Deck 64: Heating and Air-Conditioning System Diagnosis

ملء الشاشة (f)
exit full mode
سؤال
A customer complains that the heater works sometimes, but sometimes only cold air comes out while Driving. Technician A says that the water pump is defective. Technician B says that the cooling system could be low on coolant. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Airflow through a typical HVAC system is being discussed. Technician A says that outside air is always used in all heating and cooling positions. Technician B says that the temperature is controlled by blending airflow through the evaporator and heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
The first step in the diagnostic procedure when attempting to solve an HVAC customer problem is ________.

A)Check for technical service bulletins
B)Visual inspection
C)Check for diagnostic trouble codes
D)Verify customer concern
سؤال
The last step in the diagnostic procedure is ________.

A)Recharge the system
B)Determine the root cause
C)Perform a visual inspection
D)Verify the repair
سؤال
Technician A says that one heater hose should be hot and the other hose cool if the heater is functioning okay. Technician B says that both hoses should be hot to the touch. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Nothing is seen in the sight glass (R-12 system). Technician A says that the system may be completely empty of refrigerant. Technician B says that the system may be completely charged. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Technician A says that evaporator leaks can be detected by installing dye into the system and looking for yellowish-green dye stains. Technician B says that a leak at the evaporator can be detected by removing the blower motor resistor pack and inserting an electronic leak detector probe into the air stream. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Technician A says that with a properly operating air-conditioning system, the inlet to the compressor should be cold and the outlet from the compressor hot. Technician B says that the condenser should be hot and the evaporator cold. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
A clogged orifice tube can cause a lack of cooling.
سؤال
What must the technician do before checking an air conditioning system for refrigerant leaks using a black light?

A)Turn the system off and allow the pressure to equalize
B)Overcharge the system by 10 oz.
C)Evacuate the system
D)Install dye in the system
سؤال
Technician A says heater temperature may be controlled by regulating the amount of coolant flowing Through the heater core. Technician B says heater temperature may be controlled by regulating the amount of air flowing through the heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Technician A says a thermostat which opens too soon can cause poor heater operation. Technician B says low coolant level can cause poor heater operation. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Technician A says AC system lines and hoses that are cold have lower refrigerant pressure than warmer lines and hoses. Technician B says frost on a system component usually indicates a refrigerant leak in that area. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Technician A says oily residue on hoses, components, or fittings indicates an area where refrigerant may be leaking. Technician B says damaged condenser fins may cause inefficient air conditioning operation at all blower speeds. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
The outlet line from the evaporator should be ________.

A)Frost-covered
B)Cool
C)Warm
D)Hot
سؤال
Technician A says electronic leak detectors make a noise when a leak is detected. Technician B says that often the same leak detector can be used for R-12 and R 134a. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
Technician A says refrigerant leaks are most common where components join together. Technician B says many manufacturers put leak-tracing dye in the refrigerant systems of new vehicles. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
An air conditioning performance check requires a ________.

A)Thermometer and a vacuum pump
B)Thermometer and a manifold gauge set
C)Manifold gauge set and a volt-ohmmeter
D)Thermometer and a hydrometer
سؤال
If both the low side and the high side show low readings, what might be the problem?

A)Condenser malfunction
B)Cooling fan malfunction
C)Low refrigerant charge
D)TXV stuck open
سؤال
Technician A checks ambient temperature as part of an AC performance test. Technician B says that if the AC compressor has not been operating, the high side and low side refrigerant pressure should be equal. Who is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
سؤال
If the performance test shows less than 45° F at the center vent, the AC is working normally.
سؤال
On a cold day it is normal for the thermostat to stay closed for more than 15 minutes.
سؤال
An AC system has had about 0.5 lbs of R-22 refrigerant added. What would this cause?

A)Low high side pressures
B)Very high high side pressures
C)No problems, normal AC cooling
D)Increased cooling
سؤال
The ambient temperature is 70° F and the humidity is low. What should the high side gauge pressure be (AC system on)?

A)140 to 190 psi
B)300 to 350 psi
C)10 to 50 psi
D)Not enough information to tell
سؤال
It is 90°F in the shop and the humidity is high. What pressure will be shown on the high side pressure gauge (AC system on)?

A)10 to 50 psi
B)At least 350 psi
C)210 to 290 psi
D)40 to 140 psi
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 64: Heating and Air-Conditioning System Diagnosis
1
A customer complains that the heater works sometimes, but sometimes only cold air comes out while Driving. Technician A says that the water pump is defective. Technician B says that the cooling system could be low on coolant. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Technician B only
2
Airflow through a typical HVAC system is being discussed. Technician A says that outside air is always used in all heating and cooling positions. Technician B says that the temperature is controlled by blending airflow through the evaporator and heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
Technician B only
3
The first step in the diagnostic procedure when attempting to solve an HVAC customer problem is ________.

A)Check for technical service bulletins
B)Visual inspection
C)Check for diagnostic trouble codes
D)Verify customer concern
Verify customer concern
4
The last step in the diagnostic procedure is ________.

A)Recharge the system
B)Determine the root cause
C)Perform a visual inspection
D)Verify the repair
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
Technician A says that one heater hose should be hot and the other hose cool if the heater is functioning okay. Technician B says that both hoses should be hot to the touch. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
Nothing is seen in the sight glass (R-12 system). Technician A says that the system may be completely empty of refrigerant. Technician B says that the system may be completely charged. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
Technician A says that evaporator leaks can be detected by installing dye into the system and looking for yellowish-green dye stains. Technician B says that a leak at the evaporator can be detected by removing the blower motor resistor pack and inserting an electronic leak detector probe into the air stream. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
Technician A says that with a properly operating air-conditioning system, the inlet to the compressor should be cold and the outlet from the compressor hot. Technician B says that the condenser should be hot and the evaporator cold. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
A clogged orifice tube can cause a lack of cooling.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
What must the technician do before checking an air conditioning system for refrigerant leaks using a black light?

A)Turn the system off and allow the pressure to equalize
B)Overcharge the system by 10 oz.
C)Evacuate the system
D)Install dye in the system
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
Technician A says heater temperature may be controlled by regulating the amount of coolant flowing Through the heater core. Technician B says heater temperature may be controlled by regulating the amount of air flowing through the heater core. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
Technician A says a thermostat which opens too soon can cause poor heater operation. Technician B says low coolant level can cause poor heater operation. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
Technician A says AC system lines and hoses that are cold have lower refrigerant pressure than warmer lines and hoses. Technician B says frost on a system component usually indicates a refrigerant leak in that area. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
Technician A says oily residue on hoses, components, or fittings indicates an area where refrigerant may be leaking. Technician B says damaged condenser fins may cause inefficient air conditioning operation at all blower speeds. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
The outlet line from the evaporator should be ________.

A)Frost-covered
B)Cool
C)Warm
D)Hot
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
Technician A says electronic leak detectors make a noise when a leak is detected. Technician B says that often the same leak detector can be used for R-12 and R 134a. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
Technician A says refrigerant leaks are most common where components join together. Technician B says many manufacturers put leak-tracing dye in the refrigerant systems of new vehicles. Which technician is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
An air conditioning performance check requires a ________.

A)Thermometer and a vacuum pump
B)Thermometer and a manifold gauge set
C)Manifold gauge set and a volt-ohmmeter
D)Thermometer and a hydrometer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
If both the low side and the high side show low readings, what might be the problem?

A)Condenser malfunction
B)Cooling fan malfunction
C)Low refrigerant charge
D)TXV stuck open
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
Technician A checks ambient temperature as part of an AC performance test. Technician B says that if the AC compressor has not been operating, the high side and low side refrigerant pressure should be equal. Who is correct?

A)Technician A only
B)Technician B only
C)Both technicians A and B
D)Neither technician A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
If the performance test shows less than 45° F at the center vent, the AC is working normally.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
On a cold day it is normal for the thermostat to stay closed for more than 15 minutes.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
An AC system has had about 0.5 lbs of R-22 refrigerant added. What would this cause?

A)Low high side pressures
B)Very high high side pressures
C)No problems, normal AC cooling
D)Increased cooling
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
The ambient temperature is 70° F and the humidity is low. What should the high side gauge pressure be (AC system on)?

A)140 to 190 psi
B)300 to 350 psi
C)10 to 50 psi
D)Not enough information to tell
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
It is 90°F in the shop and the humidity is high. What pressure will be shown on the high side pressure gauge (AC system on)?

A)10 to 50 psi
B)At least 350 psi
C)210 to 290 psi
D)40 to 140 psi
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.