathing.

A) Intermittent mandatory ventilation (IMV)
B) Automode
C) Proportional assist ventilation (PAV)
D) Airway pressure release ventilation (APRV)
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
14
Which of the following waveforms are characteristically produced by ventilators having a rotary-driven piston drive mechanism?

A) rectangular
B) exponential
C) sinusoidal
D) oscillating
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
15
Which of the following flow waveforms is produced when volume is the control variable and the output is an ascending ramp?

A) rectangular
B) ascending ramp
C) descending ramp
D) sinusoidal
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
16
Flow alarms are limited to ____.

A) exhaled minute volume
B) gas temperature
C) oxygen concentration
D) total ventilatory frequency
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
17
____ alarms alert the clinician to changes in oxygen concentration or gas temperature.

A) Expiratory gas
B) Volume
C) Inspiratory gas
D) Time
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
18
____ is defined as a change in volume divided by a change in pressure.

A) Flow
B) Compliance
C) Resistance
D) Pressure
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
19
A resistance load is proportional to ____.

A) volume
B) compliance
C) volume and airway resistance
D) airway resistance and inspiratory flow
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
20
_______________ proposed a new way to classify mechanical ventilators based on related features, physics, and engineering.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
21
Current generation ventilators use programmed algorithms in the microprocessors to open and close the _______________ to mimic virtually any flow or pressure wave pattern.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
22
_______________ is defined as the time interval between the start of inspiratory flow and the beginning of expiratory flow.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
23
Automatic tube compensation is active both during inspiration and expiration, and may reduce air trapping and _______________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
24
_______________ alert the clinician to settings or parameters that are not within acceptable ranges or specifications, or they warn the clinician that the ventilator has failed some part of a self-diagnostic test.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
25
Describe inspiration and expiration.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
26
Explain the advantage of both pressure-controlled ventilation and volume-controlled ventilation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
27
Discuss how careful observation and assessment of waveforms during mechanical ventilation can provide useful information for the clinician.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
28
Discuss Robert Chatburn's ventilator classification system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
29
Describe the four types of flow waveforms.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 29 في هذه المجموعة.