Deck 6: The X-Ray Tube

ملء الشاشة (f)
exit full mode
سؤال
The focusing cup has a/an ____ charge.

A)neutral
B)atomic
C)positive
D)negative
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Pitting of the anode commonly occurs

A)when the unit is not warmed up properly.
B)when the anode is off-focus.
C)with extended use.
D)when the kilovoltage is too high.
سؤال
All of the following are related except one.Select the one that is NOT RELATED.

A)a source of electrons
B)a vacuum
C)thermionic emission
D)a large potential difference
سؤال
A filament may break due to

A)evaporation.
B)deposition.
C)increased sensitivity.
D)vaporization.
سؤال
Filament materials are chosen primarily for their

A)atomic number.
B)high melting points.
C)ability to vaporize easily.
D)high boiling points.
سؤال
Melting of the anode commonly occurs

A)when the unit is not warmed up properly.
B)with extended use.
C)when the kilovoltage is too high.
D)when the stator fails and the rotor ceases to turn.
سؤال
In order to time the x-ray exposure with rapid inspiration on an infant,

A)three phase generators are preferred.
B)the exposure button and prep are pressed simultaneously.
C)exposure may be initiated as fast a 0.10 sec.
D)less expensive single-phase generators are desirable.
سؤال
X-ray photon production occurs at the

A)anode.
B)cathode.
C)filament.
D)stator.
سؤال
As more and more electrons build up in the area of the filament, their negative charges oppose the emission of additional electrons.This phenomenon is known as

A)thermionic emission.
B)biased cloud formation.
C)space charge effect.
D)current saturation.
سؤال
The function of the cathode is to produce

A)a focal point.
B)an electrical connection to the rectifier.
C)a thermionic cloud.
D)a grounding effect.
سؤال
The area of the focal spot that is projected out of the tube toward the object being radiographed is the

A)effective focal spot.
B)line focus.
C)actual focal spot.
D)x-ray tube long axis.
سؤال
All of the following are preferred cathode filament materials EXCEPT

A)copper.
B)tungsten.
C)rhenium.
D)molybdenum.
سؤال
The physical area of a rotating anode focal track, affected by the cathode electron beam, is the

A)effective focal spot.
B)effective focal track.
C)actual focal spot.
D)projected focal track.
سؤال
Which of the following would affect the production of a thermionic cloud?

A)filament diameter
B)filament length
C)filament temperature
D)all of the above
سؤال
Cracking of the anode typically occurs

A)with extended use.
B)when the anode is off-focus.
C)when a cold anode is hit with a high kVp exposure.
D)when the cathode cup touches the anode, causing a short.
سؤال
The exact point on the anode where the x-ray beam emanates is the

A)focusing cup.
B)focal spot.
C)stator.
D)rotor.
سؤال
Driving the thermionic cloud from the cathode to the anode requires

A)a grid biased anode.
B)a small voltage.
C)a large amperage.
D)a small amperage.
سؤال
The actual focal spot is controlled by the

A)thickness of the anode disc.
B)length of the filament.
C)anode rotation speed.
D)angle of the cathode focusing cup.
سؤال
All of the following are part of the cathode assembly EXCEPT

A)filament.
B)stator.
C)focusing cup.
D)associated wiring.
سؤال
Tungsten is the metal of choice for the source of x-ray photons because of its

A)high atomic number.
B)low melting point.
C)low mass number.
D)low cost.
سؤال
The most common diagnostic radiography target angle is ____ degrees.

A)12
B)24
C)45
D)54
سؤال
The protective housing controls leakage and scatter radiation through

A)evaporation.
B)vaporization.
C)absorption.
D)condensation.
سؤال
List the three functions of the x-ray tube anode.
سؤال
What is the function of the filament?
سؤال
When radiographing a wedge-shaped anatomical structure such as the femur, the thicker portion of the anatomy should be positioned

A)under the cathode end of the tube.
B)in the exact center of the beam. as it is most intense in the center.
C)off center laterally to negate the heel effect.
D)under the anode side of the tube.
سؤال
To determine the allowable combination of exposures factors, thus preventing x-ray tube damage,

A)a tube rating chart is referenced after exposure to check correctness.
B)the automatic exposure circuit is activated.
C)an x-ray tube rating chart is checked prior to exposure.
D)an anode cooling chart is referenced prior to exposure.
سؤال
List the three parts of the anode assembly.
سؤال
As the angle of the anode increases and the incident electron beam size remains the same, the effective focal spot size

A)increases.
B)decreases.
C)remains the same.
D)cannot be determined.
سؤال
To cover a 14 in.x 17 ft field at 40 ft, a ____-degree target angle is required.

A)3
B)5
C)7
D)12
سؤال
As the actual focal spot size increases, the effective focal spot size

A)increases.
B)decreases.
C)remains the same.
D)cannot be determined.
سؤال
The function of the stator and rotor assembly is to

A)create a vacuum.
B)rotate the anode.
C)insulate the anode.
D)disrupt the electromagnets of the induction motor.
سؤال
Leakage radiation from the lead-lined housing must not exceed

A)10 mR/hr measured at 40 inches.
B)100 mR/min measured at 36 inches.
C)10 mR/min measured at the tube head.
D)100 mR/hr measured at 1 meter.
سؤال
The problem of off-focus radiation

A)is particularly important with digital detectors.
B)distorts the digital histogram.
C)may result in suboptimum digital images.
D)all of the above
سؤال
Insulation of the high-voltage components of the tube and absorption of the heat produced by x-ray production is achieved through the use of

A)a small fan.
B)a vacuum.
C)a stator.
D)dielectric oil.
سؤال
The rotor is located ____ the stator and ____ the envelope.

A)inside; inside
B)inside; outside
C)outside; outside
D)outside; inside
سؤال
The use of the line-focus principle causes a problem known as the ____ effect.

A)space charge
B)quantum mottle
C)anode heel
D)saturation current
سؤال
In which direction should the anode be placed for an AP projection of the femur?
سؤال
The only portion of the anode assembly placed outside the vacuum of the envelope is the

A)stator.
B)rotor.
C)rotating disc.
D)molybdenum neck.
سؤال
List two other names for the anode target.
سؤال
What type of radiation is composed of photons not produced at the actual focal spot?

A)off-focus
B)extrafocal
C)both a and b
D)primary
سؤال
How many heat units are generated by an exposure of 70 kVp, 300 mA, and 0.1 second on a 1 ϕ\phi rectified unit?
سؤال
Using the following exposures factors on a high-frequency generator, how many joules of electrical energy are being created
400 mA
95 kVp
26 ms
سؤال
How many heat units are generated by three (3) exposures of 100 kVp, 400 mA, and 0.01 second using a high frequency generator?
سؤال
How many heat units are generated by an exposure of 70 kVp, 400 mA, and 0.1 second on a 3 ϕ\phi rectified unit?
سؤال
List the three primary functions of the x-ray tube's protective housing.
سؤال
A conscientious technologist will always handle the x-ray tube assembly with care, particularly when the x-ray tube has been used for high mAs and kVp exposures over a short period of time.Technologists are cautioned about moving the x-ray tube assembly quickly and with "jerking" movements.Explain why this is important to remember.
سؤال
The use of stress-relief anodes is effective at dealing with what inherent characteristic(s) of x-ray production?
سؤال
Why is a vacuum created in the x-ray tube?
سؤال
How many heat units are generated by an exposure of 100 kVp, 400 mA, and 0.01 second on a high-frequency unit?
سؤال
Metal envelope x-ray tubes are gaining in popularity.Explain some key advantages to a metal housing x-ray tube.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/50
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 6: The X-Ray Tube
1
The focusing cup has a/an ____ charge.

A)neutral
B)atomic
C)positive
D)negative
negative
2
Pitting of the anode commonly occurs

A)when the unit is not warmed up properly.
B)when the anode is off-focus.
C)with extended use.
D)when the kilovoltage is too high.
with extended use.
3
All of the following are related except one.Select the one that is NOT RELATED.

A)a source of electrons
B)a vacuum
C)thermionic emission
D)a large potential difference
thermionic emission
4
A filament may break due to

A)evaporation.
B)deposition.
C)increased sensitivity.
D)vaporization.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
5
Filament materials are chosen primarily for their

A)atomic number.
B)high melting points.
C)ability to vaporize easily.
D)high boiling points.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
6
Melting of the anode commonly occurs

A)when the unit is not warmed up properly.
B)with extended use.
C)when the kilovoltage is too high.
D)when the stator fails and the rotor ceases to turn.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
7
In order to time the x-ray exposure with rapid inspiration on an infant,

A)three phase generators are preferred.
B)the exposure button and prep are pressed simultaneously.
C)exposure may be initiated as fast a 0.10 sec.
D)less expensive single-phase generators are desirable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
8
X-ray photon production occurs at the

A)anode.
B)cathode.
C)filament.
D)stator.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
9
As more and more electrons build up in the area of the filament, their negative charges oppose the emission of additional electrons.This phenomenon is known as

A)thermionic emission.
B)biased cloud formation.
C)space charge effect.
D)current saturation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
10
The function of the cathode is to produce

A)a focal point.
B)an electrical connection to the rectifier.
C)a thermionic cloud.
D)a grounding effect.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
11
The area of the focal spot that is projected out of the tube toward the object being radiographed is the

A)effective focal spot.
B)line focus.
C)actual focal spot.
D)x-ray tube long axis.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
12
All of the following are preferred cathode filament materials EXCEPT

A)copper.
B)tungsten.
C)rhenium.
D)molybdenum.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
13
The physical area of a rotating anode focal track, affected by the cathode electron beam, is the

A)effective focal spot.
B)effective focal track.
C)actual focal spot.
D)projected focal track.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
14
Which of the following would affect the production of a thermionic cloud?

A)filament diameter
B)filament length
C)filament temperature
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
15
Cracking of the anode typically occurs

A)with extended use.
B)when the anode is off-focus.
C)when a cold anode is hit with a high kVp exposure.
D)when the cathode cup touches the anode, causing a short.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
16
The exact point on the anode where the x-ray beam emanates is the

A)focusing cup.
B)focal spot.
C)stator.
D)rotor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
17
Driving the thermionic cloud from the cathode to the anode requires

A)a grid biased anode.
B)a small voltage.
C)a large amperage.
D)a small amperage.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
18
The actual focal spot is controlled by the

A)thickness of the anode disc.
B)length of the filament.
C)anode rotation speed.
D)angle of the cathode focusing cup.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
19
All of the following are part of the cathode assembly EXCEPT

A)filament.
B)stator.
C)focusing cup.
D)associated wiring.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
20
Tungsten is the metal of choice for the source of x-ray photons because of its

A)high atomic number.
B)low melting point.
C)low mass number.
D)low cost.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
21
The most common diagnostic radiography target angle is ____ degrees.

A)12
B)24
C)45
D)54
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
22
The protective housing controls leakage and scatter radiation through

A)evaporation.
B)vaporization.
C)absorption.
D)condensation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
23
List the three functions of the x-ray tube anode.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
24
What is the function of the filament?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
25
When radiographing a wedge-shaped anatomical structure such as the femur, the thicker portion of the anatomy should be positioned

A)under the cathode end of the tube.
B)in the exact center of the beam. as it is most intense in the center.
C)off center laterally to negate the heel effect.
D)under the anode side of the tube.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
26
To determine the allowable combination of exposures factors, thus preventing x-ray tube damage,

A)a tube rating chart is referenced after exposure to check correctness.
B)the automatic exposure circuit is activated.
C)an x-ray tube rating chart is checked prior to exposure.
D)an anode cooling chart is referenced prior to exposure.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
27
List the three parts of the anode assembly.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
28
As the angle of the anode increases and the incident electron beam size remains the same, the effective focal spot size

A)increases.
B)decreases.
C)remains the same.
D)cannot be determined.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
29
To cover a 14 in.x 17 ft field at 40 ft, a ____-degree target angle is required.

A)3
B)5
C)7
D)12
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
30
As the actual focal spot size increases, the effective focal spot size

A)increases.
B)decreases.
C)remains the same.
D)cannot be determined.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
31
The function of the stator and rotor assembly is to

A)create a vacuum.
B)rotate the anode.
C)insulate the anode.
D)disrupt the electromagnets of the induction motor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
32
Leakage radiation from the lead-lined housing must not exceed

A)10 mR/hr measured at 40 inches.
B)100 mR/min measured at 36 inches.
C)10 mR/min measured at the tube head.
D)100 mR/hr measured at 1 meter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
33
The problem of off-focus radiation

A)is particularly important with digital detectors.
B)distorts the digital histogram.
C)may result in suboptimum digital images.
D)all of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
34
Insulation of the high-voltage components of the tube and absorption of the heat produced by x-ray production is achieved through the use of

A)a small fan.
B)a vacuum.
C)a stator.
D)dielectric oil.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
35
The rotor is located ____ the stator and ____ the envelope.

A)inside; inside
B)inside; outside
C)outside; outside
D)outside; inside
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
36
The use of the line-focus principle causes a problem known as the ____ effect.

A)space charge
B)quantum mottle
C)anode heel
D)saturation current
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
37
In which direction should the anode be placed for an AP projection of the femur?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
38
The only portion of the anode assembly placed outside the vacuum of the envelope is the

A)stator.
B)rotor.
C)rotating disc.
D)molybdenum neck.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
39
List two other names for the anode target.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
40
What type of radiation is composed of photons not produced at the actual focal spot?

A)off-focus
B)extrafocal
C)both a and b
D)primary
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
41
How many heat units are generated by an exposure of 70 kVp, 300 mA, and 0.1 second on a 1 ϕ\phi rectified unit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
42
Using the following exposures factors on a high-frequency generator, how many joules of electrical energy are being created
400 mA
95 kVp
26 ms
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
43
How many heat units are generated by three (3) exposures of 100 kVp, 400 mA, and 0.01 second using a high frequency generator?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
44
How many heat units are generated by an exposure of 70 kVp, 400 mA, and 0.1 second on a 3 ϕ\phi rectified unit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
45
List the three primary functions of the x-ray tube's protective housing.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
46
A conscientious technologist will always handle the x-ray tube assembly with care, particularly when the x-ray tube has been used for high mAs and kVp exposures over a short period of time.Technologists are cautioned about moving the x-ray tube assembly quickly and with "jerking" movements.Explain why this is important to remember.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
47
The use of stress-relief anodes is effective at dealing with what inherent characteristic(s) of x-ray production?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
48
Why is a vacuum created in the x-ray tube?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
49
How many heat units are generated by an exposure of 100 kVp, 400 mA, and 0.01 second on a high-frequency unit?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
50
Metal envelope x-ray tubes are gaining in popularity.Explain some key advantages to a metal housing x-ray tube.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 50 في هذه المجموعة.