Deck 18: Sterilization
1
Implantable items may be sterilized with EO gas.
True
Implants sterilized with EO should not be used until the results of biologic testing are known to be negative (minimum of 48 hours).
Implants sterilized with EO should not be used until the results of biologic testing are known to be negative (minimum of 48 hours).
2
A wet pack is acceptable to use as long as it is still sealed and has been sterilized.
False
Unless a wrapper is completely impermeable to water,a pack should be considered unsterile and unacceptable for use if it is wet.Reprocessing is necessary for a wet package or a load with one or more wet packages.
Unless a wrapper is completely impermeable to water,a pack should be considered unsterile and unacceptable for use if it is wet.Reprocessing is necessary for a wet package or a load with one or more wet packages.
3
____sterilization is the type of sterilization used when instruments are needed for immediate use.
A) Flash
B) Terminal
C) Aeration
D) Hydrogen peroxide
A) Flash
B) Terminal
C) Aeration
D) Hydrogen peroxide
A
Flash sterilization in a high-speed pressure sterilizer should be used only in urgent,unplanned,or emergency situations.
Flash sterilization in a high-speed pressure sterilizer should be used only in urgent,unplanned,or emergency situations.
4
A case cart system is used to gather and deliver sterile and nonsterile items needed for a particular surgical procedure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
5
When loading a dry heat sterilizer,it must be loaded to the fullest capacity with no space wasted so as to use the energy efficiently.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
6
When the sterilizer door is opened,wrapped instruments must be removed immediately to begin cooling and drying on a cool surface.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
7
Lubricant on any items must be removed before being sterilized with EO gas.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
8
When assembling instrument trays,sharp instruments should be placed on the bottom of the tray to prevent injury when removing instruments from the tray.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
9
A closed-container system with moisture in the closed tray is considered unsterile and contaminated.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
10
External indicator tape should be placed within an item's package to determine sterility.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
11
Concave or cupped instruments should be placed with the cupped side up so they catch and retain the excess water or solution at the end of the sterilization cycle.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
12
Which is a type of chemical sterilizing agent?
A) Steam
B) Microwave
C) Ozone gas
D) Radiation vapor
A) Steam
B) Microwave
C) Ozone gas
D) Radiation vapor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
13
Sterilization renders an item free of most microorganisms except for some spores.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
14
When using a gravity displacement sterilizer,the ability of the steam to kill the microorganisms is increased in direct proportion to the amount of air present.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
15
Routine maintenance consists of daily inspections of gaskets,gauges,and drain screens of sterilizing devices used.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
16
It is acceptable to open sterile supplies into a rigid closed container because the four sides are sterile.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
17
Ethylene oxide (EO)is a chemical sterilant that does not kill spores.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
18
Like EO sterilization,hydrogen peroxide sterilization requires a lengthy aeration period.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
19
If steam heat sterilization is being used,it is not necessary to wash and clean instruments before placing them into the sterilizer.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
20
A sterilized peel-pack pouch is considered sterile for only 30 days once it has been sterilized.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
21
Which is a requirement for the time an item has to spend in the sterilization cycle?
A) No more than two pieces of sterilization tape
B) Increased exposure to bioburden
C) Evacuation and dissipation of the sterilization agent
D) Lack of biologic indicator
A) No more than two pieces of sterilization tape
B) Increased exposure to bioburden
C) Evacuation and dissipation of the sterilization agent
D) Lack of biologic indicator
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
22
Which types of packaging materials are acceptable for use with EO sterilization?
A) Woven fabrics
B) Polyester
C) Polyvinyl chloride film
D) Nylon
A) Woven fabrics
B) Polyester
C) Polyvinyl chloride film
D) Nylon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
23
Dry heat sterilization is the preferred method of sterilization for which instruments?
A) Tissue scissors
B) Sweetheart retractor
C) Orthopedic mallet
D) Richardson retractor
A) Tissue scissors
B) Sweetheart retractor
C) Orthopedic mallet
D) Richardson retractor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
24
Which chemical sterilants require the user to wear personal protective equipment (PPE)throughout use of the product?
A) Glutaraldehyde
B) Steam sterilant
C) Nonionizing radiation
D) Cobalt-60
A) Glutaraldehyde
B) Steam sterilant
C) Nonionizing radiation
D) Cobalt-60
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
25
What is a reason not to use a flash sterilizer?
A) Routine sterilization of a tray
B) Urgent or unplanned situations
C) If an instrument has been dropped
D) For immediate use of an item
A) Routine sterilization of a tray
B) Urgent or unplanned situations
C) If an instrument has been dropped
D) For immediate use of an item
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
26
What is the preferred method for sterilizing talc?
A) Steam heat sterilization
B) Dry heat sterilization
C) EO gas sterilization
D) Glutaraldehyde sterilization
A) Steam heat sterilization
B) Dry heat sterilization
C) EO gas sterilization
D) Glutaraldehyde sterilization
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
27
Which is an advantage of EO gas sterilization?
A) It is noncorrosive and does not damage items.
B) It is a quick,efficient process.
C) It is inexpensive and cost effective.
D) It is nonirritating to mucous membranes.
A) It is noncorrosive and does not damage items.
B) It is a quick,efficient process.
C) It is inexpensive and cost effective.
D) It is nonirritating to mucous membranes.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
28
Which statement regarding irradiation sterilization is true?
A) The principal sources of ionizing radiation are water molecules and heat.
B) Ionizing radiation is the most effective sterilization method.
C) Irradiation cannot sterilize heat- and moisture-sensitive items.
D) Beta 45 is the most commonly used source for irradiation sterilization.
A) The principal sources of ionizing radiation are water molecules and heat.
B) Ionizing radiation is the most effective sterilization method.
C) Irradiation cannot sterilize heat- and moisture-sensitive items.
D) Beta 45 is the most commonly used source for irradiation sterilization.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
29
Most gravity displacement steam sterilizers have a minimum exposure time of ____ minutes.
A) 8 to 10
B) 15 to 30
C) 4
D) 15
A) 8 to 10
B) 15 to 30
C) 4
D) 15
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
30
What is the purpose of a load control number?
A) To determine which OR is being used for particular procedures
B) To determine the time the item or instrument tray is being used
C) To facilitate identification and retrieval of supplies if a sterilization failure occurs
D) To track which patient is being operated on within a facility
A) To determine which OR is being used for particular procedures
B) To determine the time the item or instrument tray is being used
C) To facilitate identification and retrieval of supplies if a sterilization failure occurs
D) To track which patient is being operated on within a facility
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
31
What is required for the steam sterilization process to be effective in killing microorganisms?
A) Cool sterile air and hydrogen peroxide
B) Pounds of pressure and heat
C) Moisture and heat
D) Air in sterilizer chamber
A) Cool sterile air and hydrogen peroxide
B) Pounds of pressure and heat
C) Moisture and heat
D) Air in sterilizer chamber
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
32
What is an advantage of using custom packs for a surgical procedure?
A) Reduces turnover time in opening supplies for a procedure
B) Provides many extra supplies within the pack from which the scrub nurse can choose
C) Increases inventory numbers
D) Requires additional inventory space
A) Reduces turnover time in opening supplies for a procedure
B) Provides many extra supplies within the pack from which the scrub nurse can choose
C) Increases inventory numbers
D) Requires additional inventory space
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
33
Which is one of the three known residual products found after EO sterilization?
A) Ethylene chloride.
B) Ethylene alcohol
C) Ethylene glycol.
D) Hydrogen peroxide
A) Ethylene chloride.
B) Ethylene alcohol
C) Ethylene glycol.
D) Hydrogen peroxide
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
34
What is the purpose of a Bowie-Dick test?
A) To determine the temperature of the sterilizer
B) To check for any residual microorganisms left in the sterilizer
C) To check for air entrapment in the prevacuum sterilizer
D) To determine whether the prevacuum sterilizer is cooling at the correct temperature
A) To determine the temperature of the sterilizer
B) To check for any residual microorganisms left in the sterilizer
C) To check for air entrapment in the prevacuum sterilizer
D) To determine whether the prevacuum sterilizer is cooling at the correct temperature
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
35
When preparing to sterilize odd-shaped or single instruments,which packaging material is best?
A) Nonwoven fabric
B) Peel-pack pouch
C) Wrapped tray
D) Foam and two-ply paper wrap
A) Nonwoven fabric
B) Peel-pack pouch
C) Wrapped tray
D) Foam and two-ply paper wrap
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
36
Which is a disadvantage of steam sterilization?
A) Steam leaves a harmful residue on instruments.
B) Items need to be clean and free of grease.
C) Steam is expensive and not easily supplied.
D) Steam's total time cycle is the longest of all methods.
A) Steam leaves a harmful residue on instruments.
B) Items need to be clean and free of grease.
C) Steam is expensive and not easily supplied.
D) Steam's total time cycle is the longest of all methods.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
37
What is an advantage of chemical sterilants?
A) Items don't need to be thoroughly rinsed before use.
B) They have low volatility.
C) They are absorbed by rubber and plastic.
D) Sterile transfer is easy.
A) Items don't need to be thoroughly rinsed before use.
B) They have low volatility.
C) They are absorbed by rubber and plastic.
D) Sterile transfer is easy.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
38
Which is one of the six process-associated parameters associated with sterilization?
A) Steam quality
B) Wrapper capacity
C) Cost to operate radiation sterilization
D) Saturation and penetration
A) Steam quality
B) Wrapper capacity
C) Cost to operate radiation sterilization
D) Saturation and penetration
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
39
Which is an advantage of using ozone gas sterilization?
A) Multiple settings for each cycle
B) Inexpensive cost per each load
C) High temperature heats instruments and sterilizes well
D) Can be used to sterilize implants and flexible endoscopes
A) Multiple settings for each cycle
B) Inexpensive cost per each load
C) High temperature heats instruments and sterilizes well
D) Can be used to sterilize implants and flexible endoscopes
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
40
In order to destroy prions,such as those in Creutzfeldt-Jakob disease,how long must they be sterilized?
A) Chemically sterilized for 10 minutes in Cavicide
B) Steam sterilized for a minimum of 1 hour at 270° F after soaking in sodium hydroxide for 1 hour
C) Soaked in ethylene oxide for at least 30 minutes,then dry heat sterilized for 10 minutes
D) Rinsing in sterile water at 240° F for 1 hour then rinsing in Cavicide
A) Chemically sterilized for 10 minutes in Cavicide
B) Steam sterilized for a minimum of 1 hour at 270° F after soaking in sodium hydroxide for 1 hour
C) Soaked in ethylene oxide for at least 30 minutes,then dry heat sterilized for 10 minutes
D) Rinsing in sterile water at 240° F for 1 hour then rinsing in Cavicide
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
41
Which class of chemical indicator is placed on the exterior of the package or item before processing?
A) Class 1
B) Class 3
C) Class 4
D) Class 5
A) Class 1
B) Class 3
C) Class 4
D) Class 5
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck
42
What method assures that sterilization conditions have been achieved during the steam sterilization process?
A) Bowie-Dick test
B) Negative biologic control
C) Negative biologic indicator
D) Class 2 auto test
A) Bowie-Dick test
B) Negative biologic control
C) Negative biologic indicator
D) Class 2 auto test
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 42 في هذه المجموعة.
فتح الحزمة
k this deck