Restriction of the primary beam to the anatomy of interest:

A) reduces patient exposure
B) is a major cause of repeated images
C) reduces the amount of scatter produced
D) A and C
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The probability of a Compton interaction occurring is related to:

A) the energy of the x-ray photon
B) the atomic number of the matter
C) the mAs used
D) all of the above
سؤال
When imaging the pelvis,changing from 14 × 17 collimation to 8 × 10 collimation requires:

A) an increase in kVp
B) a decrease in kVp
C) an increase in mAs
D) a decrease in mAs
سؤال
The most effective and often used radiographic beam-restriction device is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
سؤال
The flat piece of lead with a hole in it is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
سؤال
The most easily adjusted radiographic beam-restricting device is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
سؤال
The beam-restriction device that includes a visible light projecting the x-ray field size onto the patient is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
سؤال
The field shape produced by a collimator is:

A) round
B) oval
C) rectangular
D) all of the above
سؤال
As compared with lower kVp exposures,when using high kVp the energy of the scattered photon is:

A) lower
B) higher
C) the same
D) half
سؤال
A flat piece of lead with a hole in it that has a flange directed toward the patient is a(n):

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
سؤال
Decreasing collimation (opening up the field size)results in:

A) increased scatter production and higher contrast
B) increased scatter production and lower contrast
C) decreased scatter production and higher contrast
D) decreased scatter production and lower contrast
سؤال
The volume of tissue irradiated is determined by:

A) the area of collimation
B) patient thickness
C) field size
D) all of the above
سؤال
The beam-restriction device that results in images with the most unsharpness around the edge of the image is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
سؤال
_____________________ collimation means _________________ field size.

A) decreasing;increasing
B) increasing;increasing
C) decreasing;decreasing
D) none of the above
سؤال
For radiographic procedures,scatter radiation is primarily the result of:

A) photoelectric interaction
B) pair production
C) Compton interaction
D) classical scattering
سؤال
When there is significant collimation,the amount of radiation reaching the IR is:

A) reduced
B) increased
C) the same
D) none of the above
سؤال
The automatic collimator:

A) automatically collimates to the anatomy of interest
B) is required by law on all new equipment
C) is seldom found on modern x-ray equipment
D) automatically collimates to the IR size
سؤال
The two major factors that affect the amount of scatter radiation produced and exiting the patient are:

A) kVp and mAs
B) volume of tissue irradiated and mAs
C) volume of tissue irradiated and kVp
D) kVp and the use of a grid
سؤال
The unrestricted primary x-ray beam is:

A) round
B) oval
C) square
D) rectangular
سؤال
Which of the following produces the greatest amount of scatter radiation exiting the patient?

A) low kVp and small field size
B) low kVp and large field size
C) high kVp and small field size
D) high kVp and large field size
سؤال
The higher the grid ratio,the _____________ the scatter clean up and the _____________________ the radiographic contrast.

A) better;higher
B) worse;lower
C) better;lower
D) worse;higher
سؤال
The number of lead lines per inch or centimeter is the grid:

A) number
B) ratio
C) frequency
D) rating
سؤال
The relationship between the height of the lead strips and the distance between them is the grid:

A) number
B) ratio
C) frequency
D) rating
سؤال
The material between the lead strips of a grid must be:

A) radiopaque
B) radiolucent
C) made of lead
D) made of tungsten
سؤال
The recommended SIDs that can be used with a focused grid is the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
سؤال
The distance between the grid and the convergent line is the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
سؤال
What is the grid ratio if the grid frequency is 100 lines/inch,and the lead strips are 1.8 mm high and 0.3 mm apart?

A) 5:1
B) 6:1
C) 8:1
D) 12:1
سؤال
An IR that has a grid permanently attached to its front surface is a:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
سؤال
The grid is located:

A) just below the x-ray tube window
B) between the patient and IR
C) just below the IR
D) none of the above
سؤال
Linear grids are the most commonly used because:

A) they are very inexpensive
B) the tube can be angled in all directions
C) the tube can be angled in the direction of the lead lines
D) all of the above
سؤال
Grids absorb scatter radiation because the scattered photons:

A) have high energy
B) have extremely low energy
C) travel in the same direction as the transmitted photons
D) travel at an angle to the transmitted photons
سؤال
A focused grid's lead strips are angled to match:

A) the anode angle
B) the angle of the x-rays in the primary beam
C) the angle of the scattered photons leaving the patient
D) the tube angulation
سؤال
What is the grid ratio if the lead strips are 2.4 mm high,0.03 mm wide,and 0.2 mm apart?

A) 5:1
B) 61
C) 8:1
D) 12:1
سؤال
The purpose of automatic collimation is:

A) improved image quality
B) limiting patient exposure
C) increasing the cost of equipment
D) none of the above
سؤال
A linear grid:

A) has lead strips that cross each other
B) has lead strips that travel in one direction
C) is the most common type of radiographic grid
D) B and C
سؤال
The location in space where all the lines extended from the lead strips meet is the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
سؤال
A grid with lead strips that run parallel to each other is a:

A) parallel grid
B) focused grid
C) nonfocused grid
D) A and C
سؤال
Grids are typically only used when the part measures more than ________ cm and ______ kVp is needed for the examination.

A) 5;50
B) 10;50
C) 10;60
D) 15;65
سؤال
Which of the following is the formula used to determine grid ratio?

A) Grid ratio = distance between the lead strips / height of the lead strips
B) Grid ratio = width of the lead strips / height of the lead strips
C) Grid ratio = height of the lead strips / distance between the lead strips
D) Grid ratio = height of the lead strips / width of the lead strips
سؤال
If all the convergent points were connected along the length of the grid they would form the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
سؤال
When the x-ray beam is angled across the lead strips you have _________ cutoff.

A) upside-down focused
B) off-level
C) off-center
D) off-focus
سؤال
The reason the grid in the bucky reciprocates is to:

A) absorb more scatter radiation
B) allow more transmitted radiation to reach the IR
C) blur out the grid lines
D) all of the above
سؤال
The grid is part of a device located just below the tabletop that also includes a tray to hold the IR.This device is the:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
سؤال
A short-dimension grid:

A) is typically used for most examinations
B) has lead strips running perpendicular to the long axis of the grid
C) has lead strips running parallel to the long axis of the grid
D) A and B
سؤال
If 24 mAs and a 6:1 grid results in an excellent radiograph,how much mAs is needed with a 5:1 grid?

A) 16 mAs
B) 20 mAs
C) 28.8 mAs
D) 36 mAs
سؤال
The formula for the grid conversion factor is:

A) GCF = mAs without grid / mAs with grid
B) GCF = mAs with grid - mAs without grid
C) GCF = mAs with grid / mAs without grid
D) GCF = mAs without grid - mAs with grid
سؤال
During the exposure,the grid in the bucky:

A) reciprocates
B) moves slightly from side to side
C) moves slightly from top to bottom
D) A and B
سؤال
The formula to use when changing from one grid to another is:

A) mAs₁/mAs₂ = GCF₂/GCF₁
B) mAs₁/mAs₂ = (GCF₂)²/GCF₁)²
C) mAs₁/mAs₂ = GCF₁/GCF₂
D) mAs₁/mAs₂ = (GCF₁)²/GCF₂)²
سؤال
Grid cutoff results in:

A) reduced exposure to the IR
B) a light film-screen image
C) possible quantum mottle
D) all of the above
سؤال
The type of grid that is usually taped to the front of an IR is the:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
سؤال
The cutoff that appears as a strip of appropriate density in the middle of the image and a significant loss of density on both sides is:

A) upside-down focused
B) off-level
C) off-center
D) off-focus
سؤال
If a tabletop exposure (no grid)of a humerus requires 2.5 mAs,how much mAs is needed if a 12:1 ratio grid is added?

A) 0.21 mAs
B) 0.5 mAs
C) 12.5 mAs
D) 30 mAs
سؤال
When the x-ray beam is not lined up with the center of the grid you have _________ cutoff.

A) upside-down focused
B) off-level
C) off-center
D) off-focus
سؤال
If 22 mAs and a 5:1 grid results in an excellent radiograph,how much mAs is needed with a 12:1 grid?

A) 8.8 mAs
B) 9.2 mAs
C) 52.8 mAs
D) 55 mAs
سؤال
When the SID is above or below the focal range you have _________ cutoff.

A) upside-down focused
B) off-level
C) off-center
D) off-focus
سؤال
The type of grid that includes a channel for the IR to slide into is the:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
سؤال
To compensate for the reduction of radiation reaching the IR when a grid is used,___________ is typically increased.

A) SID
B) kVp
C) mAs
D) OID
سؤال
Absorption of transmitted photons by a grid caused by misalignment is:

A) grid focus
B) grid reduction
C) grid cutoff
D) transmission reduction
سؤال
If a shoulder examination is done using an 8:1 ratio grid and 12 mAs,how much mAs should be used if the examination must be done tabletop (no grid)?

A) 1.5 mAs
B) 3 mAs
C) 48 mAs
D) 96 mAs
سؤال
To determine the amount of mAs to be increased when making grid changes,it is necessary to use the GCF,also known as the:

A) grid constancy figure
B) grid compensatory factor
C) general compensation factuals
D) grid conversion factor
سؤال
Scatter radiation is of no value in radiographic imaging.
سؤال
It is safe to assume that the x-ray beam field size and the light field size are exactly the same.
سؤال
When using automatic collimation,collimating to the anatomy of interest is an unnecessary waste of time;the beam is already collimated.
سؤال
The air gap technique reduces the amount of scatter radiation reaching the IR because:

A) more scatter is absorbed in the air
B) less scatter is produced in the patient
C) more scatter misses the IR
D) less scatter misses the IR
سؤال
Anyone in the room during an exposure must wear a lead apron to absorb the scatter radiation produced in the:

A) table
B) patient
C) air
D) beam
سؤال
The Moiré effect is also known as the _________ pattern.

A) cheetah
B) giraffe
C) lion
D) zebra
سؤال
The grid limits the amount of scatter radiation produced in the patient.
سؤال
Focused grids are more effective than parallel grids in absorbing scatter radiation and allowing transmitted radiation to reach the IR.
سؤال
Which of the following factors need to be considered when determining the grid to be used for a specific examination?

A) patient exposure
B) level of contrast improvement needed
C) focal range
D) all of the above
سؤال
Which of the following grids provides excellent scatter clean-up but requires close to perfect alignment to avoid cutoff?

A) 5:1 ratio grid
B) 8:1 ratio grid
C) 12:1 ratio grid
D) 16:1 ratio grid
سؤال
Adding a grid or increasing grid ratio results in an increase in patient dose.
سؤال
The air gap technique is based on creating a gap by increasing the ______.

A) SID
B) SOD
C) OID
D) all of the above
سؤال
The Moiré effect can be caused by:

A) using a grid with a frequency similar to the CR laser scanning frequency
B) using a focused grid upside down in the bucky
C) using a grid cassette in the bucky
D) A and C
سؤال
The grid used for the air gap technique should be high frequency.
سؤال
For a lateral lumbar spine,placing a lead shield on the table behind the area of exposure:

A) reduces the scatter exiting the patient
B) reduces the scatter reaching the IR
C) A and B
D) none of the above
سؤال
To compensate for some of the loss of recorded detail due to the large OID used with the air gap technique,the ________ should be increased as well.

A) grid ratio
B) SID
C) focal spot size
D) A and B
سؤال
Beam-restricting devices are located just above the tube housing.
سؤال
The only grid cutoff error that can occur with a parallel grid is:

A) upside-down focused
B) off-level
C) off-center
D) off-focus
سؤال
Grids absorb almost all of the scatter radiation and allow all of the transmitted photons to pass through to the IR.
سؤال
The air gap technique is a frequently used method for reducing the amount of scatter radiation reaching the IR.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/80
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 11: Scatter Control
1
Restriction of the primary beam to the anatomy of interest:

A) reduces patient exposure
B) is a major cause of repeated images
C) reduces the amount of scatter produced
D) A and C
A and C
2
The probability of a Compton interaction occurring is related to:

A) the energy of the x-ray photon
B) the atomic number of the matter
C) the mAs used
D) all of the above
the energy of the x-ray photon
3
When imaging the pelvis,changing from 14 × 17 collimation to 8 × 10 collimation requires:

A) an increase in kVp
B) a decrease in kVp
C) an increase in mAs
D) a decrease in mAs
an increase in mAs
4
The most effective and often used radiographic beam-restriction device is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
5
The flat piece of lead with a hole in it is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
6
The most easily adjusted radiographic beam-restricting device is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
7
The beam-restriction device that includes a visible light projecting the x-ray field size onto the patient is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
8
The field shape produced by a collimator is:

A) round
B) oval
C) rectangular
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
9
As compared with lower kVp exposures,when using high kVp the energy of the scattered photon is:

A) lower
B) higher
C) the same
D) half
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
10
A flat piece of lead with a hole in it that has a flange directed toward the patient is a(n):

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
11
Decreasing collimation (opening up the field size)results in:

A) increased scatter production and higher contrast
B) increased scatter production and lower contrast
C) decreased scatter production and higher contrast
D) decreased scatter production and lower contrast
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
12
The volume of tissue irradiated is determined by:

A) the area of collimation
B) patient thickness
C) field size
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
13
The beam-restriction device that results in images with the most unsharpness around the edge of the image is the:

A) aperture diaphragm
B) collimator
C) cone or cylinder
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
14
_____________________ collimation means _________________ field size.

A) decreasing;increasing
B) increasing;increasing
C) decreasing;decreasing
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
15
For radiographic procedures,scatter radiation is primarily the result of:

A) photoelectric interaction
B) pair production
C) Compton interaction
D) classical scattering
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
16
When there is significant collimation,the amount of radiation reaching the IR is:

A) reduced
B) increased
C) the same
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
17
The automatic collimator:

A) automatically collimates to the anatomy of interest
B) is required by law on all new equipment
C) is seldom found on modern x-ray equipment
D) automatically collimates to the IR size
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
18
The two major factors that affect the amount of scatter radiation produced and exiting the patient are:

A) kVp and mAs
B) volume of tissue irradiated and mAs
C) volume of tissue irradiated and kVp
D) kVp and the use of a grid
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
19
The unrestricted primary x-ray beam is:

A) round
B) oval
C) square
D) rectangular
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
20
Which of the following produces the greatest amount of scatter radiation exiting the patient?

A) low kVp and small field size
B) low kVp and large field size
C) high kVp and small field size
D) high kVp and large field size
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
21
The higher the grid ratio,the _____________ the scatter clean up and the _____________________ the radiographic contrast.

A) better;higher
B) worse;lower
C) better;lower
D) worse;higher
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
22
The number of lead lines per inch or centimeter is the grid:

A) number
B) ratio
C) frequency
D) rating
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
23
The relationship between the height of the lead strips and the distance between them is the grid:

A) number
B) ratio
C) frequency
D) rating
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
24
The material between the lead strips of a grid must be:

A) radiopaque
B) radiolucent
C) made of lead
D) made of tungsten
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
25
The recommended SIDs that can be used with a focused grid is the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
26
The distance between the grid and the convergent line is the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
27
What is the grid ratio if the grid frequency is 100 lines/inch,and the lead strips are 1.8 mm high and 0.3 mm apart?

A) 5:1
B) 6:1
C) 8:1
D) 12:1
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
28
An IR that has a grid permanently attached to its front surface is a:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
29
The grid is located:

A) just below the x-ray tube window
B) between the patient and IR
C) just below the IR
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
30
Linear grids are the most commonly used because:

A) they are very inexpensive
B) the tube can be angled in all directions
C) the tube can be angled in the direction of the lead lines
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
31
Grids absorb scatter radiation because the scattered photons:

A) have high energy
B) have extremely low energy
C) travel in the same direction as the transmitted photons
D) travel at an angle to the transmitted photons
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
32
A focused grid's lead strips are angled to match:

A) the anode angle
B) the angle of the x-rays in the primary beam
C) the angle of the scattered photons leaving the patient
D) the tube angulation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
33
What is the grid ratio if the lead strips are 2.4 mm high,0.03 mm wide,and 0.2 mm apart?

A) 5:1
B) 61
C) 8:1
D) 12:1
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
34
The purpose of automatic collimation is:

A) improved image quality
B) limiting patient exposure
C) increasing the cost of equipment
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
35
A linear grid:

A) has lead strips that cross each other
B) has lead strips that travel in one direction
C) is the most common type of radiographic grid
D) B and C
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
36
The location in space where all the lines extended from the lead strips meet is the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
37
A grid with lead strips that run parallel to each other is a:

A) parallel grid
B) focused grid
C) nonfocused grid
D) A and C
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
38
Grids are typically only used when the part measures more than ________ cm and ______ kVp is needed for the examination.

A) 5;50
B) 10;50
C) 10;60
D) 15;65
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
39
Which of the following is the formula used to determine grid ratio?

A) Grid ratio = distance between the lead strips / height of the lead strips
B) Grid ratio = width of the lead strips / height of the lead strips
C) Grid ratio = height of the lead strips / distance between the lead strips
D) Grid ratio = height of the lead strips / width of the lead strips
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
40
If all the convergent points were connected along the length of the grid they would form the:

A) convergent line
B) focal distance
C) convergent point
D) focal range
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
41
When the x-ray beam is angled across the lead strips you have _________ cutoff.

A) upside-down focused
B) off-level
C) off-center
D) off-focus
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
42
The reason the grid in the bucky reciprocates is to:

A) absorb more scatter radiation
B) allow more transmitted radiation to reach the IR
C) blur out the grid lines
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
43
The grid is part of a device located just below the tabletop that also includes a tray to hold the IR.This device is the:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
44
A short-dimension grid:

A) is typically used for most examinations
B) has lead strips running perpendicular to the long axis of the grid
C) has lead strips running parallel to the long axis of the grid
D) A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
45
If 24 mAs and a 6:1 grid results in an excellent radiograph,how much mAs is needed with a 5:1 grid?

A) 16 mAs
B) 20 mAs
C) 28.8 mAs
D) 36 mAs
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
46
The formula for the grid conversion factor is:

A) GCF = mAs without grid / mAs with grid
B) GCF = mAs with grid - mAs without grid
C) GCF = mAs with grid / mAs without grid
D) GCF = mAs without grid - mAs with grid
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
47
During the exposure,the grid in the bucky:

A) reciprocates
B) moves slightly from side to side
C) moves slightly from top to bottom
D) A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
48
The formula to use when changing from one grid to another is:

A) mAs₁/mAs₂ = GCF₂/GCF₁
B) mAs₁/mAs₂ = (GCF₂)²/GCF₁)²
C) mAs₁/mAs₂ = GCF₁/GCF₂
D) mAs₁/mAs₂ = (GCF₁)²/GCF₂)²
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
49
Grid cutoff results in:

A) reduced exposure to the IR
B) a light film-screen image
C) possible quantum mottle
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
50
The type of grid that is usually taped to the front of an IR is the:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
51
The cutoff that appears as a strip of appropriate density in the middle of the image and a significant loss of density on both sides is:

A) upside-down focused
B) off-level
C) off-center
D) off-focus
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
52
If a tabletop exposure (no grid)of a humerus requires 2.5 mAs,how much mAs is needed if a 12:1 ratio grid is added?

A) 0.21 mAs
B) 0.5 mAs
C) 12.5 mAs
D) 30 mAs
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
53
When the x-ray beam is not lined up with the center of the grid you have _________ cutoff.

A) upside-down focused
B) off-level
C) off-center
D) off-focus
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
54
If 22 mAs and a 5:1 grid results in an excellent radiograph,how much mAs is needed with a 12:1 grid?

A) 8.8 mAs
B) 9.2 mAs
C) 52.8 mAs
D) 55 mAs
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
55
When the SID is above or below the focal range you have _________ cutoff.

A) upside-down focused
B) off-level
C) off-center
D) off-focus
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
56
The type of grid that includes a channel for the IR to slide into is the:

A) wafer grid
B) bucky
C) grid cap
D) grid cassette
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
57
To compensate for the reduction of radiation reaching the IR when a grid is used,___________ is typically increased.

A) SID
B) kVp
C) mAs
D) OID
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
58
Absorption of transmitted photons by a grid caused by misalignment is:

A) grid focus
B) grid reduction
C) grid cutoff
D) transmission reduction
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
59
If a shoulder examination is done using an 8:1 ratio grid and 12 mAs,how much mAs should be used if the examination must be done tabletop (no grid)?

A) 1.5 mAs
B) 3 mAs
C) 48 mAs
D) 96 mAs
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
60
To determine the amount of mAs to be increased when making grid changes,it is necessary to use the GCF,also known as the:

A) grid constancy figure
B) grid compensatory factor
C) general compensation factuals
D) grid conversion factor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
61
Scatter radiation is of no value in radiographic imaging.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
62
It is safe to assume that the x-ray beam field size and the light field size are exactly the same.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
63
When using automatic collimation,collimating to the anatomy of interest is an unnecessary waste of time;the beam is already collimated.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
64
The air gap technique reduces the amount of scatter radiation reaching the IR because:

A) more scatter is absorbed in the air
B) less scatter is produced in the patient
C) more scatter misses the IR
D) less scatter misses the IR
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
65
Anyone in the room during an exposure must wear a lead apron to absorb the scatter radiation produced in the:

A) table
B) patient
C) air
D) beam
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
66
The Moiré effect is also known as the _________ pattern.

A) cheetah
B) giraffe
C) lion
D) zebra
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
67
The grid limits the amount of scatter radiation produced in the patient.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
68
Focused grids are more effective than parallel grids in absorbing scatter radiation and allowing transmitted radiation to reach the IR.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
69
Which of the following factors need to be considered when determining the grid to be used for a specific examination?

A) patient exposure
B) level of contrast improvement needed
C) focal range
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
70
Which of the following grids provides excellent scatter clean-up but requires close to perfect alignment to avoid cutoff?

A) 5:1 ratio grid
B) 8:1 ratio grid
C) 12:1 ratio grid
D) 16:1 ratio grid
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
71
Adding a grid or increasing grid ratio results in an increase in patient dose.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
72
The air gap technique is based on creating a gap by increasing the ______.

A) SID
B) SOD
C) OID
D) all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
73
The Moiré effect can be caused by:

A) using a grid with a frequency similar to the CR laser scanning frequency
B) using a focused grid upside down in the bucky
C) using a grid cassette in the bucky
D) A and C
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
74
The grid used for the air gap technique should be high frequency.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
75
For a lateral lumbar spine,placing a lead shield on the table behind the area of exposure:

A) reduces the scatter exiting the patient
B) reduces the scatter reaching the IR
C) A and B
D) none of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
76
To compensate for some of the loss of recorded detail due to the large OID used with the air gap technique,the ________ should be increased as well.

A) grid ratio
B) SID
C) focal spot size
D) A and B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
77
Beam-restricting devices are located just above the tube housing.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
78
The only grid cutoff error that can occur with a parallel grid is:

A) upside-down focused
B) off-level
C) off-center
D) off-focus
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
79
Grids absorb almost all of the scatter radiation and allow all of the transmitted photons to pass through to the IR.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
80
The air gap technique is a frequently used method for reducing the amount of scatter radiation reaching the IR.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 80 في هذه المجموعة.