Deck 33: Automatic Exposure Controls

ملء الشاشة (f)
exit full mode
سؤال
When an AEC is used for an AP hip, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the left outer cell only
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Most AEC consoles permit activation of

A)all three cells simultaneously.
B)all three cells in any combination.
C)the outer cells when the center cell is inactivated.
D)the center cell and either outer cell.
سؤال
When an AEC is used for an AP abdomen, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the left outer cell only
سؤال
Contemporary AEC systems work on the x-ray property

A)causing certain crystals to fluoresce.
B)causing ionization of gases.
C)of producing small amounts of heat as they pass through matter.
D)affecting photographic film.
سؤال
Early versions of AEC technology were referred to as

A)photometers.
B)phototimers.
C)photosensors.
D)voltage regulators.
سؤال
The backup time of most AECs is set at ____ of the anticipated manual exposure time.

A)10%
B)50%
C)100%
D)150%
سؤال
When more than one ionization chamber is used, the signal is

A)averaged.
B)muted.
C)multiplied.
D)all of the above
سؤال
A radiographer is performing an AP knee radiograph using AEC.The manual technique for this exam would be 12 mAs at 80 kVp.The backup mAs the radiographer should set would be

A)6 mAs.
B)12 mAs.
C)18 mAs.
D)24 mAs.
سؤال
When an AEC is used for a PA chest, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the right outer cell only
سؤال
The single function of an AEC is to eliminate the need to set

A)kVp.
B)mA.
C)time.
D)all of the above
سؤال
When an AEC is used for an AP lumbar spine, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the right outer cell only
سؤال
When using an AEC, the radiographer loses control of

A)distance.
B)mA.
C)kVp.
D)mAs.
سؤال
As you are performing a KUB radiograph on a patient using AEC, you notice that your post-exposure readout is unusually high.A possible explanation for this high reading could be

A)the kVp was too high.
B)the backup mAs was set too low.
C)a detector was collimated out of the field of exposure.
D)the minimum response time was too long.
سؤال
In the event that the mAs needed for a small anatomical structure is very small, in order to ensure the AEC terminates the exposure correctly,

A)the kVp should be increased.
B)the mA should be decreased.
C)all three detectors should activated.
D)the large focal spot should be used.
سؤال
U.S.public law requires that generators automatically terminate AEC exposures at ____ mAs above 50 kVp.

A)100
B)300
C)600
D)900
سؤال
Ionization chamber AECs are usually used in a ____ chamber configuration.

A)one-
B)two-
C)three-
D)four-
سؤال
Automatic exposure devices provide a diagnostic quality radiograph when the

A)anatomy of interest is positioned directly above the appropriate ionization chambers.
B)proper time is set.
C)correct focal spot is selected.
D)beam filtration is minimum.
سؤال
The most common configuration includes

A)three chambers.
B)a center chamber at the center of the image receptor.
C)the left and right chambers slightly higher and lateral.
D)all of the above
سؤال
If the primary beam is collimated from an activated chamber, the result is a

A)light radiograph.
B)dark radiograph.
C)short exposure time.
D)decrease in radiographic density.
سؤال
When an AEC is used for a lateral chest, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the left outer cell only
سؤال
Match the following choices with the correct statement as each is related to automatic exposure control technology.
-1, -2, 0, +1, +2

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
سؤال
When performing a follow-up abdomen image on a patient who recently had a small bowel study, it may be best to

A)deactivate the AEC and set the technique manually.
B)dramatically increase the backup mAs.
C)increase the minimum response time.
D)increase to 120 kVp.
سؤال
When using APR for a radiographic exposure,

A)AEC may be turned off manually.
B)a backup mAs is already set.
C)programmed AEC chamber selections may be reconfigured.
D)all of the above
سؤال
Match the following choices with the correct statement as each is related to automatic exposure control technology.
AP hip

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
سؤال
Match the following choices with the correct statement as each is related to automatic exposure control technology.
typically 0.001 sec

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
سؤال
Match the following choices with the correct statement as each is related to automatic exposure control technology.
Older technologists may still refer to it.

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
سؤال
Match the following choices with the correct statement as each is related to automatic exposure control technology.
AP abdomen radiograph

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
سؤال
AEC density controls are properly used to

A)compensate for patient thickness.
B)balance the AEC detectors.
C)compensate for asymmetrical pathology.
D)compensate for improper positioning.
سؤال
Most modern AEC systems provide a minimum response time of

A)1 millisecond.
B).001 sec.
C)1/1000 sec.
D)all of the above
سؤال
A new high frequency radiographic system is being released to a customer for first clinical use.The applications person states that the AEC density controls are in 20% increments.If a normal AEC exposure of the hip is 24 mAs, a repeat exposure at +2 would yield a mAs value of

A)26 mAs.
B)29 mAs.
C)34 mAs.
D)48 mAs.
سؤال
Match the following choices with the correct statement as each is related to automatic exposure control technology.
+2 used when N would have been optimum

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/31
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 33: Automatic Exposure Controls
1
When an AEC is used for an AP hip, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the left outer cell only
the center cell
2
Most AEC consoles permit activation of

A)all three cells simultaneously.
B)all three cells in any combination.
C)the outer cells when the center cell is inactivated.
D)the center cell and either outer cell.
all three cells in any combination.
3
When an AEC is used for an AP abdomen, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the left outer cell only
all three cells
4
Contemporary AEC systems work on the x-ray property

A)causing certain crystals to fluoresce.
B)causing ionization of gases.
C)of producing small amounts of heat as they pass through matter.
D)affecting photographic film.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
5
Early versions of AEC technology were referred to as

A)photometers.
B)phototimers.
C)photosensors.
D)voltage regulators.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
6
The backup time of most AECs is set at ____ of the anticipated manual exposure time.

A)10%
B)50%
C)100%
D)150%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
7
When more than one ionization chamber is used, the signal is

A)averaged.
B)muted.
C)multiplied.
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
8
A radiographer is performing an AP knee radiograph using AEC.The manual technique for this exam would be 12 mAs at 80 kVp.The backup mAs the radiographer should set would be

A)6 mAs.
B)12 mAs.
C)18 mAs.
D)24 mAs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
9
When an AEC is used for a PA chest, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the right outer cell only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
10
The single function of an AEC is to eliminate the need to set

A)kVp.
B)mA.
C)time.
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
11
When an AEC is used for an AP lumbar spine, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the right outer cell only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
12
When using an AEC, the radiographer loses control of

A)distance.
B)mA.
C)kVp.
D)mAs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
13
As you are performing a KUB radiograph on a patient using AEC, you notice that your post-exposure readout is unusually high.A possible explanation for this high reading could be

A)the kVp was too high.
B)the backup mAs was set too low.
C)a detector was collimated out of the field of exposure.
D)the minimum response time was too long.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
14
In the event that the mAs needed for a small anatomical structure is very small, in order to ensure the AEC terminates the exposure correctly,

A)the kVp should be increased.
B)the mA should be decreased.
C)all three detectors should activated.
D)the large focal spot should be used.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
15
U.S.public law requires that generators automatically terminate AEC exposures at ____ mAs above 50 kVp.

A)100
B)300
C)600
D)900
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
16
Ionization chamber AECs are usually used in a ____ chamber configuration.

A)one-
B)two-
C)three-
D)four-
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
17
Automatic exposure devices provide a diagnostic quality radiograph when the

A)anatomy of interest is positioned directly above the appropriate ionization chambers.
B)proper time is set.
C)correct focal spot is selected.
D)beam filtration is minimum.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
18
The most common configuration includes

A)three chambers.
B)a center chamber at the center of the image receptor.
C)the left and right chambers slightly higher and lateral.
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
19
If the primary beam is collimated from an activated chamber, the result is a

A)light radiograph.
B)dark radiograph.
C)short exposure time.
D)decrease in radiographic density.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
20
When an AEC is used for a lateral chest, which ionization chambers are utilized?

A)the center cell
B)the left and right outer cells
C)all three cells
D)the left outer cell only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
21
Match the following choices with the correct statement as each is related to automatic exposure control technology.
-1, -2, 0, +1, +2

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
22
When performing a follow-up abdomen image on a patient who recently had a small bowel study, it may be best to

A)deactivate the AEC and set the technique manually.
B)dramatically increase the backup mAs.
C)increase the minimum response time.
D)increase to 120 kVp.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
23
When using APR for a radiographic exposure,

A)AEC may be turned off manually.
B)a backup mAs is already set.
C)programmed AEC chamber selections may be reconfigured.
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
24
Match the following choices with the correct statement as each is related to automatic exposure control technology.
AP hip

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
25
Match the following choices with the correct statement as each is related to automatic exposure control technology.
typically 0.001 sec

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
26
Match the following choices with the correct statement as each is related to automatic exposure control technology.
Older technologists may still refer to it.

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
27
Match the following choices with the correct statement as each is related to automatic exposure control technology.
AP abdomen radiograph

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
28
AEC density controls are properly used to

A)compensate for patient thickness.
B)balance the AEC detectors.
C)compensate for asymmetrical pathology.
D)compensate for improper positioning.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
29
Most modern AEC systems provide a minimum response time of

A)1 millisecond.
B).001 sec.
C)1/1000 sec.
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
30
A new high frequency radiographic system is being released to a customer for first clinical use.The applications person states that the AEC density controls are in 20% increments.If a normal AEC exposure of the hip is 24 mAs, a repeat exposure at +2 would yield a mAs value of

A)26 mAs.
B)29 mAs.
C)34 mAs.
D)48 mAs.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
31
Match the following choices with the correct statement as each is related to automatic exposure control technology.
+2 used when N would have been optimum

A)phototiming
B)minimum response time
C)backup mAs
D)underexposed image
E)overexposed image
F)density controls
G)all three detectors
H)center detector only
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 31 في هذه المجموعة.